Optimizing breast cancer treatment efficacy with intensity-modulated radiotherapy

被引:283
作者
Vicini, FA [1 ]
Sharpe, M [1 ]
Kestin, L [1 ]
Martinez, A [1 ]
Mitchell, CK [1 ]
Wallace, MF [1 ]
Matter, R [1 ]
Wong, J [1 ]
机构
[1] William Beaumont Hosp, Dept Radiat Oncol, Royal Oak, MI 48073 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2002年 / 54卷 / 05期
关键词
breast cancer; radiation; intensity-modulated radiotherapy; breast-conserving therapy;
D O I
10.1016/S0360-3016(02)03746-X
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To present our clinical experience using intensity-modulated radiation therapy (IMRT) to improve dose uniformity and treatment efficacy in patients with early-stage breast cancer treated with breast-conserving therapy. Methods and Materials: A total of 281 patients with Stage 0, I, and II breast cancer treated with breast-conserving therapy received whole breast RT after lumpectomy using our static, multileaf collimator (sMLC) IMRT technique. The technical and practical aspects of implementing this technique on a large scale in the clinic were analyzed. The clinical outcome of patients treated with this technique was also reviewed. Results: The median time required for three-dimensional alignment of the tangential fields and dosimetric IMRT planning was 40 and 45 min, respectively. The median number of sMLC segments required per patient to meet the predefined dose-volume constraints was 6 (range 3-12). The median percentage of the treatment given with open fields (no sMLC segments) was 83% (range 38-96%), and the median treatment time was <10 min. The median volume of breast receiving 105% of the prescribed dose was 11% (range 0-67.6%). The median breast volume receiving 110% of the prescribed dose was 0% (range 0-39%), and the median breast volume receiving 115% of the prescribed dose was also 0%. A total of 157 patients (56%) experienced Radiation Therapy Oncology Group Grade 0 or I acute skin toxicity; 102 patients (43%) developed Grade 11 acute skin toxicity and only 3 (1%) experienced Grade III toxicity. The cosmetic results at 12 months (95 patients analyzable) were rated as excellent/good in 94 patients (99%). No skin telengiectasias, significant fibrosis, or persistent breast pain was noted. Conclusion: The use of intensity modulation with our sMLC technique for tangential whole breast RT is an efficient method for achieving a uniform and standardized dose throughout the whole breast. Strict dose-volume constraints can be readily achieved resulting in both uniform coverage of breast tissue and a potential reduction in acute and chronic toxicities. Because the median number of sMLC segments required per patient is only 6, the treatment time is equivalent to conventional wedged-tangent treatment techniques. As a result, widespread implementation of this technology can be achieved with minimal imposition on clinic resources and time constraints. (C) 2002 Elsevier Science Inc.
引用
收藏
页码:1336 / 1344
页数:9
相关论文
共 43 条
[1]   Dosimetric improvements following 3D planning of tangential breast irradiation [J].
Aref, A ;
Thornton, D ;
Youssef, E ;
He, T ;
Tekyi-Mensah, S ;
Denton, L ;
Ezzell, G .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (05) :1569-1574
[2]   Improved delivery efficiency for step and shoot intensity modulated radiotherapy using a fast-tuning magnetron [J].
Budgell, GJ ;
Martens, C ;
Claus, F .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (11) :N253-N261
[3]   Reducing cardiac dose in post-operative irradiation of breast cancer patients: the relative importance of patient positioning and CT scan planning [J].
Canney, PA ;
Deehan, C ;
Glegg, N ;
Dickson, J .
BRITISH JOURNAL OF RADIOLOGY, 1999, 72 (862) :986-993
[4]   The use of compensators to optimise the three dimensional dose distribution in radiotherapy of the intact breast [J].
Carruthers, LJ ;
Redpath, AT ;
Kunkler, IH .
RADIOTHERAPY AND ONCOLOGY, 1999, 50 (03) :291-300
[5]   A comparison of different intensity modulation treatment techniques for tangential breast irradiation [J].
Chang, SX ;
Deschesne, KM ;
Cullip, TJ ;
Parker, SA ;
Earnhart, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (05) :1305-1314
[6]   Dosimetric comparison of treatment planning systems in irradiation of breast with tangential fields [J].
Cheng, CW ;
Das, IJ ;
Tang, W ;
Chang, S ;
Tsai, JS ;
Ceberg, C ;
DeGaspie, B ;
Singh, R ;
Fien, DA ;
Fowble, B .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 38 (04) :835-842
[7]   3-DIMENSIONAL PHOTON DOSE DISTRIBUTIONS WITH AND WITHOUT LUNG CORRECTIONS FOR TANGENTIAL BREAST INTACT TREATMENTS [J].
CHIN, LM ;
CHENG, CW ;
SIDDON, RL ;
RICE, RK ;
MIJNHEER, BJ ;
HARRIS, JR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1989, 17 (06) :1327-1335
[8]  
Chu J. C. H., 1985, INT J RADIAT ONCOL, V11, P163
[9]   A simplified intensity modulated radiation therapy technique for the breast [J].
Chui, CS ;
Hong, L ;
Hunt, M ;
McCormick, B .
MEDICAL PHYSICS, 2002, 29 (04) :522-529
[10]   Patterns of dose variability in radiation prescription of breast cancer [J].
Das, IJ ;
Cheng, CW ;
Fein, DA ;
Fowble, B .
RADIOTHERAPY AND ONCOLOGY, 1997, 44 (01) :83-89