Mid-short-term risk assessment of power systems considering impact of external environment

被引:27
作者
Zhang, Ning [1 ]
Kang, Chongqing [1 ]
Liu, Jingkun [1 ]
Xin, Jianbo [2 ]
Wan, Junbiao [2 ]
Hu, Jing [2 ]
Wei, Wenxiao [3 ]
机构
[1] Tsinghua Univ, Dept Elect Engn, State Key Lab Power Syst, Beijing 100084, Peoples R China
[2] Jiangxi Elect Power Res Inst, Nanchang 330096, Peoples R China
[3] Harbin Inst Technol, Sch Elect Engn & Automat, Harbin 150001, Peoples R China
关键词
Mid-short-term risk assessment; External environment; Natural disasters; Outage correlation; Conditional outage probability; METHODOLOGY;
D O I
10.1007/s40565-013-0026-y
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Ice flashover, lightning flashover and bird damage are the main reasons that cause transmission facility failure. The impact of these environmental factors on the operational risk levels of power systems should be taken into account in power system maintenance scheduling and operation planning. This paper studies the mid-short-term risk assessment methodology considering the impact of the external environment. The relationship model between natural disasters and transmission lines is presented. The conditional outage rate model and the sampling technique are then proposed considering the correlated outage of multiple transmission lines when a disaster happens. The framework of the mid-short-term risk assessment model is outlined. A test case of Jiangxi provincial power grid validates the proposed model. The results show that the model can quantify the impact of disasters on the forced outage rate of transmission component and their outage correlation, and thus effectively revealing the mid-short-term risk of power systems. The model can facilitate a more strategic decision-making on maintenance scheduling and operation planning of power systems.
引用
收藏
页码:118 / 126
页数:9
相关论文
共 27 条
  • [1] [Anonymous], 2009, GENERATING UNIT OPER
  • [2] [Anonymous], 2005, Risk Assessment Of Power Systems: Models, Methods, and Applications
  • [3] Application of adverse and extreme adverse weather: Modelling in transmission and distribution system reliability evaluation
    Billinton, R
    Singh, G
    [J]. IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2006, 153 (01) : 115 - 120
  • [4] Brostrom E., 2007, THESIS ROYAL I TECHN
  • [5] Cheng L, 2012, POWER SYST TECHNOL, V30, P8
  • [6] Annual risk assessment for overload security
    Dai, YJ
    McCalley, JD
    Abi-Samra, N
    Vittal, V
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2001, 16 (04) : 616 - 623
  • [7] Power system operation risk assessment using credibility theory
    Feng, Yongqing
    Wu, Wenchuan
    Zhang, Boming
    Li, Wenyuan
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2008, 23 (03) : 1309 - 1318
  • [8] He J., 2010, POWER SYSTEM PROTECT, V38, P31
  • [9] He Jian, 2009, Proceedings of the CSEE, V29, P39
  • [10] Hu B, 2005, P CSEE, V30, P29