Pre-treatment dosimetric verification by means of a liquid-filled electronic portal imaging device during dynamic delivery of intensity modulated treatment fields

被引:60
作者
Van Esch, A [1 ]
Vanstraelen, B [1 ]
Verstraete, J [1 ]
Kutcher, G [1 ]
Huyskens, D [1 ]
机构
[1] Univ Hosp Gasthuisberg, Dept Oncol, Div Radiat Phys, B-3000 Louvain, Belgium
关键词
dynamic multileaf collimator; dosimetric verification; liquid-filled electronic portal imaging device;
D O I
10.1016/S0167-8140(01)00305-X
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Although intensity modulated radiation therapy is characterized by three-dimensional dose distributions which are often superior to those obtained with conventional treatment plans, its routine clinical implementation is partially held back by the complexity of the beam verification. This is even more so when a dynamic multileaf collimator (dMLC) is used instead of a segmented beam delivery. We have therefore investigated the possibility of using a commercially available, liquid-filled electronic portal imaging device (EPID) for the pre-treatment quality assurance of dynamically delivered dose distributions. Methods and materials: A special acquisition mode was developed to optimize the image acquisition speed for dosimetry with the liquid-filled EPID. We investigated the accuracy of this mode for 6 and 18 MV photon beams through comparison with film and ion chamber measurements. The impact of leaf speed and pulse rate fluctuations was quantified by means of dMLC plans especially designed for this purpose. Other factors influencing the accuracy of the dosimetry (e.g. the need for build-up, remanence of the ion concentration in the liquid and bulging of the liquid at non-zero gantry angles) were studied as well. We finally compared dosimetric EPID images with the corresponding image prediction delivered without a patient in the beam. Results: The dosimetric accuracy of the measured dose distribution is similar to2% with respect to film and ion chamber measurements. The accuracy declines when leaf speed is increased beyond 2 cm/s, but is fairly insensitive to accelerator pulse rate fluctuations. The memory effect is found to be of no clinical relevance. When comparing the acquired and expected distributions, an overall agreement of 3% can be obtained, except at areas of steep dose gradients where slight positional shifts are translated into large errors. Conclusions: Accurate dosimetric images of intensity modulated beam profiles delivered with a dMLC can be obtained with a commercially available, liquid-filled EPID. The developed acquisition mode is especially suited for fast and accurate pre-treatment verification of the intensity modulated fields. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:181 / 190
页数:10
相关论文
共 17 条
[1]   The dose response relationship of a liquid-filled electronic portal imaging device [J].
Boellaard, R ;
vanHerk, M ;
Mijnheer, BJ .
MEDICAL PHYSICS, 1996, 23 (09) :1601-1611
[2]   Planning, delivery, and quality assurance of intensity-modulated radiotherapy using dynamic multileaf collimator: A strategy for large-scale implementation for the treatment of carcinoma of the prostate [J].
Burman, C ;
Chui, CS ;
Kutcher, G ;
Leibel, S ;
Zelefsky, M ;
LoSasso, T ;
Spirou, S ;
Wu, QW ;
Yang, J ;
Stein, J ;
Mohan, R ;
Fuks, Z ;
Ling, CC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (04) :863-873
[3]   Relative profile and dose verification of intensity-modulated radiation therapy [J].
Chang, JW ;
Mageras, GS ;
Chui, CS ;
Ling, CC ;
Lutz, W .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 47 (01) :231-240
[4]   Verification of segmented beam delivery using a commercial electronic portal imaging device [J].
Curtin-Savard, AJ ;
Podgorsak, EB .
MEDICAL PHYSICS, 1999, 26 (05) :737-742
[5]   Dosimetric characteristics of a liquid-filled electronic portal imaging device [J].
Essers, M ;
Hoogervorst, BR ;
vanHerk, M ;
Lanson, H ;
Mijnheer, BJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1265-1272
[6]   Verification of dynamic multileaf collimation using an electronic portal imaging device [J].
James, HV ;
Atherton, S ;
Budgell, GJ ;
Kirby, MC ;
Williams, PC .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (02) :495-509
[7]   Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy [J].
LoSasso, T ;
Chui, CS ;
Ling, CC .
MEDICAL PHYSICS, 1998, 25 (10) :1919-1927
[8]   A technique for the quantitative evaluation of dose distributions [J].
Low, DA ;
Harms, WB ;
Mutic, S ;
Purdy, JA .
MEDICAL PHYSICS, 1998, 25 (05) :656-661
[9]   Quality assurance for dynamic multileaf collimator modulated fields using a fast beam imaging system [J].
Ma, LJ ;
Geis, PB ;
Boyer, AL .
MEDICAL PHYSICS, 1997, 24 (08) :1213-1220
[10]   THE POTENTIAL AND LIMITATIONS OF THE INVERSE RADIOTHERAPY TECHNIQUE [J].
MOHAN, R ;
WANG, XH ;
JACKSON, A ;
BORTFELD, T ;
BOYER, AL ;
KUTCHER, GJ ;
LEIBEL, SA ;
FUKS, Z ;
LING, CC .
RADIOTHERAPY AND ONCOLOGY, 1994, 32 (03) :232-248