Optical fiber coupled light emitting diode based absorbance detector with a reflective flow cell

被引:40
作者
Jambunathan, S
Dasgupta, PK [1 ]
Wolcott, DK
Marshall, GD
Olson, DC
机构
[1] Texas Tech Univ, Dept Chem & Biochem, Lubbock, TX 79409 USA
[2] Global FIA Inc, Gig Harbor, WA 98335 USA
关键词
optical absorbance detectors; optical fiber coupled light emitting diode; reflective flow-through cell;
D O I
10.1016/S0039-9140(99)00132-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We present a versatile, optical fiber coupled light emitting diode (LED) light source based flow-through optical absorbance detector. The LED source is readily changeable. Optical fibers are used to carry light from the electronics/display unit to a reflective flow-through cell and back. The cell can thus be located remotely from the electronics unit and the umbilical connection is not susceptible to electrical noise. The noise level of this detector with LEDs of different emission maxima were observed to be in the range of 3-20 mu AU under actual use conditions, with a maximum short term drift of 4 mu AU/min after the initial warm-up period. When the analyte absorbance is well matched with the source emission characteristics, the detector response is linear with concentration over at least two orders of magnitude. The liquid flow path through the cell is linear with a large exit aperture such that bubbles are not trapped in the optical path. The optical arrangement is such that the incident light crosses the liquid flow orthogonally and is reflected back by a rear mirror to the receiver fiber. This arrangement reduces the refractive index sensitivity by an order of magnitude relative to conventional Z-path flow cells. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:481 / 490
页数:10
相关论文
共 20 条
[1]  
BETTERIDGE D, 1978, ANALYST, V103, P897, DOI 10.1039/an9780300897
[2]   An affordable high-performance optical absorbance detector for capillary systems [J].
Boring, CB ;
Dasgupta, PK .
ANALYTICA CHIMICA ACTA, 1997, 342 (2-3) :123-132
[3]   Simultaneous multiple injection in monosegmented flow analysis [J].
Brito, VO ;
Raimundo, IM .
ANALYTICA CHIMICA ACTA, 1998, 371 (2-3) :317-+
[4]   THE PIGTAILING APPROACH TO OPTICAL-DETECTION IN CAPILLARY ELECTROPHORESIS [J].
BRUNO, AE ;
MAYSTRE, F ;
KRATTIGER, B ;
NUSSBAUM, P ;
GASSMANN, E .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1994, 13 (05) :190-198
[5]   Capillary electrophoresis detector using a light emitting diode and optical fibres [J].
Butler, PAG ;
Mills, B ;
Hauser, PC .
ANALYST, 1997, 122 (09) :949-953
[6]   Luminescence detection with a liquid care waveguide [J].
Dasgupta, PK ;
Zhang, GF ;
Li, JZ ;
Boring, CB ;
Jambunathan, S ;
Al-Horr, R .
ANALYTICAL CHEMISTRY, 1999, 71 (07) :1400-1407
[7]   SANDWICH-TYPE FLOW-THROUGH FIBEROPTIC CELLS FOR OPTICAL ABSORBENCY MEASUREMENTS [J].
DASGUPTA, PK ;
BELLAMY, HS ;
LIU, HH .
TALANTA, 1993, 40 (03) :341-345
[8]   LIGHT-EMITTING DIODE BASED FLOW-THROUGH OPTICAL-ABSORPTION DETECTORS [J].
DASGUPTA, PK ;
BELLAMY, HS ;
LIU, HH ;
LOPEZ, JL ;
LOREE, EL ;
MORRIS, K ;
PETERSEN, K ;
MIR, KA .
TALANTA, 1993, 40 (01) :53-74
[9]   PROCESS MONITOR FOR AN AMMONIACAL NICKEL SOLUTION EMPLOYING AN INFRARED LIGHT-EMITTING DIODE AND A LOG-RATIO AMPLIFIER [J].
HAUSER, PC ;
RUPASINGHE, TWT ;
LUCAS, CC ;
MCCLURE, A .
ANALYST, 1995, 120 (10) :2635-2638
[10]   A flow injection renewable surface technique for cell-based drug discovery functional assays [J].
Hodder, PS ;
Ruzicka, J .
ANALYTICAL CHEMISTRY, 1999, 71 (06) :1160-1166