High-resolution transmission electron microscopy using negative spherical aberration

被引:143
作者
Jia, CL [1 ]
Lentzen, M [1 ]
Urban, K [1 ]
机构
[1] Forschungszentrum Julich GMBH, Inst Festkorperforsch, D-52425 Julich, Germany
关键词
aberration correction; spherical aberration; atomic resolution imaging; contrast theory; oxygen imaging; defects in electroceramics;
D O I
10.1017/S1431927604040425
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A novel imaging mode for high-resolution transmission electron microscopy is described. It is based on the adjustment of a negative value of the spherical aberration C-S of the objective lens of a transmission electron microscope equipped with a multipole aberration corrector system. Negative spherical aberration applied together with an overfocus yields high-resolution images with bright-atom contrast. Compared to all kinds of images taken in conventional transmission electron microscopes, where the then unavoidable positive spherical aberration is combined with an underfocus, the contrast is dramatically increased. This effect can only be understood on the basis of a full nonlinear imaging theory. Calculations show that the nonlinear contrast contributions diminish the image contrast relative to the linear image for a positive-C-S setting whereas they reinforce the image contrast relative to the linear image for a negative-C-S setting. The application of the new mode to the imaging of oxygen in SrTiO3 and YBa2Cu3O7 demonstrates the benefit to materials science investigations. It allows us to image directly, without further image processing, strongly scattering heavy-atom columns together with weakly scattering light-atom columns.
引用
收藏
页码:174 / 184
页数:11
相关论文
共 31 条
  • [1] PHASE RETRIEVAL THROUGH FOCUS VARIATION FOR ULTRA-RESOLUTION IN FIELD-EMISSION TRANSMISSION ELECTRON-MICROSCOPY
    COENE, W
    JANSSEN, G
    DEBEECK, MO
    VANDYCK, D
    [J]. PHYSICAL REVIEW LETTERS, 1992, 69 (26) : 3743 - 3746
  • [2] COENE W, 1992, SCANNING MICROSCOPY, V6, P379
  • [3] Towards 0.1 nm resolution with the first spherically corrected transmission electron microscope
    Haider, M
    Rose, H
    Uhlemann, S
    Kabius, B
    Urban, K
    [J]. JOURNAL OF ELECTRON MICROSCOPY, 1998, 47 (05): : 395 - 405
  • [4] A spherical-aberration-corrected 200 kV transmission electron microscope
    Haider, M
    Rose, H
    Uhlemann, S
    Schwan, E
    Kabius, B
    Urban, K
    [J]. ULTRAMICROSCOPY, 1998, 75 (01) : 53 - 60
  • [5] Electron microscopy image enhanced
    Haider, M
    Uhlemann, S
    Schwan, E
    Rose, H
    Kabius, B
    Urban, K
    [J]. NATURE, 1998, 392 (6678) : 768 - 769
  • [6] HEINEMANN K, 1971, OPTIK, V34, P113
  • [7] ULTRA-HIGH-RESOLUTION HVEM (H-1500) NEWLY CONSTRUCTED AT NIRIM .2. APPLICATION TO MATERIALS
    HORIUCHI, S
    MATSUI, Y
    KITAMI, Y
    YOKOYAMA, M
    SUEHARA, S
    WU, XJ
    MATSUI, I
    KATSUTA, T
    [J]. ULTRAMICROSCOPY, 1991, 39 (1-4) : 231 - 237
  • [8] LIMITS ON QUANTITATIVE INFORMATION FROM HIGH-RESOLUTION ELECTRON-MICROSCOPY OF YBA2CU3O7 SUPERCONDUCTORS
    HUXFORD, NP
    EAGLESHAM, DJ
    HUMPHREYS, CJ
    [J]. NATURE, 1987, 329 (6142) : 812 - 813
  • [9] Investigation of atomic displacements at a Σ3 {111} twin boundary in BaTiO3 by means of phase-retrieval electron microscopy
    Jia, CL
    Thust, A
    [J]. PHYSICAL REVIEW LETTERS, 1999, 82 (25) : 5052 - 5055
  • [10] Atomic-resolution imaging of oxygen in perovskite ceramics
    Jia, CL
    Lentzen, M
    Urban, K
    [J]. SCIENCE, 2003, 299 (5608) : 870 - 873