Determination of electron temperature, atomic fluorine concentration, and gas temperature in inductively coupled fluorocarbon/rare gas plasmas using optical emission spectroscopy

被引:62
作者
Schabel, MJ
Donnelly, VM
Kornblit, A
Tai, WW
机构
[1] Bell Labs, Lucent Technol, Murray Hill, NJ 07974 USA
[2] Agere Syst, Murray Hill, NJ 07974 USA
来源
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS | 2002年 / 20卷 / 02期
基金
英国医学研究理事会;
关键词
D O I
10.1116/1.1454126
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Recent advances in the interpretation of optical emission spectra from plasmas have made it possible to measure parameters such as electron temperature (T-g), relative electron density, and gas temperature (T-g) with this nonintrusive technique. Here we discuss the application of trace rare gas optical emission spectroscopy (TRG-OES), optical actinometry, and N-2 rotational spectroscopy to determine T-g relative electron density, fluorine atom concentration, and T-g for fluorocarbon/Ar plasmas in an inductively coupled reactor. Various etch processes, containing mixtures of a carrier gas, C2F6, and C4F8, were evaluated as a function of pressure and flowrate. Ar, Kr, and Ne were used individually or were mixed to comprise the carrier gas. In the case of TRG-OES and optical emission actinometry, a mixture containing equal parts of He, Ne, Ar, Kr, and Xe (similar to1% ea.) was added. A method for correcting excitation cross sections is introduced for cases when radiation trapping affects the emission of a rare gas (Ar) that is present at high concentrations. Experiments revealed that T-e can be controlled through the choice of carrier gas: Ne tends to increase T-e and Kr tends to decrease T-g relative to Ar. This phenomenon was verified qualitatively with a simple zero-dimensional energy balance model. Additional measurements revealed that the absolute atomic fluorine concentration, determined from calibrated F-to-Ar actinometry ratios, is roughly 20% of the total gas at 5 mTorr, and decreases to 5% at 60 mTorr. The gas temperature in the Ar-carrier plasma was measured to be similar to 1200 K and was found to be insensitive to pressure whereas T-g in Kr and Ne carrier gas plasmas increased from 1500-1900 K and 700-1500 K, respectively between 5 and 30 mTorr. (C) 2002 American Vacuum Society.
引用
收藏
页码:555 / 563
页数:9
相关论文
共 14 条
[1]   Measurement of electron-impact excitation into the 3p54p levels of argon using Fourier-transform spectroscopy [J].
Chilton, JE ;
Boffard, JB ;
Schappe, RS ;
Lin, CC .
PHYSICAL REVIEW A, 1998, 57 (01) :267-277
[2]   DEPENDENCE OF F-ATOM DENSITY ON PRESSURE AND FLOW-RATE IN CF4 GLOW-DISCHARGES AS DETERMINED BY EMISSION-SPECTROSCOPY [J].
COBURN, JW ;
CHEN, M .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY, 1981, 18 (02) :353-356
[3]  
DAVIS GP, 1983, J APPL PHYS, V54, P3080, DOI 10.1063/1.332514
[4]   ANISOTROPIC ETCHING OF SIO2 IN LOW-FREQUENCY CF4/O2 AND NF3/AR PLASMAS [J].
DONNELLY, VM ;
FLAMM, DL ;
DAUTREMONTSMITH, WC ;
WERDER, DJ .
JOURNAL OF APPLIED PHYSICS, 1984, 55 (01) :242-252
[5]  
DONNELLY VM, 1989, PLASMA DIAGNOSTICS D, V1, pCH1
[6]  
DONNELLY VM, IN PRESS J APPL PHYS
[7]  
Huber KP, 1979, MOL SPECTRA MOL STRU, DOI [10.1007/978-1-4757-0961-2_2, DOI 10.1007/978-1-4757-0961-2_2]
[8]   Comparison of the fluorine atom density measured by actinometry and vacuum ultraviolet absorption spectroscopy [J].
Kawai, Y ;
Sasaki, K ;
Kadota, K .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 1997, 36 (9AB) :L1261-L1264
[9]  
LIEBERMAN MA, 1994, PRINCIPLES PLASMA DI
[10]   Diagnostics of chlorine inductively coupled plasmas. Measurement of electron temperatures and electron energy distribution functions [J].
Malyshev, MV ;
Donnelly, VM .
JOURNAL OF APPLIED PHYSICS, 2000, 87 (04) :1642-1649