Amperometric biosensor for hypoxanthine based on immobilized xanthine oxidase on nanocrystal gold-carbon paste electrodes

被引:99
作者
Agüi, L [1 ]
Manso, J [1 ]
Yáñez-Sedeño, P [1 ]
Pingarrón, JM [1 ]
机构
[1] Univ Complutense Madrid, Fac Chem, Dept Analyt Chem, Madrid 28040, Spain
关键词
gold nanoparticle-modified electrodes; xanthine oxidase; hypoxanthine; electrochemical biosensors;
D O I
10.1016/j.snb.2005.03.001
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
The preparation and performance of a xanthine oxidase (XOD) biosensor, based on a carbon paste electrode (CPE) modified with electrodeposited gold nanoparticles (nAu), for the amperometric determination of hypoxanthine (Hx) is reported. Different XOD biosensor configurations were evaluated and compared with electrodes constructed by immobilizing XOD onto unmodified CPE and with biosensors prepared using glassy carbon electrodes and gold disk electrodes modified with electrodeposited gold. The XOD-nAu-CPE in which the enzyme was immobilized by cross-linking with glutaraldehyde (GA) and BSA exhibited the highest amperometric signal for Hx. Although Hx detection is usually carried out at potential values of around +600 mV versus Ag/AgCl, the GA-BSA-XOD-nAu-CPE allowed this detection to be carried out at 0.00 V, thus minimizing potential interferences from electrochemically oxidizable substances such as ascorbic acid. Experimental variables concerning the biosensor preparation were optimized. Calibration plots for Hx were constructed with the biosensor operating at +600 mV and at 0.00 V. The detection limit for Hx, 2.2 x 10(-7) mol l(-1) obtained using the latter potential value is similar to the best detection limits reported in the literature with other biosensor designs working at much more extreme potentials. The usefulness of the biosensor for the analysis of real samples was demonstrated by determining Hx in sardines and chicken meat. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:272 / 280
页数:9
相关论文
共 38 条
[1]
Colloidal-gold cysteamine-modified carbon paste electrodes as suitable electrode materials for the electrochemical determination of sulphur-containing compounds -: Application to the determination of methionine [J].
Agüí, L ;
Manso, J ;
Yáñez-Sedeño, P ;
Pingarrón, JM .
TALANTA, 2004, 64 (04) :1041-1047
[2]
Xanthine oxidase modified glassy carbon paste electrode [J].
Anik, U ;
Timur, S ;
Wang, J ;
Telefoncu, A .
ELECTROCHEMISTRY COMMUNICATIONS, 2004, 6 (09) :913-916
[3]
Xanthine and hypoxanthine sensors based on xanthine oxidase immobilized in poly(mercapto-p-benzoquinone) film [J].
Arai, G ;
Takahashi, S ;
Yasumori, I .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1996, 410 (02) :173-179
[4]
BARMAN TE, 1985, ENZYME HDB, V1, P112
[5]
Carralero V., 2005, ANAL CHIM ACTA, V528, P1
[6]
Amperometric detection of uric acid and hypoxanthine with Xanthine oxidase immobilized and carbon based screen-printed electrode. Application for fish freshness determination [J].
Carsol, MA ;
Volpe, G ;
Mascini, M .
TALANTA, 1997, 44 (11) :2151-2159
[7]
Cheng Q, 1998, ANAL CHIM ACTA, V369, P245, DOI 10.1016/S0003-2670(98)00213-X
[8]
COLLOIDAL GOLD AS A BIOCOMPATIBLE IMMOBILIZATION MATRIX SUITABLE FOR THE FABRICATION OF ENZYME ELECTRODES BY ELECTRODEPOSITION [J].
CRUMBLISS, AL ;
PERINE, SC ;
STONEHUERNER, J ;
TUBERGEN, KR ;
ZHAO, JG ;
HENKENS, RW .
BIOTECHNOLOGY AND BIOENGINEERING, 1992, 40 (04) :483-490
[9]
Characterization of electrochemically deposited gold nanocrystals on glassy carbon electrodes [J].
Finot, MO ;
Braybrook, GD ;
McDermott, MT .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 466 (02) :234-241
[10]
Development of an amperometric enzyme electrode biosensor for fish freshness detection [J].
Ghosh, S ;
Sarker, D ;
Misra, TN .
SENSORS AND ACTUATORS B-CHEMICAL, 1998, 53 (1-2) :58-62