Nonlinear interferometric vibrational imaging

被引:113
作者
Marks, DL
Boppart, SA
机构
[1] Univ Illinois, Dept Elect & Comp Engn, Beckman Inst Adv Sci & Technol, Urbana, IL 61801 USA
[2] Univ Illinois, Bioengn Program, Urbana, IL 61801 USA
[3] Univ Illinois, Coll Engn, Urbana, IL 61801 USA
[4] Univ Illinois, Coll Med, Urbana, IL 61801 USA
关键词
D O I
10.1103/PhysRevLett.92.123905
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Coherent anti-Stokes Raman scattering (CARS) processes are "coherent," but the phase of the anti-Stokes radiation is lost by most incoherent spectroscopic CARS measurements. We propose a Raman microscopy imaging method called nonlinear interferometric vibrational imaging, which measures Raman spectra by obtaining the temporal anti-Stokes signal through nonlinear interferometry. With a more complete knowledge of the anti-Stokes signal, we show through simulations that a high-resolution Raman spectrum can be obtained of a molecule in a single pulse using broad band radiation. This could be useful for identifying the three-dimensional spatial distribution of molecular species in tissue.
引用
收藏
页码:123905 / 1
页数:4
相关论文
共 21 条
[1]   In vivo cellular optical coherence tomography imaging [J].
Boppart, SA ;
Bouma, BE ;
Pitris, C ;
Southern, JF ;
Brezinski, ME ;
Fujimoto, JG .
NATURE MEDICINE, 1998, 4 (07) :861-865
[2]  
Bouma B.E., 2001, Handbook of Optical Coherence Tomography
[3]   Polarization coherent anti-Stokes Raman scattering microscopy [J].
Cheng, JX ;
Book, LD ;
Xie, XS .
OPTICS LETTERS, 2001, 26 (17) :1341-1343
[4]   In vivo ultrahigh-resolution optical coherence tomography [J].
Drexler, W ;
Morgner, U ;
Kärtner, FX ;
Pitris, C ;
Boppart, SA ;
Li, XD ;
Ippen, EP ;
Fujimoto, JG .
OPTICS LETTERS, 1999, 24 (17) :1221-1223
[5]   Single-pulse coherently controlled nonlinear Raman spectroscopy and microscopy [J].
Dudovich, N ;
Oron, D ;
Silberberg, Y .
NATURE, 2002, 418 (6897) :512-514
[6]   SCANNING COHERENT ANTI-STOKES RAMAN MICROSCOPE [J].
DUNCAN, MD ;
REINTJES, J ;
MANUCCIA, TJ .
OPTICS LETTERS, 1982, 7 (08) :350-352
[7]   Simplified setup for high-resolution spectroscopy that uses ultrashort pulses [J].
Gershgoren, E ;
Bartels, RA ;
Fourkas, JT ;
Tobey, R ;
Murnane, MM ;
Kapteyn, HC .
OPTICS LETTERS, 2003, 28 (05) :361-363
[8]  
Golub G. H., 1996, MATRIX COMPUTATIONS
[9]   MEASUREMENT OF NONRESONANT 3RD-ORDER SUSCEPTIBILITIES OF VARIOUS GASES BY THE NONLINEAR INTERFEROMETRIC-TECHNIQUE [J].
HAHN, JW ;
LEE, ES .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 1995, 12 (06) :1021-1027
[10]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181