Continuous glucose monitoring and closed-loop systems

被引:252
作者
Hovorka, R [1 ]
机构
[1] Univ Cambridge, Addenbrookes Hosp, Dept Paediat,Diabet Modelling Grp, Cambridge CB2 2QQ, England
关键词
artificial pancreas; automated insulin delivery; continuous glucose sensing; control algorithm; insulin pump;
D O I
10.1111/j.1464-5491.2005.01672.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The last two decades have witnessed unprecedented technological progress in the development of continuous glucose sensors, resulting in the first generation of commercial glucose monitors. This has fuelled the development of prototypes of a closed-loop system based on the combination of a continuous monitor, a control algorithm, and an insulin pump. Method A review of electromechanical closed-loop approaches is presented. This is followed by a review of existing prototypes and associated glucose sensors. A literature review was undertaken from 1960 to 2004. Results Two main approaches exist. The extracorporeal s.c.-s.c. approach employs subcutaneous glucose monitoring and subcutaneous insulin delivery. The implantable i.v.-i.p. approach adopts intravenous sampling and intraperitoneal insulin delivery. Feasibility of both solutions has been demonstrated in small-scale laboratory studies using either the classical proportional-integral-derivative controller or a model predictive controller. Performance in the home setting has yet to be demonstrated. Conclusions The glucose monitor remains the main limiting factor in the development of a commercially viable closed-loop system, as presently available monitors fail to demonstrate satisfactory characteristics in terms of reliability and/or accuracy. Regulatory issues are the second limiting factor. Closed-loop systems are likely to be used first by health-care professionals in controlled environments such as intensive care units.
引用
收藏
页码:1 / 12
页数:12
相关论文
共 105 条
[71]   Implantable closed-loop glucose-sensing and insulin delivery: the future for insulin pump therapy [J].
Renard, E .
CURRENT OPINION IN PHARMACOLOGY, 2002, 2 (06) :708-716
[72]   Performance assessment of the Medtronic-MiniMed Continuous Glucose Monitoring System and its use for measurement of glycaemic control in Type 1 diabetic subjects [J].
Sachedina, N ;
Pickup, JC .
DIABETIC MEDICINE, 2003, 20 (12) :1012-1015
[73]   KINETIC MODELING OF THE GLUCOREGULATORY SYSTEM TO IMPROVE INSULIN THERAPY [J].
SALZSIEDER, E ;
ALBRECHT, G ;
FISCHER, U ;
FREYSE, EJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1985, 32 (10) :846-855
[74]   Improved metabolic control in diabetic adolescents using the continuous glucose monitoring system (CGMS) [J].
Schaepelynck-Bélicar, P ;
Vague, P ;
Simonin, G ;
Lassmann-Vague, V .
DIABETES & METABOLISM, 2003, 29 (06) :608-612
[75]  
Schaller H.C., 2002, DIABETES TECHNOL THE, V4, P234
[76]  
Schaller HC, 2002, DIABETES, V51, pA114
[77]  
SCHALLER HC, 2005, IN PRESS DIABET MED
[78]  
SCHALLER HC, 2003, DIABETES METAB, V39, pA2225
[79]   Direct access to interstitial fluid in adipose tissue in humans by use of open-flow microperfusion [J].
Schaupp, L ;
Ellmerer, M ;
Brunner, GA ;
Wutte, A ;
Sendlhofer, G ;
Trajanoski, Z ;
Skrabal, F ;
Pieber, TR ;
Wach, P .
AMERICAN JOURNAL OF PHYSIOLOGY-ENDOCRINOLOGY AND METABOLISM, 1999, 276 (02) :E401-E408
[80]   The Continuous Glucose Monitoring System (CGMS) in type 1 diabetic children is the way to reduce hypoglycemic risk [J].
Schiaffini, R ;
Ciampalini, P ;
Fierabracci, A ;
Spera, S ;
Borrelli, P ;
Bottazzo, GF ;
Crinò, A .
DIABETES-METABOLISM RESEARCH AND REVIEWS, 2002, 18 (04) :324-329