Validation of the Microlife Watch BP Office professional device for office blood pressure measurement according to the International protocol

被引:103
作者
Stergiou, George S. [1 ]
Tzamouranis, Dimitris [1 ]
Protogerou, Athanasios [1 ]
Nasothimiou, Efthimia [1 ]
Kapralos, Christos [1 ]
机构
[1] Third Univ, Dept Med, Hypertens Ctr, Sotiria Hosp, Athens, Greece
关键词
accuracy; European Society of Hypertension; International protocol; Microlife; office blood pressure; professional device; validation;
D O I
10.1097/MBP.0b013e3283057af6
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective To assess the accuracy of oscillometric and auscultatory blood pressure (BP) measurement taken using the professional electronic device Microlife Watch BP Office according to the European Society of Hypertension International Protocol. Methods Thirty-three participants were included for the assessment of each measurement mode (oscillometric and auscultatory). Simultaneous BP measurements were taken by two observers (mercury sphygmomanometers) four times, sequentially with three measurements taken using the tested device. Absolute observer device BP differences were calculated. For each participant the number of measurements with a difference within 5 mmHg was calculated. Results In phase 1 the device produced 32, 40 and 40 oscillometric systolic BP (SBP) measurements within 5, 10 and 15 mmHg, respectively and diastolic BP (DBP) 30, 40 and 43 (for auscultatory SBP 29, 42, 45 and DBP 33, 43, 45). In phase 2.1 the device produced 71, 90 and 96 SBP measurements within 5, 10 and 15 mmHg, respectively and DBP 71, 88 and 97 (for auscultatory SBP 72, 96, 99 and DBP 83, 96, 99). Twenty-four participants had at least two of their SBP differences within 5 mmHg and one participant had no difference within 5 mmHg, and DBP 23 and three participants, respectively (for auscultatory SBP 29 and 0 and DBP 29 and 1). Mean SBP difference was -1.4 +/- 6.3 mmHg and DBP -0.8 +/- 6.0 mmHg (auscultatory SBP -1.8 +/- 4.5 and DBP -0.4 +/- 4.0). Conclusion The Microlife Watch BP Office device used in the oscillometric or the auscultatory mode fulfills the validation criteria of the International protocol and therefore can be recommended for clinical use.
引用
收藏
页码:299 / 303
页数:5
相关论文
共 11 条
[1]   How should we measure blood pressure in the doctor's office? [J].
Gerin, W ;
Marion, RM ;
Friedman, R ;
James, GD ;
Bovbjerg, DH ;
Pickering, TG .
BLOOD PRESSURE MONITORING, 2001, 6 (05) :257-262
[2]  
HAS. Haute Autorite de Sante, 2005, PRIS CHARG PAT AD AT
[3]   Comparison between an automated and manual sphygmomanometer in a population survey [J].
Myers, Martin G. ;
Mcinnis, Natalie H. ;
Fodor, George J. ;
Leenen, Frans H. H. .
AMERICAN JOURNAL OF HYPERTENSION, 2008, 21 (03) :280-283
[4]   European Society of hypertension recommendations for conventional, ambulatory and home blood pressure measurement [J].
O'Brien, E ;
Asmar, R ;
Beilin, L ;
Imai, Y ;
Mallion, JM ;
Mancia, G ;
Mengden, T ;
Myers, M ;
Padfield, P ;
Palatini, P ;
Parati, G ;
Pickering, T ;
Redon, J ;
Staessen, J ;
Stergiou, G ;
Verdecchia, P .
JOURNAL OF HYPERTENSION, 2003, 21 (05) :821-848
[5]   Demise of the mercury sphygmomanometer and the dawning of a new era in blood pressure measurement [J].
O'Brien, E .
BLOOD PRESSURE MONITORING, 2003, 8 (01) :19-21
[6]   Working Group on Blood Pressure Monitoring of the European Society of Hypertension International Protocol for validation of blood pressure measuring devices in adults [J].
O'Brien, E ;
Pickering, T ;
Asmar, R ;
Myers, M ;
Parati, G ;
Staessen, J ;
Mengden, T ;
Imai, Y ;
Waeber, B ;
Palatini, P ;
Atkins, N ;
Gerin, W .
BLOOD PRESSURE MONITORING, 2002, 7 (01) :3-17
[7]   What will replace the mercury sphygmomanometer? [J].
Pickering, TG .
BLOOD PRESSURE MONITORING, 2003, 8 (01) :23-25
[8]  
Pickering Thomas G, 2006, J Clin Hypertens (Greenwich), V8, P394, DOI 10.1111/j.1524-6175.2006.05154.x
[9]   Office blood pressure measurement with electronic devices: Has the time come? [J].
Stergiou, George S. .
AMERICAN JOURNAL OF HYPERTENSION, 2008, 21 (03) :246-246
[10]   How to cope with unreliable office blood pressure measurement? [J].
Stergiou, GS .
AMERICAN JOURNAL OF HYPERTENSION, 2005, 18 (12) :1519-1521