摘要
Reducing and continuously varying the flip angle of the refocusing RF pulses in a rapid acquisition with relaxation enhancement (RARE; fast/turbo spin echo) sequence is a useful means of addressing high RF power deposition and modulation transfer function (MTF) distortion due to relaxation. This work presents a streamlined technique to generate a sequence of refocusing flip angles on a per-prescription basis that produces relatively high SNR and limits blurring in a wide range of materials encountered in vivo. Since the "effective TV (traditionally defined as the time at which the center of k-space is sampled) no longer corresponds to the expected amount of spin-echo T-2 contrast due to the mixing of stimulated and spin echoes, a "contrast-equivalent" TE is defined and experimentally demonstrated that allows annotation of a more accurate effective TE that matches the contrast produced by 180 degrees refocusing. Furthermore, contrast is shown to be manipulable by the addition of magnetization preparation pulse sequence segments, such as T-2-prep, to produce clinically desirable contrast for routine head and body imaging.
引用
收藏
页码:1030 / 1037
页数:8
相关论文
共 14 条
[1]   The sensitivity of low flip angle RARE imaging [J].
Alsop, DC .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (02) :176-184
[2]   CORONARY ANGIOGRAPHY WITH MAGNETIZATION-PREPARED T-2 CONTRAST [J].
BRITTAIN, JH ;
HU, BS ;
WRIGHT, GA ;
MEYER, CH ;
MACOVSKI, A ;
NISHIMURA, DG .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :689-696
[3]   Fast spin echo sequences with very long echo trains:: Design of variable refocusing flip angle schedules and generation of clinical T2 contrast [J].
Busse, RF ;
Hariharan, H ;
Vu, A ;
Brittain, JH .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (05) :1030-1037
[4]   Reduced RF power without blurring: Correcting for modulation of refocusing flip angle in FSE sequences [J].
Busse, RF .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (05) :1031-1037
[5]  
BUSSE RF, 2001, P 9 ANN M ISMRM GLAS, P1790
[6]  
BUSSE RF, 2003, P 11 ANN M ISMRM TOR, P206
[7]  
GLOVER G, 1991, P 10 ANN M SMRM SAN, P1242
[8]   Calculation of flip angles for echo trains with predefined amplitudes with the extended phase graph (EPG)-algorithm: Principles and applications to hyperecho and TRAPS sequences [J].
Hennig, J ;
Weigel, M ;
Scheffler, K .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (01) :68-80
[9]   Multiecho sequences with variable refocusing flip angles: Optimization of signal behavior using smooth transitions between pseudo steady states (TRAPS) [J].
Hennig, J ;
Weigel, M ;
Scheffler, K .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (03) :527-535
[10]   MULTIECHO IMAGING SEQUENCES WITH LOW REFOCUSING FLIP ANGLES [J].
HENNIG, J .
JOURNAL OF MAGNETIC RESONANCE, 1988, 78 (03) :397-407