A bioabsorbable everolimus-eluting coronary stent system (ABSORB): 2-year outcomes and results from multiple imaging methods

被引:613
作者
Serruys, Patrick W. [1 ]
Ormiston, John A. [3 ]
Onuma, Yoshinobu [1 ]
Regar, Evelyn [1 ]
Gonzalo, Nieves [1 ]
Garcia-Garcia, Hector M. [4 ]
Nieman, Koen [1 ,2 ]
Bruining, Nico [1 ]
Dorange, Cecile [5 ]
Miquel-Hebert, Karine [5 ]
Veldhof, Susan [5 ]
Webster, Mark [3 ]
Thuesen, Leif [6 ]
Dudek, Dariusz [7 ]
机构
[1] Erasmus MC, Ctr Thorax, Rotterdam, Netherlands
[2] Erasmus MC, Dept Radiol, Rotterdam, Netherlands
[3] Auckland City Hosp, Auckland, New Zealand
[4] Cardialysis BV, Rotterdam, Netherlands
[5] Abbott Vasc, Diegem, Belgium
[6] Aarhus Univ Hosp, Skejby Sygehus, Skejby, Denmark
[7] Jagiellonian Univ, Krakow, Poland
关键词
ATHEROSCLEROTIC PLAQUE COMPOSITION; INTRAVASCULAR ULTRASOUND; ARTERY LESIONS; ANGIOPLASTY; TOMOGRAPHY; COVERAGE;
D O I
10.1016/S0140-6736(09)60325-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Drug-eluting metallic coronary stents predispose to late stent thrombosis, prevent late lumen vessel enlargement, hinder surgical revascularisation, and impair imaging with multislice CT. We assessed the safety of the bioabsorbable everolimus-eluting stent (BVS). Methods 30 patients with a single de-novo coronary artery lesion were followed up for 2 years clinically and with multiple imaging methods: multislice CT, angiography, intravascular ultrasound, derived morphology parameters (virtual histology, palpography, and echogenicity), and optical coherence tomography (OCT). Findings Clinical data were obtained from 29 of 30 patients. At 2 years, the device was safe with no cardiac deaths, ischaemia-driven target lesion revascularisations, or stent thromboses recorded, and only one myocardial infarction (non-Q wave). 18-month multislice CT (assessed in 25 patients) showed a mean diameter stenosis of 19% (SD 9). At 2-year angiography, the in-stent late loss of 0.48 mm (SD 0.28) and the diameter stenosis of 27% (11) did not differ from the findings at 6 months. The luminal area enlargement on OCT and intravascular ultrasound between 6 months and 2 years was due to a decrease in plaque size without change in vessel size. At 2 years, 34.5% of strut locations presented no discernible features by OCT, confirming decreases in echogenicity and in radiofrequency backscattering; the remaining apparent struts were fully apposed. Additionally, vasomotion occurred at the stented site and adjacent coronary artery in response to vasoactive agents. Interpretation At 2 years after implantation the stent was bioabsorbed, had vasomotion restored and restenosis prevented, and was clinically safe, suggesting freedom from late thrombosis. Late luminal enlargement due to plaque reduction without vessel remodelling needs confirmation.
引用
收藏
页码:897 / 910
页数:14
相关论文
共 43 条
  • [41] Selective clearance of macrophages in atherosclerotic plaques by autophagy
    Verheye, Stefan
    Martinet, Wim
    Kockx, Mark M.
    Knaapen, Michiet W. M.
    Salu, Koen
    Timmermans, Jean-Pierre
    Ellis, Jeffrey T.
    Kilpatrick, Deborah L.
    De Meyer, Guido R. Y.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (06) : 706 - 715
  • [42] Quantification of the minimal luminal cross-sectional area after coronary stenting by two- and three-dimensional intravascular ultrasound versus edge detection and videodensitometry
    vonBirgelen, C
    Kutryk, MJB
    Gil, R
    Ozaki, Y
    DiMario, C
    Roelandt, JRTC
    deFeyter, PJ
    Serruys, PW
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1996, 78 (05) : 520 - 525
  • [43] EGG-gated three-dimensional intravascular ultrasound - Feasibility and reproducibility of the automated analysis of coronary lumen and atherosclerotic plaque dimensions in humans
    vonBirgelen, C
    deVrey, EA
    Mintz, GS
    Nicosia, A
    Bruining, N
    Li, WG
    Slager, CJ
    Roelandt, JRTC
    Serruys, PW
    deFeyter, PJ
    [J]. CIRCULATION, 1997, 96 (09) : 2944 - 2952