A contrast-oriented algorithm for FDG-PET-based delineation of tumour volumes for the radiotherapy of lung cancer: derivation from phantom measurements and validation in patient data

被引:134
作者
Schaefer, Andrea [1 ]
Kremp, Stephanie [2 ]
Hellwig, Dirk [1 ]
Ruebe, Christian [2 ]
Kirsch, Carl-Martin [1 ]
Nestle, Ursula [1 ]
机构
[1] Univ Saarland, Med Ctr, Dept Nucl Med, D-66421 Homburg, Germany
[2] Univ Saarland, Med Ctr, Dept Radiotherapy, D-66421 Homburg, Germany
关键词
Volume delineation; F-18-FDG; PET; Lung cancer; GTV definition; Radiotherapy; Physics; PET oncology therapy PET/CT;
D O I
10.1007/s00259-008-0875-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose An easily applicable algorithm for the FDG-PET-based delineation of tumour volumes for the radiotherapy of lung cancer was developed by phantom measurements and validated in patient data. Methods PET scans were performed (ECAT-ART tomograph) on two cylindrical phantoms (phan1, phan2) containing glass spheres of different volumes (7.4-258 ml) which were filled with identical FDG concentrations. Gradually increasing the activity of the fillable background, signal-to-background ratios from 33:1 to 2.5:1 were realised. The mean standardised uptake value (SUV) of the region-of-interest (ROI) surrounded by a 70% isocontour (mSUV(70)) was used to represent the FDG accumulation of each sphere (or tumour). Image contrast was defined as: C = (mSUV(70) - BG)/BG where BG is the mean background-SUV. For the spheres of phan1, the threshold SUVs (TS) best matching the known sphere volumes were determined. A regression function representing the relationship between TS/(mSUV(70)-BG) and C was calculated and used for delineation of the spheres in phan2 and the gross tumour volumes (GTVs) of eight primary lung tumours. These GTVs were compared to those defined using CT. Results The relationship between TS/(mSUV(70)-BG) and C is best described by an inverse regression function which can be converted to the linear relationship TS = a X mSUV(70) + b X BG. Using this algorithm, the volumes delineated in phan2 differed by only -0.4 to +0.7 mm in radius from the true ones, whilst the PET-GTVs differed by only -0.7 to +1.2 mm compared with the values determined by CT. Conclusion By the contrast-oriented algorithm presented in this study, a PET-based delineation of GTVs for primary tumours of lung cancer patients is feasible.
引用
收藏
页码:1989 / 1999
页数:11
相关论文
共 47 条
[1]  
[Anonymous], 1999, PRESCRIBING RECORDIN
[2]   ECAT ART - A continuously rotating PET camera: Performance characteristics, initial clinical studies, and installation considerations in a nuclear medicine department [J].
Bailey, DL ;
Young, H ;
Bloomfield, PM ;
Meikle, SR ;
Glass, D ;
Myers, MJ ;
Spinks, TJ ;
Watson, CC ;
Luk, P ;
Peters, AM ;
Jones, T .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1997, 24 (01) :6-15
[3]  
Baum RP, 2004, Q J NUCL MED MOL IM, V48, P119
[4]   Can a mathematical formula help define a radiation target volume using positron emission tomography?: In regard to Black et al. (Int J Radiat Oncol Biol Phys 2004;: 60:1272-1282) [J].
Bayne, M ;
MacManus, M ;
Hicks, R ;
Leong, T ;
Peters, L ;
Ball, D .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (01) :299-300
[5]   Defining a radiotherapy target with positron emission tomography [J].
Black, QC ;
Grills, IS ;
Kestin, LL ;
Wong, CYO ;
Wong, JW ;
Martinez, AA ;
Yan, D .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (04) :1272-1282
[6]  
Boellaard R, 2004, J NUCL MED, V45, P1519
[7]   Standardised FDG uptake: A prognostic factor for inoperable non-small cell lung cancer [J].
Borst, GR ;
Belderbos, JSA ;
Boellaard, R ;
Comans, EFI ;
De Jaeger, K ;
Lammertsma, AA ;
Lebesque, JV .
EUROPEAN JOURNAL OF CANCER, 2005, 41 (11) :1533-1541
[8]   Can pet provide the 3D extent of tumor motion for individualized internal target volumes? A phantom study of the limitations of CY and the promise of PET [J].
Caldwell, CB ;
Mah, K ;
Skinner, M ;
Danjoux, CE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 55 (05) :1381-1393
[9]   Automated functional image-guided radiation treatment planning for rectal cancer [J].
Ciernik, IF ;
Huser, M ;
Burger, C ;
Davis, JB ;
Szekely, G .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (03) :893-900
[10]   Radiation treatment planning with an integrated positron emission and computer tomography (PET/CT):: A feasibility study [J].
Ciernik, IF ;
Dizendorf, E ;
Baumert, BG ;
Reiner, B ;
Burger, C ;
Davis, JB ;
Lütolf, UM ;
Steinert, HC ;
Von Schulthess, GK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 57 (03) :853-863