Renal artery stenosis: CT angiography - Comparison of real-time volume-rendering and maximum intensity projection algorithms

被引:85
作者
Johnson, PT
Halpern, EJ
Kuszyk, BS
Heath, DG
Wechsler, RJ
Nazarian, LN
Gardiner, GA
Levin, DC
Fishman, EK
机构
[1] Thomas Jefferson Univ Hosp, Dept Radiol, Philadelphia, PA 19107 USA
[2] Johns Hopkins Hosp, Russell H Morgan Dept Radiol, Baltimore, MD 21287 USA
关键词
computed tomography (CT); angiography; comparative studies; maximum intensity projection; volume rendering; renal arteries; CT; stenosis or obstruction;
D O I
10.1148/radiology.211.2.r99ap17337
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare results of helical computed tomographic (CT) angiography with real-time interactive volume rendering (VR) to CT angiography with maximum intensity projection (MIP) for the detection of renal artery stenosis. MATERIALS AND METHODS: Twenty-five patients underwent both conventional and CT angiography of the renal arteries. Images were blindly reviewed after rendering with MIP and Vp algorithms. MIP images were viewed in conjunction with axial CT images; VR models were evaluated in real time at the workstation without CT images. Findings in 50 main and 11 accessory renal arteries were categorized as normal or by degree of stenosis. RESULTS: All arteries depicted on conventional angiograms were visualized on MIP and VR images. Receiver operating characteristic (ROC) analysis for MIP and VIR images demonstrated excellent discrimination for the diagnosis of stenosis of at least 50% (area under the ROC curve, 0.96-0.99). Although sensitivity was not significantly different for VR and MIP (89% vs 94%, P > .1), specificity was greater with VR (99% vs 87%, P = .008 to .08). Stenosis of at least 50% was overestimated with CT angiography in four accessory renal arteries, but three accessory renal arteries not depicted at conventional angiography were depicted at CT angiography. CONCLUSION: In the evaluation of renal artery stenosis, Ct angiography with VR is faster and more accurate than CT angiography with MIP. Accessory arteries not depicted with conventional angiography were depicted with both CT angiographic algorithms.
引用
收藏
页码:337 / 343
页数:7
相关论文
共 15 条
[1]   Helical CT angiography compared with arteriography in the detection of renal artery stenosis [J].
Beregi, JP ;
Elkohen, M ;
Deklunder, G ;
Artaud, D ;
Coullet, JM ;
Wattinne, L .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (02) :495-501
[2]   TECHNICAL OPTIMIZATION OF SPIRAL CT FOR DEPICTION OF RENAL-ARTERY STENOSIS - IN-VITRO ANALYSIS [J].
BRINK, JA ;
LIM, JT ;
WANG, G ;
HEIKEN, JP ;
DEYOE, LA ;
VANNIER, MW .
RADIOLOGY, 1995, 194 (01) :157-163
[3]   A phantom study: Evaluation of renal artery stenosis using helical CT and 3D reconstructions [J].
Davros, WJ ;
Obuchowski, NA ;
Berman, PM ;
Zeman, RK .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (01) :156-161
[4]   RENAL ARTERIAL STENOSES - SPIRAL CT ANGIOGRAPHY [J].
GALANSKI, M ;
PROKOP, M ;
CHAVAN, A ;
SCHAEFER, CM ;
JANDELEIT, K ;
NISCHELSKY, JE .
RADIOLOGY, 1993, 189 (01) :185-192
[5]   THRESHOLD SELECTION FOR CT ANGIOGRAPHY SHADED SURFACE DISPLAY OF THE RENAL-ARTERIES [J].
HALPERN, EJ ;
WECHSLER, RJ ;
DICAMPLI, D .
JOURNAL OF DIGITAL IMAGING, 1995, 8 (03) :142-147
[6]   CT angiography with volume rendering: Advantages and applications in splanchnic vascular imaging [J].
Johnson, PT ;
Heath, DG ;
Kuszyk, BS ;
Fishman, EK .
RADIOLOGY, 1996, 200 (02) :564-568
[7]   Three-dimensional CT: Real-time interactive volume rendering [J].
Johnson, PT ;
Heath, DG ;
Bliss, DF ;
Cabral, B ;
Fishman, EK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (03) :581-583
[8]  
KANTEE R, 1997, RADIOLOGY, V205, P121
[9]  
KUSZYK BS, 1997, AJR, V168, P79