Radiation damage experience at CDF with SVX'

被引:24
作者
Azzi, P
Bacchetta, N
Bolla, G
Glenzinski, D
Haber, C
Incandela, J
Kajfasz, E
Peters, MD
Shaw, NM
Snider, FP
Spalding, J
Spiegel, L
Stuart, D
机构
[1] JOHNS HOPKINS UNIV,BALTIMORE,MD 21218
[2] UNIV CALIF BERKELEY,LAWRENCE BERKELEY LAB,BERKELEY,CA 94720
[3] FERMILAB NATL ACCELERATOR LAB,BATAVIA,IL 60510
[4] CTR PHYS PARTICULES MARSEILLE,MARSEILLE,FRANCE
[5] PURDUE UNIV,W LAFAYETTE,IN 47907
关键词
D O I
10.1016/S0168-9002(96)00621-3
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The radiation damage experience of the silicon vertex detector used in the CDF experiment during the 1993-1995 collider run is described. The detector is single sided, AC coupled, FOXFET biased, and uses radiation hard readout chips. The detector's noise is seen to increase anomalously with radiation dose.
引用
收藏
页码:155 / 158
页数:4
相关论文
共 10 条
[1]   THE CDF DETECTOR - AN OVERVIEW [J].
ABE, F ;
AMIDEI, D ;
APOLLINARI, G ;
ASCOLI, G ;
ATAC, M ;
AUCHINCLOSS, P ;
BADEN, AR ;
BARBAROGALTIERI, A ;
BARNES, VE ;
BARSOTTI, E ;
BEDESCHI, F ;
BELFORTE, S ;
BELLETTINI, G ;
BELLINGER, J ;
BENSINGER, J ;
BERETVAS, A ;
BERGE, P ;
BERTOLUCCI, S ;
BHADRA, S ;
BINKLEY, M ;
BLAIR, R ;
BLOCKER, C ;
BOFILL, J ;
BOOTH, AW ;
BRANDENBURG, G ;
BRENNER, A ;
BROWN, D ;
BYON, A ;
BYRUM, KL ;
CAMPBELL, M ;
CAREY, R ;
CARITHERS, W ;
CARLSMITH, D ;
CARROLL, JT ;
CASHMORE, R ;
CERVELLI, F ;
CHADWICK, K ;
CHAPIN, T ;
CHIARELLI, G ;
CHINOWSKY, W ;
CIHANGIR, S ;
CLINE, D ;
CONNOR, D ;
CONTRERAS, M ;
COOPER, J ;
CORDELLI, M ;
CURATOLO, M ;
DAY, C ;
DELFABBRO, R ;
DELLORSO, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 271 (03) :387-403
[2]   FOXFET BIASSED MICROSTRIP DETECTORS [J].
ALLPORT, PP ;
CARTER, JR ;
GIBSON, V ;
GOODRICK, MJ ;
HILL, JC ;
KATVARS, SG ;
BULLOUGH, MA ;
GREENWOOD, NM ;
LUCAS, AD ;
WILBURN, CD ;
CARTER, AA ;
PRITCHARD, TW ;
NARDINI, L ;
SELLER, P ;
THOMAS, SL .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 310 (1-2) :155-159
[3]   THE SILICON VERTEX DETECTOR OF THE COLLIDER DETECTOR AT FERMILAB [J].
AMIDEI, D ;
AZZI, P ;
BACCHETTA, N ;
BAILEY, MW ;
BARNETT, B ;
BEDESCHI, F ;
BISELLO, D ;
BOLOGNESI, V ;
BOSWELL, C ;
BUSETTO, G ;
CARITHERS, WC ;
CARTER, H ;
CASTRO, A ;
DELLAGNELLO, S ;
DERWENT, PF ;
DUCAR, R ;
DUNN, A ;
ELY, R ;
FLAUGHER, B ;
GALEOTTI, S ;
BARBAROGALTIERI, A ;
GARFINKEL, AF ;
HABER, C ;
HOLLAND, S ;
HRYCYK, M ;
HERRUP, D ;
HUGHES, R ;
KLEINFELDER, S ;
LORETI, M ;
MARIOTTI, M ;
MATTHEWS, J ;
MENZIONE, A ;
MERRICK, T ;
NELSON, C ;
PESCARA, L ;
PRODUIT, N ;
PUNZI, G ;
RAFFAELLI, F ;
RISTORI, L ;
SCHNEIDER, O ;
SEGLER, S ;
SHAPIRO, MD ;
SHAW, NM ;
SHAW, T ;
SKARHA, J ;
SNIDER, FD ;
SONG, TY ;
SPIES, A ;
TIPTON, P ;
TKACZYK, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 350 (1-2) :73-130
[4]  
AZZI P, 1995, CDF3278
[5]   FOXFET BIASED MICROSTRIP DETECTORS - AN INVESTIGATION OF RADIATION SENSITIVITY [J].
BACCHETTA, N ;
BISELLO, D ;
CANALI, C ;
DAROS, R ;
GIRALDO, A ;
GOTRA, Y ;
PACCAGNELLA, A ;
PIACENTINO, GM ;
VERZELLESI, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 342 (01) :39-48
[6]   DEGRADATION OF SILICON AC-COUPLED MICROSTRIP DETECTORS INDUCED BY RADIATION [J].
BACCHETTA, N ;
BISELLO, D ;
CANALI, C ;
FUOCHI, PG ;
GOTRA, Y ;
PACCAGNELLA, A ;
VERZELLESI, G .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (06) :2001-2007
[7]  
CIHANGIR S, FERMILAB94205E
[8]  
KAJFASZ E, 1994, P 3 INT WORKSH VERT
[9]  
LAAKO M, 1992, FERMILABTM1772
[10]   OPERATION AND RADIATION-RESISTANCE OF A FOXFET BIASING STRUCTURE FOR SILICON STRIP DETECTORS [J].
LAAKSO, M ;
SINGH, P ;
ENGELS, E ;
SHEPARD, PF .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 326 (1-2) :214-221