Thoracic CT technique in children

被引:27
作者
Brody, AS [1 ]
机构
[1] Childrens Hosp, Med Ctr, Dept Radiol CH1, Cincinnati, OH 45229 USA
关键词
CT-technique; pediatric-radiation risk;
D O I
10.1097/00005382-200110000-00007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Computed tomography (CT) is a powerful tool for imaging the different structures of the child's thorax. Pediatric thoracic CT technique should provide images that allow confident diagnosis at the lowest risk to the patient. New data has increased our understanding of the risk of low-dose radiation. Understanding the technical aspects of CT scanning allows the CT scanner to be optimized for the best combination of image quality and radiation dose. Developments in CT scanning, including multidetector scanners and vascular imaging techniques, are changing the way CT scanning is used. The many imaging options available to the thoracic radiologist require a complex set of decisions when establishing CT protocols and when selecting techniques for different clinical indications. This article presents information on radiation risk and provides an overview of the broad range of factors used when performing pediatric thoracic CT.
引用
收藏
页码:259 / 268
页数:10
相关论文
共 49 条
[1]   Sedation procedures in MR imaging: Safety, effectiveness, and nursing effect on examinations [J].
Bluemke, DA ;
Breiter, SN .
RADIOLOGY, 2000, 216 (03) :645-652
[2]   Estimated risks of radiation-induced fatal cancer from pediatric CT [J].
Brenner, DJ ;
Elliston, CD ;
Hall, EJ ;
Berdon, WE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :289-296
[3]   ALIASING - SOURCE OF STREAKS IN COMPUTED TOMOGRAMS [J].
BROOKS, RA ;
GLOVER, GH ;
TALBERT, AJ ;
EISNER, RL ;
DIBIANCA, FA .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1979, 3 (04) :511-518
[4]  
CASSESE J, 2000, SOC PED RAD SPR NAPL
[5]   The use of oral pentobarbital sodium (Nembutal) versus oral chloral hydrate in infants undergoing CT and MR imaging - a pilot study [J].
Chung, T ;
Hoffer, FA ;
Connor, L ;
Zurakowski, D ;
Burrows, PE .
PEDIATRIC RADIOLOGY, 2000, 30 (05) :332-335
[6]   Detection of pulmonary metastases with pathological correlation: effect of breathing on the accuracy of spiral CT [J].
Coakley, FV ;
Cohen, MD ;
Waters, DJ ;
Davis, MM ;
Karmazyn, B ;
Gonin, R ;
Hanna, MP .
PEDIATRIC RADIOLOGY, 1997, 27 (07) :576-579
[7]  
COTE CJ, 1994, PEDIATR CLIN N AM, V41, P31
[8]   COMPARISON OF HELICAL AND CONVENTIONAL CHEST CT IN THE UNCOOPERATIVE PEDIATRIC-PATIENT [J].
COX, TD ;
WHITE, KS ;
WEINBERGER, E ;
EFFMANN, EL .
PEDIATRIC RADIOLOGY, 1995, 25 (05) :347-349
[9]  
CRIST WM, 1996, NELSON TXB PEDIAT, P1452
[10]   Detection of pulmonary nodules with overlapping vs non-overlapping image reconstruction at spiral CT [J].
Diederich, S ;
Lentschig, MG ;
Winter, F ;
Roos, N ;
Bongartz, G .
EUROPEAN RADIOLOGY, 1999, 9 (02) :281-286