Results from the use of a preshaped lead for single-pass VDD/DDD stimulation

被引:7
作者
Israel, CW
Kruse, IM
Van Mechelen, R
Kroes, G
Heynen, H
Lokhoff, N
机构
[1] Ruhr Univ Bochum, St Josef Hosp, Dept Cardiol, Bochum, Germany
[2] Arvika Hosp, Dept Anaesthesiol, Arvika, Sweden
[3] St Franciscus Gasthuis, Dept Cardiol, Rotterdam, Netherlands
[4] Bakken Res Ctr, Maastricht, Netherlands
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1999年 / 22卷 / 09期
关键词
single-lead VDD stimulation; single-lead DDD stimulation; pacemaker leads; atrial sensing; atrial stimulation;
D O I
10.1111/j.1540-8159.1999.tb00624.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Main criticisms about single-pass VDD stimulation in patients with ASI block and normal sinus node function concern atrial undersensing in a lead with floating atrial electrodes, and loss of A V synchrony if sinus node dysfunction develops after implantation. We evaluated the concept of a preshaped single-pass lead designed to place the atrial ring electrodes in a constant position close to, or in contact with, the atrial wall. A preshaped lead (Model 2775, Medtronic Inc.) rr as implanted in 14 patients and followed for up to 2 years. Mean P wave amplitudes (PWAs) were 3.1 mV at implantation, 1.2 mV at predischarge, and 1.3 mV after 12 months. In all patients, minimal PWAs were well above maximal atrial sensitivity of the pacemaker in all body positions during the complete follow-up; atrial undersensing was not observed. Effective atrial stimulation was possible in all patients at implantation (mean stimulation threshold 2.5 V at 0.50 ms), in 11 patients on the first day after implant(mean stimulation threshold 0.22 ms at 5.0 V), in 10 patients after 1 month (mean stimulation threshold 0.57 ms at 5.0 Ir), and in 10 patients after 1 year (mean stimulation threshold 0.65 ms at 5.0 V). Intermittent phrenic nerve stimulation could be provoked in six patients. In conclusion, the concept of a preshaped single-pass lead facilitated implantation, improved atrial sensing performance, and allowed atrial stimulation in some patients. Still, further improvements are necessary to decrease the atrial stimulation thresholds to acceptable values in all pa tien ts.
引用
收藏
页码:1314 / 1320
页数:7
相关论文
共 21 条
[1]   ITALIAN MULTICENTER STUDY ON A SINGLE LEAD VDD PACING SYSTEM USING A NARROW ATRIAL DIPOLE SPACING [J].
ANTONIOLI, GE ;
ANSANI, L ;
BARBIERI, D ;
GUARDIGLI, G ;
PERCOCO, GF ;
TOSELLI, T .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (11) :1890-1893
[2]  
ANTONIOLI GE, 1997, PACE, V20, P1517
[3]   ATRIAL STIMULATION BY MEANS OF FLOATING ELECTRODES - A MULTICENTER EXPERIENCE [J].
BONGIORNI, MG ;
BEDENDI, N ;
BACCA, F ;
BINAGHI, G ;
BONGIORNI, MG ;
BOSSI, M ;
CALCATERRA, V ;
DIBIASE, M ;
FERRI, F ;
IACONO, M ;
ORLANDI, M ;
PASCOTTO, P ;
ROTIROTI, D ;
SANDRI, R ;
VERGASSOLA, R .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (11) :1977-1981
[4]   Toward optimizing a preshaped catheter and system parameters to achieve single lead DDD pacing [J].
Brownlee, RR ;
Swindle, MM ;
Bertolet, R ;
Neff, P .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (05) :1354-1358
[5]   EUROPEAN MULTICENTER PROSPECTIVE FOLLOW-UP-STUDY OF 1,002 IMPLANTS OF A SINGLE LEAD VDD PACING SYSTEM [J].
CRICK, JCP .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (11) :1742-1744
[6]   A MULTICENTER EVALUATION OF A SINGLE-PASS LEAD VDD PACING SYSTEM [J].
CURZIO, G .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (03) :434-442
[7]  
DelGiudice G, 1997, EUROPACE '97 - THE OFFICIAL MEETING OF THE WORKING GROUPS ON CARDIAC PACING AND ARRHYTHMIAS OF THE EUROPEAN SOCIETY OF CARDIOLOGY, P851
[8]  
DiGregorio F, 1997, EUROPACE '97 - THE OFFICIAL MEETING OF THE WORKING GROUPS ON CARDIAC PACING AND ARRHYTHMIAS OF THE EUROPEAN SOCIETY OF CARDIOLOGY, P857
[9]  
GASCON D, 1996, EUR JCPE S5, V6, P239
[10]   ACC/AHA Guidelines for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices: Executive summary - A report of the American College of Cardiology American Heart Association Task Force on Practice Guidelines (Committee on Pacemaker Implantation) [J].
Gregoratos, G ;
Cheitlin, MD ;
Conill, A ;
Epstein, AE ;
Fellows, C ;
Ferguson, TB ;
Freedman, RA ;
Hlatky, MA ;
Naccarelli, GV ;
Saksena, S ;
Schlant, RC ;
Silka, MJ .
CIRCULATION, 1998, 97 (13) :1325-1335