A quantitative evaluation of IMRT dose distributions: refinement and clinical assessment of the gamma evaluation

被引:238
作者
Depuydt, T [1 ]
Van Esch, A [1 ]
Huyskens, DP [1 ]
机构
[1] Univ Hosp Gasthuisberg, Div Radiat Phys, Dept Oncol, B-3000 Louvain, Belgium
关键词
gamma evaluation; intensity modulated radiotherapy; two-dimensional dose distributions;
D O I
10.1016/S0167-8140(01)00497-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Although intensity modulated radiotherapy (IMRT) is a step forward in comparison to conventional, static beam delivery, quality assurance is more complex and labour intensive, demanding detailed two-dimensional dosimetric verification. Regardless of the technique used for measuring the dose distribution, what is essential to the implementation of routine verification of IMRT fields is the efficient and accurate comparison of the measured versus desired dose distribution. In order to achieve a fast, yet accurate quantitative measure of the correspondence between measured and calculated close, the theoretical concept of the gamma evaluation method presented by Low et al. (Med. Phys., 25 (1998) 656) was converted into a calculation algorithm, taking into account practical considerations related to the discrete nature of the data. Materials and methods: A filter cascade of multiple levels was designed to obtain fast and accurate comparison of the two dose distributions under evaluation. The actual comparison consists of classification into accepted or rejected datapoint with respect to user-defined acceptance criteria (dose difference and distance to agreement). The presented algorithm was tested on dosimetric images calculated and/or acquired by means of a liquid filled portal imaging device during the course of intensity modulated treatments of prostate cancer, including pre-treatment verification as well as verification during treatment. To assess its ability to intercept possible errors in dose delivery, clinically relevant errors were deliberately introduced into the dose distributions. Results: The developed gamma filter method proves successful in the efficient comparison of calculated versus measured IMRT dose distribution. Secondly, intercomparison of dosimetric images acquired during different treatment sessions illustrate its potential to highlight variations in the dosimetric images. The simulated errors were unmistakably intercepted. Conclusions: The readily obtained gamma evaluation images are an easy tool for quality control of IMRT fields. To reduce the artefacts related to the discrete nature and limited resolution of the data, a fast and accurate filter cascade was developed, offering the possibility to use the gamma method for clay to day evaluation of patient dosimetric portal images with or without comparison to a predicted portal dose distribution. (C) 2002 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:309 / 319
页数:11
相关论文
共 11 条
[1]   Planning, delivery, and quality assurance of intensity-modulated radiotherapy using dynamic multileaf collimator: A strategy for large-scale implementation for the treatment of carcinoma of the prostate [J].
Burman, C ;
Chui, CS ;
Kutcher, G ;
Leibel, S ;
Zelefsky, M ;
LoSasso, T ;
Spirou, S ;
Wu, QW ;
Yang, J ;
Stein, J ;
Mohan, R ;
Fuks, Z ;
Ling, CC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (04) :863-873
[2]  
Harms William B., 1994, International Journal of Radiation Oncology Biology Physics, V30, P187
[3]   Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy [J].
LoSasso, T ;
Chui, CS ;
Ling, CC .
MEDICAL PHYSICS, 1998, 25 (10) :1919-1927
[4]   A technique for the quantitative evaluation of dose distributions [J].
Low, DA ;
Harms, WB ;
Mutic, S ;
Purdy, JA .
MEDICAL PHYSICS, 1998, 25 (05) :656-661
[5]   THE POTENTIAL AND LIMITATIONS OF THE INVERSE RADIOTHERAPY TECHNIQUE [J].
MOHAN, R ;
WANG, XH ;
JACKSON, A ;
BORTFELD, T ;
BOYER, AL ;
KUTCHER, GJ ;
LEIBEL, SA ;
FUKS, Z ;
LING, CC .
RADIOTHERAPY AND ONCOLOGY, 1994, 32 (03) :232-248
[6]   Portal dose image (PDI) prediction for dosimetric treatment verification in radiotherapy. I. An algorithm for open beams [J].
Pasma, KL ;
Heijmen, BJM ;
Kroonwijk, M ;
Visser, AG .
MEDICAL PHYSICS, 1998, 25 (06) :830-840
[7]   CALCULATION MODELS FOR DETERMINING THE ABSORBED DOSE IN WATER PHANTOMS IN OFF-AXIS PLANES OF RECTANGULAR FIELDS OF OPEN AND WEDGED PHOTON BEAMS [J].
STORCHI, P ;
WOUDSTRA, E .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (04) :511-527
[8]   Calculation of the absorbed dose distribution due to irregularly shaped photon beams using pencil beam kernels derived from basic beam data [J].
Storchi, P ;
Woudstra, E .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (04) :637-656
[9]   Pre-treatment dosimetric verification by means of a liquid-filled electronic portal imaging device during dynamic delivery of intensity modulated treatment fields [J].
Van Esch, A ;
Vanstraelen, B ;
Verstraete, J ;
Kutcher, G ;
Huyskens, D .
RADIOTHERAPY AND ONCOLOGY, 2001, 60 (02) :181-190
[10]  
VANDYK J, 1993, INT J RADIAT ONCOL, V26, P261, DOI 10.1016/0360-3016(93)90206-B