Dosimetric characteristics of a liquid-filled electronic portal imaging device

被引:72
作者
Essers, M
Hoogervorst, BR
vanHerk, M
Lanson, H
Mijnheer, BJ
机构
[1] Department of Radiotherapy, The Netherlands Cancer Institute, 1066 CX Amsterdam, Antoni Leeuwenhoek Huis
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1995年 / 33卷 / 05期
关键词
radiotherapy; portal imaging; dosimetry; ionization chamber; quality assurance; in vivo dosimetry; transmission dosimetry;
D O I
10.1016/0360-3016(95)00108-5
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To determine the characteristics of a commercial electronic portal imaging device (EPID), based on a two-dimensional matrix of liquid-filled ionization chambers, for transmission dose measurements during patient treatment. Methods and Materials: Electronic portal imaging device measurements were performed in a cobalt-60 beam and two accelerator x-ray beams, and compared with measurements performed with a Farmer-type ionization chamber in air in a miniphantom and in an extended water phantom. Results: The warming up time of the EPID is about 1 h. The long-term stability of the detector is better than 1% under reference conditions for a period of about 3 months. The signal of the ionization chambers follows approximately the square root of the dose rate, although the relation becomes more linear for larger (> 1 Gy/min) dose rates. The signal can be transformed to dose rate with an accuracy of 0.6% (1 SD). The short-term influence of integrated dose on the sensitivity of the ionization chambers is small. The sensitivity increases about 0.5% for all ionization chambers after an absorbed dose of 8 Gy and returns to its original value in less than 5 min after stopping the irradiation. This small increase in sensitivity can be ascribed to the electrode distance of the ionization chambers in commercial EPIDs, which is 0.8 +/- 0.1 mm. The sensitivity increase depends on the electrode distance and is 4% for a 1.4 mm electrode distance. The scattering properties of the EPID ionization chambers were between those of an ionization chamber in a miniphantom and in a water phantom. Conclusion: The matrix ionization chamber EPID has characteristics that make it very suitable for dose rate measurements. It is therefore a very promising device for in vivo dosimetry purposes.
引用
收藏
页码:1265 / 1272
页数:8
相关论文
共 17 条
  • [1] BEDNAREK D R, 1976, Medical Physics (Woodbury), V3, P403, DOI 10.1118/1.594252
  • [2] MAXIMIZING SETUP ACCURACY USING PORTAL IMAGES AS APPLIED TO A CONFORMAL BOOST TECHNIQUE FOR PROSTATIC-CANCER
    BIJHOLD, J
    LEBESQUE, JV
    HART, AAM
    VIJLBRIEF, RE
    [J]. RADIOTHERAPY AND ONCOLOGY, 1992, 24 (04) : 261 - 271
  • [3] A REVIEW OF ELECTRONIC PORTAL IMAGING DEVICES (EPIDS)
    BOYER, AL
    ANTONUK, L
    FENSTER, A
    VANHERK, M
    MEERTENS, H
    MUNRO, P
    REINSTEIN, LE
    WONG, J
    [J]. MEDICAL PHYSICS, 1992, 19 (01) : 1 - 16
  • [4] A LIQUID IONIZATION-CHAMBER USING TETRAMETHYLSILANE
    ENGLER, J
    KEIM, H
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 223 (01) : 47 - 51
  • [5] DOSIMETRIC CONTROL OF CONFORMAL TREATMENT OF PAROTID-GLAND TUMORS
    ESSERS, M
    KEUS, R
    LANSON, JH
    MIJNHEER, BJ
    [J]. RADIOTHERAPY AND ONCOLOGY, 1994, 32 (02) : 154 - 162
  • [6] EXIT DOSE MEASUREMENTS BY PORTAL FILM DOSIMETRY
    FIORINO, C
    DELVECCHIO, A
    CATTANEO, GM
    FUSCA, M
    LONGOBARDI, B
    SIGNOROTTO, P
    CALANDRINO, R
    [J]. RADIOTHERAPY AND ONCOLOGY, 1993, 29 (03) : 336 - 340
  • [7] MEASUREMENT POSSIBILITIES USING AN ELECTRONIC PORTAL IMAGING DEVICE
    KIRBY, MC
    WILLIAMS, PC
    [J]. RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) : 237 - 243
  • [8] 1ST CLINICAL-EXPERIENCE WITH A NEWLY DEVELOPED ELECTRONIC PORTAL IMAGING DEVICE
    MEERTENS, H
    VANHERK, M
    BIJHOLD, J
    BARTELINK, H
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (05): : 1173 - 1181
  • [9] CONSISTENCY AND SIMPLICITY IN THE DETERMINATION OF ABSORBED DOSE TO WATER IN HIGH-ENERGY PHOTON BEAMS - A NEW CODE OF PRACTICE
    MIJNHEER, BJ
    AALBERS, AHL
    VISSER, AG
    WITTKAMPER, FW
    [J]. RADIOTHERAPY AND ONCOLOGY, 1986, 7 (04) : 371 - 384
  • [10] ARE PORT FILMS RELIABLE FOR INVIVO EXIT DOSE MEASUREMENTS
    VANDAM, J
    VAERMAN, C
    BLANCKAERT, N
    LEUNENS, G
    DUTREIX, A
    VANDERSCHUEREN, E
    [J]. RADIOTHERAPY AND ONCOLOGY, 1992, 25 (01) : 67 - 72