Multiple echo diffusion tensor acquisition technique

被引:20
作者
Sigmund, EE [1 ]
Song, YQ [1 ]
机构
[1] Schlumberger Doll Res Ctr, Ridgefield, CT 06877 USA
关键词
DTI; MMME; multiple echo; diffusion tensor;
D O I
10.1016/j.mri.2005.10.015
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The standard method of diffusion tensor imaging (DTI) involves one diffusion-sensitizing gradient direction per acquired signal. This paper describes an alternative method in which the entire direction set required for calculating the diffusion tenser is captured in a few scans. In this method, a series of radiofrequency (RF) pulses are applied, resulting in a train of spin echoes. A pattern of applied magnetic field gradients between the RF pulses generates a different diffusion weighting in both magnitude and direction for each echo, resulting in a dataset sufficient to determine the tenser. This significantly reduces the time required for a full DTI scan and potentially allows a tradeoff of this time for image quality. In the present work, this method is demonstrated in an anisotropic diffusion phantom (asparagus). (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:7 / 18
页数:12
相关论文
共 71 条
[1]   Correlation functions for inhomogeneous magnetic field in random media with application to a dense random pack of spheres [J].
Audoly, B ;
Sen, PN ;
Ryu, S ;
Song, YQ .
JOURNAL OF MAGNETIC RESONANCE, 2003, 164 (01) :154-159
[2]   Inferring microstructural features and the physiological state of tissues from diffusion-weighted images [J].
Basser, PJ .
NMR IN BIOMEDICINE, 1995, 8 (7-8) :333-344
[3]   ESTIMATION OF THE EFFECTIVE SELF-DIFFUSION TENSOR FROM THE NMR SPIN-ECHO [J].
BASSER, PJ ;
MATTIELLO, J ;
LEBIHAN, D .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1994, 103 (03) :247-254
[4]   Anisotropic noise propagation in diffusion tensor MRI sampling schemes [J].
Batchelor, PG ;
Atkinson, D ;
Hill, DLG ;
Calamante, F ;
Connelly, A .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (06) :1143-1151
[5]   The effect of diffusion and susceptibility differences on T-2 measurements for fluids in porous media and biological tissues [J].
Borgia, GC ;
Brown, RJS ;
Fantazzini, P .
MAGNETIC RESONANCE IMAGING, 1996, 14 (7-8) :731-736
[6]  
Boujraf S, 2001, MAGN RESON MATER PHY, V13, P82
[7]  
Callaghan P. T., 1993, PRINCIPLES NUCL MAGN, P492
[8]   Isolating quantum coherences in structural imaging using intermolecular double-quantum coherence MRI [J].
Chin, CL ;
Tang, XP ;
Bouchard, LS ;
Saha, PK ;
Warren, WS ;
Wehrli, FW .
JOURNAL OF MAGNETIC RESONANCE, 2003, 165 (02) :309-314
[9]   An in vivo evaluation of the effects of local magnetic susceptibility-induced gradients on water diffusion measurements in human brain [J].
Clark, CA ;
Barker, GJ ;
Tofts, PS .
JOURNAL OF MAGNETIC RESONANCE, 1999, 141 (01) :52-61
[10]   PULSED FIELD GRADIENT STIMULATED ECHO METHODS FOR IMPROVED NMR DIFFUSION MEASUREMENTS IN HETEROGENEOUS SYSTEMS [J].
COTTS, RM ;
HOCH, MJR ;
SUN, T ;
MARKERT, JT .
JOURNAL OF MAGNETIC RESONANCE, 1989, 83 (02) :252-266