Continuous glucose monitoring and closed-loop systems

被引:252
作者
Hovorka, R [1 ]
机构
[1] Univ Cambridge, Addenbrookes Hosp, Dept Paediat,Diabet Modelling Grp, Cambridge CB2 2QQ, England
关键词
artificial pancreas; automated insulin delivery; continuous glucose sensing; control algorithm; insulin pump;
D O I
10.1111/j.1464-5491.2005.01672.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The last two decades have witnessed unprecedented technological progress in the development of continuous glucose sensors, resulting in the first generation of commercial glucose monitors. This has fuelled the development of prototypes of a closed-loop system based on the combination of a continuous monitor, a control algorithm, and an insulin pump. Method A review of electromechanical closed-loop approaches is presented. This is followed by a review of existing prototypes and associated glucose sensors. A literature review was undertaken from 1960 to 2004. Results Two main approaches exist. The extracorporeal s.c.-s.c. approach employs subcutaneous glucose monitoring and subcutaneous insulin delivery. The implantable i.v.-i.p. approach adopts intravenous sampling and intraperitoneal insulin delivery. Feasibility of both solutions has been demonstrated in small-scale laboratory studies using either the classical proportional-integral-derivative controller or a model predictive controller. Performance in the home setting has yet to be demonstrated. Conclusions The glucose monitor remains the main limiting factor in the development of a commercially viable closed-loop system, as presently available monitors fail to demonstrate satisfactory characteristics in terms of reliability and/or accuracy. Regulatory issues are the second limiting factor. Closed-loop systems are likely to be used first by health-care professionals in controlled environments such as intensive care units.
引用
收藏
页码:1 / 12
页数:12
相关论文
共 105 条
[1]   ARTIFICIAL ENDOCRINE PANCREAS [J].
ALBISSER, AM ;
LEIBEL, BS ;
EWART, TG ;
DAVIDOVAC, Z ;
BOTZ, CK ;
ZINGG, W .
DIABETES, 1974, 23 (05) :389-396
[2]   CLINICAL CONTROL OF DIABETES BY ARTIFICIAL PANCREAS [J].
ALBISSER, AM ;
LEIBEL, BS ;
EWART, TG ;
DAVIDOVAC, Z ;
BOTZ, CK ;
ZINGG, W ;
SCHIPPER, H ;
GANDER, R .
DIABETES, 1974, 23 (05) :397-404
[3]  
[Anonymous], 2003, Model Predictive Control
[4]  
Bélicar PS, 2003, DIABETES METAB, V29, P344
[5]   COMPUTER-SIMULATION OF PLASMA-INSULIN AND GLUCOSE DYNAMICS AFTER SUBCUTANEOUS INSULIN INJECTION [J].
BERGER, M ;
RODBARD, D .
DIABETES CARE, 1989, 12 (10) :725-736
[6]   Recording of subcutaneous glucose dynamics by a viscometric affinity sensor [J].
Beyer, U ;
Schäfer, D ;
Thomas, A ;
Aulich, H ;
Haueter, U ;
Reihl, B ;
Ehwald, R .
DIABETOLOGIA, 2001, 44 (04) :416-423
[7]  
Bode Bruce, 2004, Diabetes Technol Ther, V6, P105, DOI 10.1089/152091504773731285
[8]   IMPROVED CONTROL ALGORITHM FOR AN ARTIFICIAL BETA-CELL [J].
BOTZ, CK .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1976, 23 (03) :252-255
[9]   COMPARISON OF ALGORITHMS FOR THE CLOSED-LOOP CONTROL OF BLOOD-GLUCOSE USING THE ARTIFICIAL BETA-CELL [J].
BROEKHUYSE, HM ;
NELSON, JD ;
ZINMAN, B ;
ALBISSER, AM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1981, 28 (10) :678-687
[10]   Does continuous glucose monitoring have clinical utility in contemporary management of diabetes? [J].
Cameron, FJ ;