Maximal expansion capacity with current DES platforms: a critical factor for stent selection in the treatment of left main bifurcations?

被引:69
作者
Foin, Nicolas [1 ]
Sen, Sayan [1 ]
Allegria, Eduardo [2 ]
Petraco, Ricardo [1 ]
Nijjer, Sukh [1 ]
Francis, Darrel P. [1 ]
Di Mario, Carlo [2 ]
Davies, Justin E. [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Int Ctr Circulatory Hlth, London W2 1LA, England
[2] Royal Brompton & Harefield NHS Trust, Biomed Res Unit, London, England
关键词
bifurcation; DES; left main; stent; workhorses; DRUG-ELUTING STENTS; PERCUTANEOUS CORONARY INTERVENTION; IN-VIVO ASSESSMENT; SIDE-BRANCH; INTRAVASCULAR ULTRASOUND; KISSING BALLOON; ARTERY-DISEASE; RECOIL; IMPLANTATION; DEFORMATION;
D O I
10.4244/EIJV8I11A200
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
Aims: Left main stenting is increasingly performed and often involves deployment of a single stent across vessels with marked disparity in diameters. Knowing stent expansion capacity is critical to ensure adequate strut apposition after post-dilatation of the stent has been performed. Coronary stents are usually manufactured in only two or three different model designs with each design having a different maximal expansion capacity. Information about the different workhorse designs and their maximal achievable diameter is not commonly provided by manufacturers but, in the absence of this critically important information, stents implanted in segments with major changes in vessel diameter have the potential to become grossly overstretched and to remain incompletely apposed. Methods and results: We examined the differences in workhorse designs of six commercially available drug-eluting stents (DES): the PROMUS Element, TAXUS Liberte, XIENCE PRIME, Resolute Integrity, BioMatrix Flex and CYPHER SELECT stents. Using micro-computed tomography, we tested oversizing capabilities above nominal pressures for the different workhorse designs of the six DES using 4.0, 5.0 and 6.0 mm post-dilatation balloons inflated to 14 atmospheres. MLD could be increased significantly in all stents, only restricted by workhorse design limitations. Minimal inner lumen diameter (MLD) achieved after two successive 6.0 mm post-dilatations of the largest design (4.0 mm stent) was 5.7 mm for the Element, 5.6 mm for the XIENCE PRIME, 6.0 mm for the TAXUS, 5.4 mm for the Resolute Integrity, 5.9 mm for the BioMatrix and 5.8 mm for the Cypher stent. Significant deformations were observed during stent oversizing with large changes in terms of cell opening and crowns expansion. These are affected by design structure and reveal important differences among all stents tested. Such extensive deformations may alter the functional ability of an individual stent to scaffold a lesion and prevent restenosis. Conclusions: Stent selection based on stent model design may be critical, particularly for treatment of large artery and left main bifurcations where overexpansion is normally required to optimise results and ensure full expansion of the stent.
引用
收藏
页码:1315 / 1325
页数:11
相关论文
共 29 条
[1]
[Anonymous], 2010, GUID IND FDA STAFF N
[2]
[Anonymous], 2010, EV XIENCE PRIME EV E
[3]
Stent expansion: a combination of delivery balloon underexpansion and acute stent recoil reduces predicted stent diameter irrespective of reference vessel size [J].
Aziz, Shahid ;
Morris, John L. ;
Perry, Raphael A. ;
Stables, Rodney H. .
HEART, 2007, 93 (12) :1562-1566
[4]
Scanning electron microscopic assessment of coating irregularities and their precursors in unexpanded durable polymer-based drug-eluting stents [J].
Basalus, Mounir W. Z. ;
Tandjung, Kenneth ;
van Westen, Thea ;
Sen, Hanim ;
van der Jagt, Pasquelle K. N. ;
Grijpma, Dirk W. ;
van Apeldoorn, Aart A. ;
von Birgelen, Clemens .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2012, 79 (04) :644-653
[5]
Basalus MWZ, 2010, EUROINTERVENTION, V6, P141, DOI 10.4244/
[6]
Mechanisms of residual lumen stenosis after high-pressure stent implantation -: A quantitative coronary angiography and intravascular ultrasound study [J].
Bermejo, J ;
Botas, J ;
García, E ;
Elízaga, J ;
Osende, J ;
Soriano, J ;
Abeytua, M ;
Delcán, JL .
CIRCULATION, 1998, 98 (02) :112-118
[7]
Experimental and computational flow evaluation of coronary stents [J].
Berry, JL ;
Santamarina, A ;
Moore, JE ;
Roychowdhury, S ;
Routh, WD .
ANNALS OF BIOMEDICAL ENGINEERING, 2000, 28 (04) :386-398
[8]
In vivo assessment of stent expansion and recoil in normal porcine coronary arteries - Differential outcome by stent design [J].
Carrozza, JP ;
Hosley, SE ;
Cohen, DJ ;
Baim, DS .
CIRCULATION, 1999, 100 (07) :756-760
[9]
Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation [J].
Cook, Stephane ;
Wenaweser, Peter ;
Togni, Mario ;
Billinger, Michael ;
Morger, Cyrill ;
Seiler, Christian ;
Vogel, Rolf ;
Hess, Otto ;
Meier, Bernhard ;
Windecker, Stephan .
CIRCULATION, 2007, 115 (18) :2426-2434
[10]
Escaned J, 2011, EUROINTERVENTION SM, V7