Inhalation therapy in asthma:: Nebulizer or pressurized metered-dose inhaler with holding chamber?: In vivo comparison of lung deposition in children

被引:100
作者
Wildhaber, JH
Dore, ND
Wilson, JM
Devadason, SG
LeSouëf, PN
机构
[1] Princess Margaret Hosp Children, Dept Resp Med, Perth Med Aerosol Res Grp, Perth, WA, Australia
[2] Princess Margaret Hosp Children, Dept Nucl Med, Perth, WA, Australia
关键词
D O I
10.1016/S0022-3476(99)70323-9
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Objective: To compare lung deposition from a nebulizer and a pressurized metered-dose inhaler (pMDI)/holding chamber to determine their efficiency in aerosol delivery to children. Study design: Children with stable asthma (n = 17) aged 2 to 9 years inhaled in random order radiolabeled salbutamol from a nebulizer and a pMDI through a nonstatic holding chamber. Body and lung deposition of radiolabeled salbutamol was assessed with a gamma camera. Results: Mean (absolute dose) total lung deposition expressed as a percentage of the nebulized dose was 5.4% (108 mu g) in younger children (<4 years) and 11.1% (222 mu g) in older children (>4 years). Mean (absolute dose) total lung deposition expressed as a percentage of the metered dose was 5.4% (21.6 mu g) in younger and 9.60%, (38.4 mu g) in older children. Conclusions: For the same age groups we have shown equivalent percentages of total lung deposition of radiolabeled salbutamol aerosolized by either a nebulizer or a pMDI/holding chamber. However, the delivery rate per minute and the total dose of salbutamol deposited were significantly higher for the nebulizer.
引用
收藏
页码:28 / 33
页数:6
相关论文
共 33 条
[31]   Aerosol delivery to spontaneously breathing neonates: Spacer or nebulizer? [J].
Uhlig, T ;
Eber, E ;
Devadason, SG ;
Pemberton, P ;
Badawi, N ;
LeSouef, PN ;
Wildhaber, JH .
PEDIATRIC ASTHMA ALLERGY & IMMUNOLOGY, 1997, 11 (02) :111-117
[32]   Effect of electrostatic charge, flow, delay and multiple actuations on the in vitro delivery of salbutamol from different small volume spacers for infants [J].
Wildhaber, JH ;
Devadason, SG ;
Eber, E ;
Hayden, MJ ;
Everard, ML ;
Summers, QA ;
LeSouef, PN .
THORAX, 1996, 51 (10) :985-988
[33]   Electrostatic charge an a plastic spacer device influences the delivery of salbutamol [J].
Wildhaber, JH ;
Devadason, SG ;
Hayden, MJ ;
James, R ;
Dufty, AP ;
Fox, RA ;
Summers, QA ;
LeSouef, PN .