A meta-analysis of three decades of validating thoracic impedance cardiography

被引:107
作者
Raaijmakers, E
Faes, TJC
Scholten, RJPM
Goovaerts, HG
Heethaar, RM
机构
[1] Univ Hosp Amsterdam, Inst Cardiovasc Res, Dept Med Phys & Informat, Amsterdam, Netherlands
[2] Univ Hosp Amsterdam, Inst Res Extramural Med, Amsterdam, Netherlands
关键词
meta-analysis; thoracic impedance cardiography; cardiac output; stroke volume; validity; subject characteristics; methodology; reference method; correlation coefficient;
D O I
10.1097/00003246-199906000-00053
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To provide a meta-analysis of current literature concerning the validation of thoracic impedance cardiography (TIC) and to explain the variations in the reported results from the differences in the studies. Data Sources: A computer-assisted search of English-language, German, and Dutch literature was performed for the period January 1966 to April 1997. Moreover, references from review articles were obtained. Study Selection: A total of 154 studies comparing measurements of cardiac output or related variables obtained from TIC and a reference method were analyzed. Data Extraction: Articles were classified by differences in Tie methodology, reference method, and subject characteristics. Fisher's Z(f) transformed correlation coefficients were used to compare results. Data were pooled using the random-effects method. Data Synthesis: An overall pooled r(2) value of .67 (95% confidence interval, 0.64-0.71) was found. However, the correlation was higher in repeated-measurement designs than in single-measurement designs (r(2) = .53; 95% confidence interval, 0.43-0.62). Further research using analysis of variance revealed a significant influence of the reference method and the subject characteristics on the correlation coefficient. The correlation was significantly better in animals than in cardiac patients. Subgroup analysis revealed that TIC correlated significantly better to the indirect Fick method than to echocardiography in healthy subjects. No significant influence of the applied TIC methodology was found. Discussion: The overall r(2) value of .67 indicates that TIC might be useful for trend analysis of different groups of patients. However, for diagnostic interpretation, a r(2) value of .53 might not meet the required accuracy of the study. Great care should be taken when TIC is applied to the cardiac patient. However, because the applied reference method was of significant influence, differences between TIC and the reference method are incorrectly attributed to errors in TIC alone.
引用
收藏
页码:1203 / 1213
页数:11
相关论文
共 177 条
[61]   IMPORTANCE OF BLOOD RESISTIVITY IN MEASUREMENT OF CARDIAC-OUTPUT BY THORACIC IMPEDANCE METHOD [J].
HILL, DW ;
THOMPSON, FD .
MEDICAL & BIOLOGICAL ENGINEERING, 1975, 13 (02) :187-190
[62]   EFFECT OF HEMATOCRIT ON RESISTIVITY OF HUMAN-BLOOD AT 37DEGREESC AND 100 KHZ [J].
HILL, DW ;
THOMPSON, FD .
MEDICAL & BIOLOGICAL ENGINEERING, 1975, 13 (02) :182-186
[63]  
Hiltmann W D, 1974, Verh Dtsch Ges Inn Med, V80, P1181
[64]  
HORSTMANN E, 1993, MED PROG TECHNOL, V19, P173
[65]   STROKE VOLUME MEASUREMENTS BY ELECTRICAL BIOIMPEDANCE AND ECHOCARDIOGRAPHY IN HEALTHY-VOLUNTEERS [J].
HUANG, KC ;
STODDARD, M ;
TSUEDA, K ;
HEINE, MF ;
THOMAS, MH ;
WHITE, M ;
WIEMAN, TJ .
CRITICAL CARE MEDICINE, 1990, 18 (11) :1274-1278
[66]   USE OF TRANS-THORACIC BIOIMPEDANCE TO DETERMINE CARDIAC-OUTPUT IN PEDIATRIC-PATIENTS [J].
INTRONA, RPS ;
PRUETT, JK ;
CRUMRINE, RC ;
CUADRADO, AR .
CRITICAL CARE MEDICINE, 1988, 16 (11) :1101-1105
[67]   THE THERMODILUTION METHOD FOR THE CLINICAL-ASSESSMENT OF CARDIAC-OUTPUT [J].
JANSEN, JRC .
INTENSIVE CARE MEDICINE, 1995, 21 (08) :691-697
[68]  
JAVEED M, 1990, Critical Care Medicine, V18, pS248, DOI 10.1097/00003246-199012001-00138
[69]   A REVIEW OF IMPEDANCE CARDIOGRAPHY [J].
JENSEN, L ;
YAKIMETS, J ;
TEO, KK .
HEART & LUNG, 1995, 24 (03) :183-193
[70]   NONINVASIVE MEASUREMENT OF CARDIAC-OUTPUT BY THORACIC ELECTRICAL BIOIMPEDANCE - A STUDY OF REPRODUCIBILITY AND COMPARISON WITH THERMODILUTION [J].
JEWKES, C ;
SEAR, JW ;
VERHOEFF, F ;
SANDERS, DJ ;
FOEX, P .
BRITISH JOURNAL OF ANAESTHESIA, 1991, 67 (06) :788-794