Accuracy of dobutamine stress echocardiography for the diagnosis of coronary artery stenosis in patients with myocardial infarction: The impact of extent and severity of left ventricular dysfunction

被引:22
作者
Elhendy, A
vanDomburg, RT
Roelandt, JRTC
Geleijnse, ML
Cornel, JH
ElSaid, GM
Fioretti, PM
机构
[1] UNIV ROTTERDAM HOSP,THORAXCTR,ROTTERDAM,NETHERLANDS
[2] ERASMUS UNIV ROTTERDAM,ROTTERDAM,NETHERLANDS
基金
芬兰科学院;
关键词
coronary artery disease; myocardial infarction; dobutamine stress echocardiography; ischaemia;
D O I
10.1136/hrt.76.2.123
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives-To assess the value of dobutamine stress echocardiography (DSE) in the prediction of the extent and location of coronary artery stenosis in symptomatic patients with old myocardial infarction and to study the impact of the severity of resting wall motion abnormalities (WMA) on the diagnostic accuracy of the test. Patients-One hundred and thirty two symptomatic patients with old myocardial infarction. Methods-DSE (up to 40 mu g/kg/min, with atropine up to 1 mg) was performed in all patients. Ischaemia was defined as new or worsened WMA. For each coronary artery, regional wall motion in the corresponding territory was classified as normal, mildly, moderately, or severely impaired according to the wall motion score index. Significant coronary stenosis was defined as greater than or equal to 50% diameter stenosis. Results-A positive DSE for ischaemia occurred in 87 of 111 patients with and three of 21 patients without coronary artery stenosis (sensitivity = 78%; CI 71 to 86, specificity = 86%; CI 79 to 92, accuracy = 80%; CI 73 to 87). The accuracy for the diagnosis of individual coronary stenosis was 69% in the presence ofnormal wall motion and 74%, 74%, and 61% respectively when there was mild, moderate, and severe WMA in the corresponding territories (P = NS). The sensitivity was higher in presence of mild or moderate WMA (73%) than with normal wall motion (53%) or severe WMA (56%, P < 0.05 in both). In territories subtended by a stenotic artery, the regional wall motion score index was not different with or without ischaemia. Conclusion-DSE had a good overall accuracy for the diagnosis of coronary artery stenosis in symptomatic patients with old myocardial infarction. The presence of resting WMA did not limit DSE as a method of eliciting myocardial ischaemia and diagnosing significant coronary artery stenosis in patients with old myocardial infarctions.
引用
收藏
页码:123 / 128
页数:6
相关论文
共 17 条
[11]   ATROPINE INCREASES THE ACCURACY OF DOBUTAMINE STRESS ECHOCARDIOGRAPHY IN PATIENTS TAKING BETA-BLOCKERS [J].
FIORETTI, PM ;
POLDERMANS, D ;
SALUSTRI, A ;
FORSTER, T ;
BELLOTTI, P ;
BOERSMA, E ;
MCNEILL, AJ ;
ELSAID, ESM ;
ROELANDT, JRTC .
EUROPEAN HEART JOURNAL, 1994, 15 (03) :355-360
[12]   ACCURACY OF DOBUTAMINE STRESS ECHOCARDIOGRAPHY IN DETECTING CORONARY-ARTERY DISEASE [J].
MARCOVITZ, PA ;
ARMSTRONG, WF .
AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (16) :1269-1273
[13]   OPTIMAL USE OF DOBUTAMINE STRESS FOR THE DETECTION AND EVALUATION OF CORONARY-ARTERY DISEASE - COMBINATION WITH ECHOCARDIOGRAPHY OR SCINTIGRAPHY, OR BOTH [J].
MARWICK, T ;
DHONDT, AM ;
BAUDHUIN, T ;
WILLEMART, B ;
WIJNS, W ;
DETRY, JM ;
MELIN, J .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (01) :159-167
[14]  
MARWICK TH, 1994, STRESS ECHOCARDIOGRA, P131
[15]   15 YEAR SURVIVAL STUDY OF PATIENTS WITH OBSTRUCTIVE CORONARY-ARTERY DISEASE [J].
PROUDFIT, WJ ;
BRUSCHKE, AVG ;
MACMILLAN, JP ;
WILLIAMS, GW ;
SONES, FM .
CIRCULATION, 1983, 68 (05) :986-997
[16]   ECHOCARDIOGRAPHIC DETECTION OF CORONARY-ARTERY DISEASE DURING DOBUTAMINE INFUSION [J].
SAWADA, SG ;
SEGAR, DS ;
RYAN, T ;
BROWN, SE ;
DOHAN, AM ;
WILLIAMS, R ;
FINEBERG, NS ;
ARMSTRONG, WF ;
FEIGENBAUM, H .
CIRCULATION, 1991, 83 (05) :1605-1614
[17]  
Takeuchi M, 1994, J Am Soc Echocardiogr, V7, P242