Does continuous glucose monitoring have clinical utility in contemporary management of diabetes?

被引:17
作者
Cameron, FJ
Ambler, GR
机构
[1] Royal Childrens Hosp, Dept Endocrinol, Melbourne, Vic, Australia
[2] Royal Childrens Hosp, Dept Diabet, Melbourne, Vic, Australia
[3] Childrens Hosp Westmead, Sydney, NSW, Australia
关键词
continuous glucose sensing; diabetes;
D O I
10.1111/j.1440-1754.2004.00307.x
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Continuous, automated and non-invasive blood glucose monitoring systems have long been a goal to assist management of diabetes mellitus. The first continuous, albeit invasive, device available in Australia is the Medtronic MiniMed Continuous Glucose Monitoring System (CGMS), which is available for physician-supervised use to give a continuous blood glucose profile (5-minutely readings, viewable only after download by the physician) for periods of 72 h. With the availability of this technology, there is a need to assess the accuracy, reproducibility and ability to detect significant clinical events (particularly hypoglycaemia) and blood glucose patterns. The question of whether this technique allows long-term improvement of metabolic control also arises. We present four case studies to illustrate the use of CGMS in clinical practice and have reviewed the rapidly emerging literature. We conclude that CGMS is a useful clinical tool in the management of diabetes mellitus, provided that it is appropriately applied and the limitations are understood.
引用
收藏
页码:79 / 84
页数:6
相关论文
共 24 条
[1]   Hypoglycemia prevalence in prepubertal children with type 1 diabetes on standard insulin regimen: Use of continuous glucose monitoring system [J].
Amin, R ;
Ross, K ;
Acerini, CL ;
Edge, JA ;
Warner, J ;
Dunger, DB .
DIABETES CARE, 2003, 26 (03) :662-667
[2]   Limitations of conventional methods of self-monitoring of blood glucose - Lessons learned from 3 days of continuous glucose sensing in pediatric patients with type 1 diabetes [J].
Boland, E ;
Monsod, T ;
Delucia, M ;
Brandt, CA ;
Fernando, S ;
Tamborlane, WV .
DIABETES CARE, 2001, 24 (11) :1858-1862
[3]   Subcutaneous glucose sensor values closely parallel blood glucose during insulin-induced hypoglycaemia [J].
Caplin, NJ ;
O'Leary, P ;
Bulsara, M ;
Davis, EA ;
Jones, TW .
DIABETIC MEDICINE, 2003, 20 (03) :238-241
[4]   Continuous subcutaneous glucose monitoring in children with type 1 diabetes [J].
Chase, HP ;
Kim, LM ;
Owen, SL ;
MacKenzie, TA ;
Klingensmith, GJ ;
Murtfeldt, R ;
Garg, SK .
PEDIATRICS, 2001, 107 (02) :222-226
[5]   Making 'sense' of diabetes: using a continuous glucose sensor in clinical practice [J].
Cheyne, E ;
Kerr, D .
DIABETES-METABOLISM RESEARCH AND REVIEWS, 2002, 18 :S43-S48
[6]   The continuous glucose monitoring system is useful for detecting unrecognized hypoglycemias in patients with type 1 and type 2 diabetes but is not better than frequent capillary glucose measurements for improving metabolic control [J].
Chico, A ;
Vidal-Ríos, P ;
Subirà, M ;
Novials, A .
DIABETES CARE, 2003, 26 (04) :1153-1157
[7]  
Davis EA, 1998, J PEDIATR ENDOCR MET, V11, P177
[8]   Accuracy of the continuous glucose monitoring system in inpatient and outpatient conditions [J].
Djakouré-Platonoff, C ;
Radermercker, R ;
Reach, G ;
Slama, G ;
Selam, JL .
DIABETES & METABOLISM, 2003, 29 (02) :159-162
[9]  
Gross T M, 2000, Diabetes Technol Ther, V2, P49, DOI 10.1089/152091500316737
[10]   Clinical performance of CGMS in type 1 diabetic patients treated by continuous subcutaneous insulin infusion using insulin analogs [J].
Guerci, B ;
Floriot, M ;
Böhme, P ;
Durain, D ;
Benichou, M ;
Jellimann, S ;
Drouin, P .
DIABETES CARE, 2003, 26 (03) :582-589