Both combinatorial chemistry and parallel synthesis provide a valuable means for the production of large numbers of compounds with diverse molecular architectures that become available for various drug discovery experiments. In both the lead optimization and lead selection stages, one requirement that is common for many processes is the need for bioanalytical support. This review summarizes current high throughput strategies and efficient methodologies that are employed for drug metabolism and pharmacokinetic (DMPK) screens for a series of drug discovery compounds. For these types of assays, high performance liquid chromatography coupled to a tandem mass spectrometer (HPLC-MS/MS) has now become the technique of choice. The major high throughput strategies including sample reduction and cassette dosing are discussed. The methods for increasing the speed of HPLC-MS/MS-based analyses, such as fast chromatography, direct sample injection, parallel technologies and combined ionization interfaces are also presented in this review. In addition, the special challenges when performing HPLC-MS/MS bioanalysis, such as the choice of ionization sources, matrix ionization suppression and the potential for endogenous interferences, are addressed.
引用
收藏
页码:479 / 489
页数:11
相关论文
共 152 条
[1]  
Ackermann Bradley L., 2002, Current Topics in Medicinal Chemistry, V2, P53, DOI 10.2174/1568026023394605
[2]  
Allen MC, 1998, PHARMACEUT RES, V15, P93
[3]   Ion suppression in mass spectrometry [J].
Annesley, TM .
CLINICAL CHEMISTRY, 2003, 49 (07) :1041-1044
[4]  
Bayliss MK, 2000, RAPID COMMUN MASS SP, V14, P2039, DOI 10.1002/1097-0231(20001115)14:21<2039::AID-RCM130>3.0.CO
[5]  
2-2
[6]  
Beaudry F, 1998, RAPID COMMUN MASS SP, V12, P1216, DOI 10.1002/(SICI)1097-0231(19980915)12:17<1216::AID-RCM304>3.0.CO
[7]  
2-O
[8]   Collection, storage, and filtration of in vivo study samples using 96-well filter plates to facilitate automated sample preparation and LC/MS/MS analysis [J].
Berna, M ;
Murphy, AT ;
Wilken, B ;
Ackermann, B .
ANALYTICAL CHEMISTRY, 2002, 74 (05) :1197-+
[9]   Comparative study on the column performance of microparticulate 5-μm C18-bonded and monolithic C18-bonded reversed-phase columns in high-performance liquid chromatography [J].
Bidlingmaier, B ;
Unger, KK ;
von Doehren, N .
JOURNAL OF CHROMATOGRAPHY A, 1999, 832 (1-2) :11-16
[10]   Semi-automated liquid-liquid back-extraction in a 96-well format to decrease sample preparation time for the determination of dextromethorphan and dextrorphan in human plasma [J].
Bolden, RD ;
Hoke, SH ;
Eichhold, TH ;
McCauley-Myers, DL ;
Wehmeyer, KR .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 772 (01) :1-10