Solid contact potentiometric sensors for trace level measurements

被引:180
作者
Chumbimuni-Torres, KY
Rubinova, N
Radu, A
Kubota, LT
Bakker, E [1 ]
机构
[1] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
[2] Univ Estadual Campinas, Inst Chem, Dept Analyt Chem, BR-13083970 Campinas, SP, Brazil
关键词
D O I
10.1021/ac050749y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple procedure for the development of a range of polymeric ion-selective electrodes (ISEs) with low detection limits is presented. The electrodes were prepared by using a plasticizer-free methyl methacrylate-decyl methacrylate copolymer as membrane matrix and poly(3-octylthiophene) as intermediate layer deposited by solvent casting on gold sputtered copper electrodes as a solid inner contact. Five different electrodes were developed for Ag+, Pb2+, Ca2+, K+, and I-, with detection limits mostly in the nanomolar range. In, this work, the lowest detection limits reported thus far with solid contact ISEs for the detection of silver (2.0 x 10(-9) M), potassium (10(-7) M), and iodide (10(-8) M) are presented. The developed electrodes exhibited a good response time and excellent reproducibility.
引用
收藏
页码:1318 / 1322
页数:5
相关论文
共 49 条
  • [41] Large improvement of the lower detection limit of ion-selective polymer membrane electrodes
    Sokalski, T
    Ceresa, A
    Zwickl, T
    Pretsch, E
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1997, 119 (46) : 11347 - 11348
  • [42] A polypyrrole-based solid-contact Pb2+-selective PVC-membrane electrode with a nanomolar detection limit
    Sutter, J
    Lindner, E
    Gyurcsányi, RE
    Pretsch, E
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 380 (01) : 7 - 14
  • [43] Solid-contact polymeric membrane electrodes with detection limits in the subnanomolar range
    Sutter, J
    Radu, A
    Peper, S
    Bakker, E
    Pretsch, E
    [J]. ANALYTICA CHIMICA ACTA, 2004, 523 (01) : 53 - 59
  • [44] Potentiometric sensors for Ag+ based on poly(3-octylthiophene) (POT)
    Vázquez, M
    Bobacka, J
    Ivaska, A
    [J]. JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2005, 9 (12) : 865 - 873
  • [45] Monolithic capillary-based ion-selective electrodes
    Vigassy, T
    Huber, CG
    Wintringer, R
    Pretsch, E
    [J]. ANALYTICAL CHEMISTRY, 2005, 77 (13) : 3966 - 3970
  • [46] Nanomolar detection of amitriptyline by potentiometry with ion exchanger based PVC membrane ISEs
    Wang, CY
    Hu, XY
    Leng, ZZ
    Jin, GD
    [J]. ELECTROANALYSIS, 2003, 15 (08) : 709 - 714
  • [47] WYDLADACZ K, 2005, ANAL CHEM, V77, P4706
  • [48] All-solid-state planar miniature ion-selective chloride electrode
    Zielinska, R
    Mulik, E
    Michalska, A
    Achmatowicz, S
    Maj-Zurawska, M
    [J]. ANALYTICA CHIMICA ACTA, 2002, 451 (02) : 243 - 249
  • [49] A hexamethyl derivative of [9]mercuracarborand-3: Synthesis, characterization, and host-guest chemistry
    Zinn, AA
    Zheng, ZP
    Knobler, CB
    Hawthorne, MF
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1996, 118 (01) : 70 - 74