Flash-lamp-pumped Ho:Tm:Cr:YAG and Ho:Tm:Er:YLF lasers: Modeling of a single, long pulse length comparison

被引:24
作者
Barnes, NP [1 ]
Murray, KE [1 ]
Jani, MG [1 ]
机构
[1] SCI & TECHNOL CORP,HAMPTON,VA 23665
来源
APPLIED OPTICS | 1997年 / 36卷 / 15期
关键词
D O I
10.1364/AO.36.003363
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Two methods of producing the long pulse lengths that promote efficient extraction of energy from low-gain, quasi-four-level lasers are analyzed. A long pulse length output can mitigate laser-induced damage effects and can be generated in quasi-four-level lasers by two disparate methods. One method utilizes Q-switching techniques in resonators designed to extend the pulse length and another utilizes the first pulse in a relaxation oscillation pulse train. Models for quasi-four-level lasers are derived here taking into account the nonnegligible thermal population of the lower laser level. Closed-form expressions are derived for both modes of operation of quasi-four-level laser systems so the parametric dependencies of both forms of operation become obvious, allowing facile comparison. In addition, a combined absorption and quantum efficiency, germane for flash-lamp pumping, is calculated for both Cr and Er sensitizers. Although the former has the advantage of broad absorption bands, the latter has the advantage of a quantum efficiency approaching 3. (C) 1997 Optical Society of America.
引用
收藏
页码:3363 / 3374
页数:12
相关论文
共 27 条
[11]  
Chesler R. B., 1970, Proceedings of the IEEE, V58, P1899, DOI 10.1109/PROC.1970.8062
[12]  
Chicklis E. P., 1974, ECOM730066F US ARM E
[13]   OPTICAL ABSORPTION CHARACTERISTICS OF PINK RUBY [J].
CRONEMEYER, DC .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1966, 56 (12) :1703-+
[14]   BLACKBODY ABSORPTION EFFICIENCIES FOR 6 LAMP PUMPED ND LASER MATERIALS [J].
CROSS, PL ;
BARNES, NP ;
SKOLAUT, MW ;
STORM, ME .
APPLIED OPTICS, 1990, 29 (06) :791-797
[15]  
DUNSMUIR R, 1963, J ELECTRON CONTR, V10, P453
[16]   SPECTROSCOPY AND DIODE LASER-PUMPED OPERATION OF TM, HO-YAG [J].
FAN, TY ;
HUBER, G ;
BYER, RL ;
MITZSCHERLICH, P .
IEEE JOURNAL OF QUANTUM ELECTRONICS, 1988, 24 (06) :924-933
[17]   Flash-lamp-pumped Ho:Tm:Cr:YAG and Ho:Tm:Er:YLF lasers: Experimental results of a single, long pulse length comparison [J].
Jani, MG ;
Barnes, NP ;
Murray, KE .
APPLIED OPTICS, 1997, 36 (15) :3357-3362
[18]  
KINTZ GJ, 1987, OSA 1987, V14
[19]  
KOECHNER W, 1976, SOLID STATE LASER EN, P245
[20]  
ROGENOV MA, 1990, OPT QUANTUM ELECT, V22, P561