Coronal Alignment Correlates With Outcome After Total Knee Arthroplasty Five-Year Follow-Up of a Randomized Controlled Trial

被引:110
作者
Huang, Nathaniel F. R. [1 ,2 ]
Dowsey, Michelle M. [1 ,2 ]
Ee, Eric [1 ]
Stoney, James D. [1 ,2 ]
Babazadeh, Sina [2 ]
Choong, Peter F. [1 ,2 ]
机构
[1] St Vincents Hosp, Dept Orthopaed, Melbourne, Vic 3065, Australia
[2] Univ Melbourne, St Vincents Hosp Melbourne, Dept Surg, Melbourne, Vic 3010, Australia
关键词
computer-assisted surgery; knee arthroplasty; alignment; pain; function; patient quality of life; REPLACEMENT; NAVIGATION; QUALITY; SYSTEM; AXIS;
D O I
10.1016/j.arth.2012.03.058
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
In a prospective randomized control trial comparing computer-assisted vs conventional total knee arthroplasty, we previously reported that patients with coronal alignment within 3 degrees of neutral had superior international knee society and Short-Form 12 (SF-12) physical scores at 6 weeks, 3 months, 6 months, and 12 months after surgery. Computer-assisted total knee arthroplasty achieved greater accuracy in implant alignment, and this correlated with better knee function and quality of life. At 5 years, 90 of 111 patients assessed in our original study were reviewed. Coronal alignment within 3 degrees of neutral continued to be correlated with superior International Knee Society and SF-12 scores. Coronal alignment greater than 3 degrees was associated with a significant decline in SF-12 mental health scores.
引用
收藏
页码:1737 / 1741
页数:5
相关论文
共 20 条
[1]
The role of pain and function in determining patient satisfaction after total knee replacement - Data from the National Joint Registry for England and Wales [J].
Baker, P. N. ;
van der Meulen, J. H. ;
Lewsey, J. ;
Gregg, P. J. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (07) :893-900
[2]
Alignment in total knee arthroplasty -: A comparison of computer-assisted surgery with the conventional technique [J].
Bäthis, H ;
Perlick, L ;
Tingart, M ;
Lüring, C ;
Zurakowski, D ;
Grifka, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (05) :682-687
[3]
Navigated total knee replacement - A meta-analysis [J].
Bauwens, Kai ;
Matthes, Gerrit ;
Wich, Michael ;
Gebhard, Florian ;
Hanson, Beate ;
Ekkernkamp, Axel ;
Stengel, Dirk .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (02) :261-269
[4]
Choong PF, 2008, J ARTHROPLASTY
[5]
Leg axis after computer-navigated total knee arthroplasty - A prospective randomized trial comparing computer-navigated and manual implantation [J].
Decking, R ;
Markmann, Y ;
Fuchs, J ;
Puhl, W ;
Scharf, HP .
JOURNAL OF ARTHROPLASTY, 2005, 20 (03) :282-288
[6]
Ek E T H, 2008, J Orthop Surg (Hong Kong), V16, P192
[7]
The obesity epidemic - Its effect on total joint arthroplasty [J].
Fehring, Thomas K. ;
Odum, Susan M. ;
Griffin, William L. ;
Mason, J. Bohannon ;
Mccoy, Thomas H. .
JOURNAL OF ARTHROPLASTY, 2007, 22 (06) :71-76
[8]
Cross-validation of item selection and scoring for the SF-12 Health Survey in nine countries: Results from the IQOLA Project [J].
Gandek, B ;
Ware, JE ;
Aaronson, NK ;
Apolone, G ;
Bjorner, JB ;
Brazier, JE ;
Bullinger, M ;
Kaasa, S ;
Leplege, A ;
Prieto, L ;
Sullivan, M .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 1998, 51 (11) :1171-1178
[9]
Total knee arthroplasty implanted with and without kinematic navigation [J].
Hart, R ;
Janecek, M ;
Chaker, A ;
Bucek, P .
INTERNATIONAL ORTHOPAEDICS, 2003, 27 (06) :366-369
[10]
INSALL JN, 1989, CLIN ORTHOP RELAT R, P13