Application of amperometric sol-gel biosensor to flow injection determination of glucose

被引:27
作者
Couto, CMCM
Araújo, AN
Montenegro, MCBSM
Rohwedder, J
Raimundo, I
Pasquini, C
机构
[1] CEQUP, Dept Quim Fis, Fac Farm, P-4050 Oporto, Portugal
[2] Univ Estadual Campinas, Inst Quim, Campinas, SP, Brazil
[3] Inst Super Ciencias Saude, P-4580 Gandra, Paredes, Portugal
关键词
flow injection analysis; glucose oxidase; sol-gel; glucose biosensor;
D O I
10.1016/S0039-9140(01)00587-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A glucose biosensor with enzyme immobilised by sol-gel technology was constructed and evaluated. The glucose biosensor reported is based on encapsulated GOX within a sol-gel glass, prepared with 3-aminopropyltriethoxy silane, 2-(3,4-epoxycyclohexyl)-ethyltrimetoxy silane and HCl. A flow system incorporating the amperometric biosensor constructed was developed for the determination of glucose in the 1 x 10(-4)-5 x 10(-3) mol 1(-1) range with a precision of 1.5%. The results obtained for the analysis of electrolytic solution for iv administration and human serum samples showed good agreement between the proposed method and the reference procedure, with relative error < 5%. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:997 / 1003
页数:7
相关论文
共 24 条
  • [1] ELECTROCHEMICAL PROBING OF THE ACTIVITY OF GLUCOSE-OXIDASE EMBEDDED SOL-GEL MATRICES
    AUDEBERT, P
    DEMAILLE, C
    SANCHEZ, C
    [J]. CHEMISTRY OF MATERIALS, 1993, 5 (07) : 911 - 913
  • [2] THE SOL-GEL PREPARATION OF SILICA-GELS
    BUCKLEY, AM
    GREENBLATT, M
    [J]. JOURNAL OF CHEMICAL EDUCATION, 1994, 71 (07) : 599 - 602
  • [3] SOL-GEL VANADIUM PENTAOXIDE GLUCOSE BIOSENSOR
    GLEZER, V
    LEV, O
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1993, 115 (06) : 2533 - 2534
  • [4] IMMOBILIZED ENZYMES IN ANALYTICAL-CHEMISTRY
    GRAY, DN
    KEYES, MH
    WATSON, B
    [J]. ANALYTICAL CHEMISTRY, 1977, 49 (12) : 1067 - &
  • [5] Screen-printable surfactant-induced sol-gel graphite composites for electrochemical sensors
    Guo, YZ
    Guadalupe, AR
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1998, 46 (03) : 213 - 219
  • [6] KUNNZELMANN U, 1997, SENSOR ACTUAT B-CHEM, V38, P222
  • [7] LEV O, 1992, ANALUSIS, V20, P543
  • [8] Mediated amperometric glucose sensor modified by the sol-gel method
    Li, J
    Chia, LS
    Goh, NK
    Tan, SN
    Ge, H
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1997, 40 (2-3) : 135 - 141
  • [9] Optimization and characterization of a flow injection electrochemical system for pentachlorophenol assay
    Male, KB
    Saby, C
    Luong, JHT
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (19) : 4134 - 4139
  • [10] GLUCOSE BIOSENSOR BASED ON A SOL-GEL-DERIVED PLATFORM
    NARANG, U
    PRASAD, PN
    BRIGHT, FV
    RAMANATHAN, K
    KUMAR, ND
    MALHOTRA, BD
    KAMALASANAN, MN
    CHANDRA, S
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (19) : 3139 - 3144