Heavy ion irradiation on silicon strip sensors for GLAST

被引:4
作者
Yoshida, S [2 ]
Yamanaka, K
Ohsugi, T
Masuda, H
Mizuno, T
Fukazawa, Y
Iwata, Y
Murakami, T
Sadrozinski, HFW
Yamamura, K
Yamamoto, K
Sato, K
机构
[1] Natl Inst Radiol Sci, Chiba 2638555, Japan
[2] Hiroshima Univ, Higashihiroshima 7398526, Japan
[3] Univ Calif Santa Cruz, Inst Particle Phys, Santa Cruz, CA 93106 USA
[4] Hamamatsu Photon KK, Hamamatsu, Shizuoka 4358558, Japan
关键词
crystal orientation; heavy ion; radiation damage; silicon strip detector (SSD); single event effects (SEE);
D O I
10.1109/TNS.2002.801481
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We investigated the damage of silicon strip sensors due to heavy-ion radiation as a check of the in-orbit stability of silicon strip sensors under cosmic-ray irradiation in the five-year gamma-ray large-area space telescope (GLAST) mission. In order to study single-event effects (SEE), we used Fe ions slowed-down in an absorber, with a resulting linear energy transfer (LET) of 8 MeV/(mg/cm(2)) on the surface of the sensor. The total doses achieved in two runs were about 8 krd and 22 krd, corresponding to a fluence of about 5 x 10(7) and 1.5 x 10(8) ions/cm(2), respectively. Silicon strip sensor with two different crystal orientations <111> and <100> were irradiated. We measured leakage currents and capacitances before and after irradiation to evaluate the damage. The leakage current density was found to increase by about 10 (nA/cm(2))/krd, as. expected for the ionizing irradiation. No significant changes of capacitances were found. In addition, no coupling capacitors were broken. The observed effects are well within the in-orbit requirements of the GLAST mission.
引用
收藏
页码:1756 / 1762
页数:7
相关论文
共 14 条
  • [1] The silicon tracker/converter for the gamma-ray large area space telescope
    Atwood, WB
    Hernando, JA
    Hirayama, M
    Johnson, RP
    Kröger, W
    Sadrozinski, HFW
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 435 (1-2) : 224 - 232
  • [2] Radiation damage experience at CDF with SVX'
    Azzi, P
    Bacchetta, N
    Bolla, G
    Glenzinski, D
    Haber, C
    Incandela, J
    Kajfasz, E
    Peters, MD
    Shaw, NM
    Snider, FP
    Spalding, J
    Spiegel, L
    Stuart, D
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 383 (01) : 155 - 158
  • [3] CAPACITANCES IN SILICON MICROSTRIP DETECTORS
    BARBERIS, E
    CARTIGLIA, N
    LEVIER, C
    RAHN, J
    RINALDI, P
    SADROZINSKI, HFW
    WICHMANN, R
    OHSUGI, T
    UNNO, Y
    MIYATA, H
    TAMURA, N
    YAMAMOTO, K
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 342 (01) : 90 - 95
  • [4] BLOOM ED, 1998, SLACR522
  • [5] Capacitance measurements of double-metal double-sided silicon microstrip detectors
    Bortoletto, D
    Garfinkel, AF
    Hardman, AD
    Hoffman, KD
    Keaffaber, TA
    Shaw, NM
    Stanley, GR
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 383 (01) : 104 - 109
  • [6] Voltages on silicon microstrip detectors in high radiation fields
    Dubbs, T
    Harms, M
    Sadrozinski, HFW
    Seiden, A
    Wilson, M
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (06) : 1902 - 1906
  • [7] *GSFC, 2001, GLAST00038 GSFC
  • [8] MICHELSON P, 1999, RESPONSE AO 99 OSS 0
  • [9] DOUBLE-SIDED MICROSTRIP SENSOR FOR THE BARREL OF THE SDC SILICON TRACKER
    OHSUGI, T
    IWATA, Y
    OHYAMA, H
    OHMOTO, T
    OKADA, M
    TAMURA, N
    HATAKENAKA, T
    UNNO, Y
    KOHRIKI, T
    HINODE, F
    UJIIE, N
    MIYATA, H
    MIYANO, K
    ASO, T
    DAIGO, M
    MURAKAMI, A
    KOBAYASHI, S
    TAKASHIMA, R
    HIGUCHI, M
    YAMAMOTO, K
    YAMAMURA, K
    MURAMATSU, M
    SEIDEN, A
    SADROZINSKI, H
    GRILLO, A
    CARTIGLIA, N
    BARBERIS, E
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 342 (01) : 16 - 21
  • [10] Design optimization of radiation-hard, double-sided, double-metal, AC-coupled silicon sensors
    Ohsugi, T
    Iwata, Y
    Ohmoto, T
    Handa, T
    Fujita, K
    Kitabayashi, H
    Sato, K
    Satoh, S
    Takashima, R
    Nakano, I
    Yamamoto, K
    Yamamura, K
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 436 (1-2) : 272 - 280