Assessment of regional left ventricular wall parameters from short axis magnetic resonance imaging using a three-dimensional extension to the improved centerline method

被引:29
作者
Buller, VGM
VanderGeest, RJ
Kool, MD
VanderWall, EE
DeRoos, A
Reiber, JHC
机构
[1] LEIDEN UNIV,MED CTR,DEPT RADIOL,LAB CLIN & EXPT IMAGE PROC,NL-2300 RC LEIDEN,NETHERLANDS
[2] LEIDEN UNIV,MED CTR,DEPT CARDIOL,NL-2300 RC LEIDEN,NETHERLANDS
关键词
magnetic resonance imaging; left ventricular function; wall thickness; algorithms;
D O I
10.1097/00004424-199709000-00005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. Short-axis magnetic resonance images of the cardiac left ventricle, acquired in multiple slices and phases, may be used for the quantitative assessment of regional wall parameters, Conventional two-dimensional (2-D) methods for wall thickness measurement rely on information within one imaging plane, which may result in overestimation of the true thickness depending on the local direction of myocardial wall with respect to the imaging plane. METHODS. To perform wall thickness measurements truly perpendicular to the myocardial wall, a three-dimensional (3-D) wall thickness calculation algorithm has been developed based on the 2-D improved centerline method, An evaluation was performed on left ventricular-shaped software phantoms, and on the magnetic resonance (MR) imaging data obtained from 20 healthy individuals, RESULTS. The 3-D method applied to software phantoms with an angulation within 20 degrees of the true short-axis orientation demonstrated only a 1.6% overestimation of wall thickness at the mid to low slices, and a 10.6% error at the apex (2-D measurements: 8.1% and 28.6%, respectively). Three-dimensionally calculated wall thickness in the healthy individuals was systematically and significantly smaller than corresponding 2-D wall thickness (by 11.2%, 8.7%, and 2.6% at the apical, low, and mid slices, respectively). CONCLUSIONS. Cardiac wall thickness measurements from short-axis MR studies can be obtained with a higher accuracy by the newly developed 3-D approach than with the conventional 2-D approach.
引用
收藏
页码:529 / 539
页数:11
相关论文
共 21 条
[11]   QUANTITATIVE-ANALYSIS OF REGIONAL LEFT-VENTRICULAR FUNCTION AFTER MYOCARDIAL-INFARCTION IN THE PIG ASSESSED WITH CINE MAGNETIC-RESONANCE-IMAGING [J].
HOLMAN, ER ;
VLIEGEN, HW ;
VANDERGEEST, RJ ;
REIBER, JHC ;
VANDIJKMAN, PRM ;
VANDERLAARSE, A ;
DEROOS, A ;
VANDERWALL, EE .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (02) :161-169
[12]   MR-IMAGING OF REGIONAL CARDIAC-FUNCTION - LOW-PASS FILTERING OF WALL THICKNESS CURVES [J].
LAMB, HJ ;
SINGLETON, RR ;
VANDERGEEST, RJ ;
POHOST, GM ;
DEROOS, A .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (03) :498-502
[13]   ACCURATE SYSTOLIC WALL THICKENING BY NUCLEAR-MAGNETIC-RESONANCE IMAGING WITH TISSUE TAGGING - CORRELATION WITH SONOMICROMETERS IN NORMAL AND ISCHEMIC MYOCARDIUM [J].
LIMA, JAC ;
JEREMY, R ;
GUIER, W ;
BOUTON, S ;
ZERHOUNI, EA ;
MCVEIGH, E ;
BUCHALTER, MB ;
WEISFELDT, ML ;
SHAPIRO, EP ;
WEISS, JL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (07) :1741-1751
[14]   LEFT-VENTRICULAR MEASUREMENTS WITH CINE AND SPIN-ECHO MR IMAGING - A STUDY OF REPRODUCIBILITY WITH VARIANCE COMPONENT ANALYSIS [J].
PATTYNAMA, PMT ;
LAMB, HJ ;
VANDERVELDE, EA ;
VANDERWALL, EE ;
DEROOS, A .
RADIOLOGY, 1993, 187 (01) :261-268
[15]  
Schiller N B, 1989, J Am Soc Echocardiogr, V2, P358
[16]   NORMAL LEFT-VENTRICULAR DIMENSIONS AND FUNCTION - INTERSTUDY REPRODUCIBILITY OF MEASUREMENTS WITH CINE MR IMAGING [J].
SEMELKA, RC ;
TOMEI, E ;
WAGNER, S ;
MAYO, J ;
KONDO, C ;
SUZUKI, J ;
CAPUTO, GR ;
HIGGINS, CB .
RADIOLOGY, 1990, 174 (03) :763-768
[17]   DETERMINATION OF LEFT-VENTRICULAR MASS BY MAGNETIC-RESONANCE IMAGING IN HEARTS DEFORMED BY ACUTE INFARCTION [J].
SHAPIRO, EP ;
ROGERS, WJ ;
BEYAR, R ;
SOULEN, RL ;
ZERHOUNI, EA ;
LIMA, JAC ;
WEISS, JL .
CIRCULATION, 1989, 79 (03) :706-711
[18]   ADVANTAGES AND APPLICATIONS OF THE CENTERLINE METHOD FOR CHARACTERIZING REGIONAL VENTRICULAR-FUNCTION [J].
SHEEHAN, FH ;
BOLSON, EL ;
DODGE, HT ;
MATHEY, DG ;
SCHOFER, J ;
WOO, HW .
CIRCULATION, 1986, 74 (02) :293-305
[19]  
van der Geest R., 1994, COMPUTERS CARDIOLOGY, P33
[20]   MAGNETIC-RESONANCE-IMAGING DURING DOBUTAMINE STRESS FOR DETECTION AND LOCALIZATION OF CORONARY-ARTERY DISEASE - QUANTITATIVE WALL-MOTION ANALYSIS USING A MODIFICATION OF THE CENTERLINE METHOD [J].
VANRUGGE, FP ;
VANDERWALL, EE ;
SPANJERSBERG, SJ ;
DEROOS, A ;
MATHEIJSSEN, NAA ;
ZWINDERMAN, AH ;
VANDIJKMAN, PRM ;
REIBER, JHC ;
BRUSCHKE, AVG .
CIRCULATION, 1994, 90 (01) :127-138