Tissue molecular ion imaging by gold cluster ion bombardment

被引:228
作者
Touboul, D
Halgand, F
Brunelle, A
Kersting, R
Tallarek, E
Hagenhoff, B
Laprévote, O
机构
[1] CNRS, Inst Chim Subst Nat, F-91198 Gif Sur Yvette, France
[2] Tascon GmbH, D-48149 Munster, Germany
关键词
D O I
10.1021/ac035243z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The use of gold cluster focused ion beams produced by a liquid metal ion gun in a TOF-SIMS mass spectrometer is shown to dramatically enhance secondary ion emission of phospholipids and peptides. The method has been successfully tested with cells grown onto plastic slips and with mouse brain slices, without any treatment of the samples. Very reliable time-of-flight mass spectra are acquired with a low primary ion dose of a few 107 ions, and high lateral resolution molecular ion images are obtained for heavy ions of great biological interest. This approach offers new opportunities in pharmacological and biological research fields by localizing compounds of interest such as drugs or metabolites in tissues.
引用
收藏
页码:1550 / 1559
页数:10
相关论文
共 51 条
[1]   NONLINEAR EFFECTS IN HEAVY-ION SPUTTERING [J].
ANDERSEN, HH ;
BAY, HL .
JOURNAL OF APPLIED PHYSICS, 1974, 45 (02) :953-954
[2]   Electrospray ionization and matrix assisted laser desorption/ionization mass spectrometry: Powerful analytical tools in recombinant protein chemistry [J].
Andersen, JS ;
Svensson, B ;
Roepstorff, P .
NATURE BIOTECHNOLOGY, 1996, 14 (04) :449-457
[3]  
[Anonymous], RAT BRAIN STEREOTAXI
[4]   COMPARISON OF POLYATOMIC AND ATOMIC PRIMARY BEAMS FOR SECONDARY ION MASS-SPECTROMETRY OF ORGANICS [J].
APPELHANS, AD ;
DELMORE, JE .
ANALYTICAL CHEMISTRY, 1989, 61 (10) :1087-1093
[5]   ORION PROJECT - ACCELERATION OF ION CLUSTERS AND HIGHLY CHARGED BIOMOLECULES FROM 10 MEV TO 1 GEV [J].
ATTAL, P ;
DELLANEGRA, S ;
GARDES, D ;
LARSON, JD ;
LEBEYEC, Y ;
VIENETLEGUE, R ;
WAAST, B .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 328 (1-2) :293-299
[6]   Time-of-flight secondary ion mass spectrometry: techniques and applications for the characterization of biomaterial surfaces [J].
Belu, AM ;
Graham, DJ ;
Castner, DG .
BIOMATERIALS, 2003, 24 (21) :3635-3653
[7]   IMPACT OF SLOW GOLD CLUSTERS ON VARIOUS SOLIDS - NONLINEAR EFFECTS IN SECONDARY ION EMISSION [J].
BENGUERBA, M ;
BRUNELLE, A ;
DELLANEGRA, S ;
DEPAUW, J ;
JORET, H ;
LEBEYEC, Y ;
BLAIN, MG ;
SCHWEIKERT, EA ;
BENASSAYAG, G ;
SUDRAUD, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1991, 62 (01) :8-22
[8]   TANDEM MASS SPECTROMETER FOR SECONDARY ION STUDIES [J].
BENNINGHOVEN, A ;
LOEBACH, E .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1971, 42 (01) :49-+
[9]   SECONDARY-ION YIELDS FROM SURFACES BOMBARDED WITH KEV MOLECULAR AND CLUSTER IONS [J].
BLAIN, MG ;
DELLANEGRA, S ;
JORET, H ;
LEBEYEC, Y ;
SCHWEIKERT, EA .
PHYSICAL REVIEW LETTERS, 1989, 63 (15) :1625-1628
[10]   ORGANIC FILM THICKNESS EFFECT IN SECONDARY ION MASS-SPECTROMETRY AND PLASMA DESORPTION MASS-SPECTROMETRY [J].
BOLBACH, G ;
VIARI, A ;
GALERA, R ;
BRUNOT, A ;
BLAIS, JC .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1992, 112 (01) :93-100