Molybdenum oxide/platinum modified glassy carbon electrode: A novel electrocatalytic platform for the monitoring of electrochemical reduction of oxygen and its biosensing applications

被引:38
作者
Cakar, Irem [1 ]
Ozdokur, K. Volkan [1 ]
Demir, Bilal [2 ]
Yavuz, Elvin [1 ]
Demirkol, Dilek Odaci [2 ]
Kocak, Suleyman [3 ]
Timur, Suna [2 ]
Ertas, Fatma Nil [1 ]
机构
[1] Ege Univ, Dept Chem, Fac Sci, TR-35100 Izmir, Turkey
[2] Ege Univ, Dept Biochem, Fac Sci, TR-35100 Izmir, Turkey
[3] Celal Bayar Univ, Dept Chem, Fac Sci & Art, TR-45030 Muradiye, Manisa, Turkey
关键词
Molybdenum trioxide; Platinum nanoparticle; Oxygen reduction; Glucose oxidase; Flow injection analysis; OXIDE THIN-FILMS; GLUCOSE-OXIDASE; NANOPARTICLES; DEPOSITION; NANOTUBES; OXIDATION; PLATINUM; BEHAVIOR; METHANOL; VANADIUM;
D O I
10.1016/j.snb.2013.04.106
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The reduction of oxygen to water is one of the most important reactions in electrochemistry with regards to the wide range of applications in electrocatalysis, metal corrosion, and fuel cell and mostly in biosensor studies. Present study describes the use of a glassy carbon electrode modified with platinum and molybdenum oxide (Pt-MoOx) in strongly acidic solutions for electrocatalytic reduction of oxygen dissolved in buffer solution for the first time. The dispersion of Pt nanoparticles on MoOx provides larger surface area and better electrocatalytic activity for oxygen reduction and the best response toward dissolved oxygen was obtained with a mole ratio of 1: 90 Pt:Mo in deposition solution. The modified surface was then used as a biosensing platform for the monitoring of oxygen consumption due to the bio-catalytic action of glucose oxidase (GO(x)) as the model enzyme. After optimization of the operational conditions, analytical characterization and application of the glucose oxidase GO(x) biosensor to flow injection analysis mode have been successfully performed. Crown Copyright (C) 2013 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:331 / 336
页数:6
相关论文
共 25 条
[21]   Electrochemical study of molybdenum oxide film electrodes [J].
Wiecek, B ;
Twardoch, U .
JOURNAL OF PHYSICS AND CHEMISTRY OF SOLIDS, 2004, 65 (2-3) :263-268
[22]   Layer-by-layer assemblies of chitosan/multi-wall carbon nanotubes and glucose oxidase for amperometric glucose biosensor applications [J].
Wu, Bao-Yan ;
Hou, Shi-Hua ;
Yu, Min ;
Qin, Xia ;
Li, Sha ;
Chen, Qiang .
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2009, 29 (01) :346-349
[23]   Amperometric biosensor based on carbon nanotubes coated with polyaniline/dendrimer-encapsulated Pt nanoparticles for glucose detection [J].
Xu, Lihuan ;
Zhu, Yihua ;
Yang, Xiaoling ;
Li, Chunzhong .
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2009, 29 (04) :1306-1310
[24]   Chitosan-ferrocene film as a platform for flow injection analysis applications of glucose oxidase and Gluconobacter oxydans biosensors [J].
Yilmaz, Ovgu ;
Demirkol, Dilek Odaci ;
Gulcemal, Suleyman ;
Kilinc, Ali ;
Timur, Suna ;
Cetinkaya, Bekir .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2012, 100 :62-68
[25]   Offline Glucose Biomonitoring in Yeast Culture by Polyamidoamine/Cysteamine-Modified Gold Electrodes [J].
Yuksel, Merve ;
Akin, Mehriban ;
Geyik, Caner ;
Demirkol, Dilek Odaci ;
Ozdemir, Caglar ;
Bluma, Arne ;
Hoepfner, Tim ;
Beutel, Sascha ;
Timur, Suna ;
Scheper, Thomas .
BIOTECHNOLOGY PROGRESS, 2011, 27 (02) :530-538