A meta-analysis of three decades of validating thoracic impedance cardiography

被引:107
作者
Raaijmakers, E
Faes, TJC
Scholten, RJPM
Goovaerts, HG
Heethaar, RM
机构
[1] Univ Hosp Amsterdam, Inst Cardiovasc Res, Dept Med Phys & Informat, Amsterdam, Netherlands
[2] Univ Hosp Amsterdam, Inst Res Extramural Med, Amsterdam, Netherlands
关键词
meta-analysis; thoracic impedance cardiography; cardiac output; stroke volume; validity; subject characteristics; methodology; reference method; correlation coefficient;
D O I
10.1097/00003246-199906000-00053
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To provide a meta-analysis of current literature concerning the validation of thoracic impedance cardiography (TIC) and to explain the variations in the reported results from the differences in the studies. Data Sources: A computer-assisted search of English-language, German, and Dutch literature was performed for the period January 1966 to April 1997. Moreover, references from review articles were obtained. Study Selection: A total of 154 studies comparing measurements of cardiac output or related variables obtained from TIC and a reference method were analyzed. Data Extraction: Articles were classified by differences in Tie methodology, reference method, and subject characteristics. Fisher's Z(f) transformed correlation coefficients were used to compare results. Data were pooled using the random-effects method. Data Synthesis: An overall pooled r(2) value of .67 (95% confidence interval, 0.64-0.71) was found. However, the correlation was higher in repeated-measurement designs than in single-measurement designs (r(2) = .53; 95% confidence interval, 0.43-0.62). Further research using analysis of variance revealed a significant influence of the reference method and the subject characteristics on the correlation coefficient. The correlation was significantly better in animals than in cardiac patients. Subgroup analysis revealed that TIC correlated significantly better to the indirect Fick method than to echocardiography in healthy subjects. No significant influence of the applied TIC methodology was found. Discussion: The overall r(2) value of .67 indicates that TIC might be useful for trend analysis of different groups of patients. However, for diagnostic interpretation, a r(2) value of .53 might not meet the required accuracy of the study. Great care should be taken when TIC is applied to the cardiac patient. However, because the applied reference method was of significant influence, differences between TIC and the reference method are incorrectly attributed to errors in TIC alone.
引用
收藏
页码:1203 / 1213
页数:11
相关论文
共 177 条
[1]  
ADAMICZA A, 1994, ACTA PHYSL HUNGARIA, V81, P37
[2]  
ALLEN MJ, 1979, INTRO MEASUREMENT TH, P46
[3]   IMPEDANCE CARDIOGRAPHY FOR REPEATED DETERMINATION OF STROKE VOLUME IN ELDERLY HYPERTENSIVES - CORRELATION WITH PULSED DOPPLER ECHOCARDIOGRAPHY [J].
ANTONICELLI, R ;
SAVONITTO, S ;
GAMBINI, C ;
TOMASSINI, PF ;
SARDINA, M ;
PACIARONI, E .
ANGIOLOGY, 1991, 42 (08) :648-653
[4]   EVALUATION OF A CONTINUOUS, ONLINE REAL-TIME NONINVASIVE CARDIAC-OUTPUT AND EJECTION FRACTION MEASUREMENTS BY ELECTRICAL BIOIMPEDANCE IN CRITICALLY ILL PATIENTS [J].
APPEL, PL ;
BERNSTEIN, DP ;
CURTIS, DL ;
SHOEMAKER, WC ;
KRAM, HB ;
FLEMING, AW .
CRITICAL CARE MEDICINE, 1987, 15 (04) :364-364
[5]   COMPARISON OF MEASUREMENTS OF CARDIAC-OUTPUT BY BIOIMPEDANCE AND THERMODILUTION IN SEVERELY ILL SURGICAL PATIENTS [J].
APPEL, PL ;
KRAM, HB ;
MACKABEE, J ;
FLEMING, AW ;
SHOEMAKER, WC .
CRITICAL CARE MEDICINE, 1986, 14 (11) :933-935
[6]   COMPARISON OF IMPEDANCE CARDIOGRAPHY AND ECHOCARDIOGRAPHY FOR MEASUREMENT OF STROKE VOLUME [J].
AUST, PE ;
BELZ, GG ;
BELZ, G ;
KOCH, W .
EUROPEAN JOURNAL OF CLINICAL PHARMACOLOGY, 1982, 23 (06) :475-477
[7]  
BACHE RJ, 1969, AM J MED SCI, V258, P100
[8]  
BAKER L E, 1971, Cardiovascular Research Center Bulletin (Houston), V9, P135
[9]   ESOPHAGEAL ELECTRODES ALLOW PRECISE ASSESSMENT OF CARDIAC-OUTPUT BY BIOIMPEDANCE [J].
BALESTRA, B ;
MALACRIDA, R ;
LEONARDI, L ;
SUTER, P ;
MARONE, C .
CRITICAL CARE MEDICINE, 1992, 20 (01) :62-67
[10]   Comparison of impedance cardiography with thermodilution and direct fick methods for noninvasive measurement of stroke volume and cardiac output during incremental exercise in patients with ischemic cardiomyopathy [J].
Belardinelli, R ;
Ciampani, N ;
Costantini, C ;
Blandini, A ;
Purcaro, A .
AMERICAN JOURNAL OF CARDIOLOGY, 1996, 77 (15) :1293-1301