Magnetic resonance angiography of renal arterial stenosis

被引:18
作者
Grist, TM [1 ]
机构
[1] Univ Wisconsin, Dept Radiol, Madison, WI 53792 USA
[2] Univ Wisconsin, Dept Med Phys, Madison, WI 53792 USA
关键词
renal arteries; magnetic resonance; stenosis; diagnostic methods;
D O I
10.1097/00019501-199905000-00005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Recent developments in renal magnetic resonance angiography (MRA) have led to a significant improvement in the technical success rate and diagnostic accuracy of the methods. Specifically, three-dimensional contrast-enhanced MRA methods have been shown to provide a more reliable depiction of renal artery morphology than do older MRA techniques. In addition, preliminary work using adjunctive MRA techniques suggests that it is possible to determine the hemodynamic significance of renal artery disease using MRA and magnetic resonance imaging. MRA methods will therefore likely play an important role in the evaluation of patients with renovascular disease. Coronary Artery Dis 10:151-156 (C) 1999 Lippincott Williams & Wilkins.
引用
收藏
页码:151 / 156
页数:6
相关论文
共 46 条
[1]   IMAGING OF THE RENAL-ARTERIES - VALUE OF MR ANGIOGRAPHY [J].
DEBATIN, JF ;
SPRITZER, CE ;
GRIST, TM ;
BEAM, C ;
SVETKEY, LP ;
NEWMAN, GE ;
SOSTMAN, HD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (05) :981-990
[2]   Renal artery stenosis: Value of screening with three-dimensional phase-contrast MR angiography with a phased-array multicoil [J].
DeCobelli, F ;
Mellone, R ;
Salvioni, M ;
Vanzulli, A ;
Sironi, S ;
Manunta, P ;
Lanzani, C ;
Bianchi, G ;
DelMaschio, A .
RADIOLOGY, 1996, 201 (03) :697-703
[3]  
Duda SH, 1997, ACTA RADIOL, V38, P287
[4]   NONINVASIVE MEASUREMENT OF RENAL HEMODYNAMIC FUNCTIONS USING GADOLINIUM-ENHANCED MAGNETIC-RESONANCE-IMAGING [J].
DUMOULIN, CL ;
BUONOCORE, MH ;
OPSAHL, LR ;
KATZBERG, RW ;
DARROW, RD ;
MORRIS, TW ;
BATEY, C .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (03) :370-378
[5]   Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: Usefulness of a timing examination and MR power injector [J].
Earls, JP ;
Rofsky, NM ;
DeCorato, DR ;
Krinsky, GA ;
Weinreb, JC .
RADIOLOGY, 1996, 201 (03) :705-710
[6]   RENAL-ARTERIES - EVALUATION WITH OPTIMIZED 2D AND 3D TIME-OF-FLIGHT MR-ANGIOGRAPHY [J].
FELLNER, C ;
STROTZER, M ;
GEISSLER, A ;
KOHLER, SM ;
KRAMER, BK ;
SPIES, V ;
HELD, P ;
GMEINWIESER, J .
RADIOLOGY, 1995, 196 (03) :681-687
[7]   Automated detection of bolus arrival and initiation of data acquisition in fast, three-dimensional, gadolinium-enhanced MR angiography [J].
Foo, TKF ;
Saranathan, M ;
Prince, MR ;
Chenevert, TL .
RADIOLOGY, 1997, 203 (01) :275-280
[8]   MAGNETIC-RESONANCE ANGIOGRAPHY OF RENAL-ARTERY STENOSIS [J].
GEDROYC, WMW ;
NEERHUT, P ;
NEGUS, R ;
PALMER, A ;
ALKUTOUBI, A ;
TAUBE, D ;
HULME, B .
CLINICAL RADIOLOGY, 1995, 50 (07) :436-439
[9]   MAGNETIC-RESONANCE ANGIOGRAPHY OF RENAL-TRANSPLANTS [J].
GEDROYC, WMW ;
NEGUS, R ;
ALKUTOUBI, A ;
PALMER, A ;
TAUBE, D ;
HULME, B .
LANCET, 1992, 339 (8796) :789-791
[10]   MAGNETIC-RESONANCE ANGIOGRAPHY OF RENAL-ARTERY STENOSIS [J].
GRIST, TM .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1994, 24 (04) :700-712