Visualisation of intracerebral haemorrhage with flat-detector CT compared to multislice CT: results in 44 cases

被引:66
作者
Struffert, Tobias [1 ]
Richter, Gregor [1 ]
Engelhorn, Tobias [1 ]
Doelken, Marc [1 ]
Goelitz, Philipp [1 ]
Kalender, Willi A. [2 ]
Ganslandt, Oliver [3 ]
Doerfler, Arnd [1 ]
机构
[1] Univ Erlangen Nurnberg, Dept Neuroradiol, D-91054 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Inst Med Phys, D-91052 Erlangen, Germany
[3] Univ Erlangen Nurnberg, Dept Neurosurg, D-91054 Erlangen, Germany
关键词
Flat-detector computed tomography; Multisclice computed tomography; Intracerebral haemorrhage; Computed tomography; COMPUTED-TOMOGRAPHY;
D O I
10.1007/s00330-008-1183-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of the study was to test the reliability of intracerebral haemorrhage (ICH) detection with C-arm-mounted flat-detector computed tomography (FD-CT) in the angio suite as compared to multislice CT (MSCT). In this study 44 patients with 45 ICH were included. All patients were investigated with MSCT and FD-CT during angiographic evaluation. As a control group we included 16 patients without ICH. In each haematoma we assessed volumetric data of the ICH and counted the numbers of ICH-positive slices. Using interobserver ratings, we additionally investigated the potential of FD-CT to serve as a diagnostic tool to detect ICH. In FD-CT three haematomas were not detected because of motion and beam-hardening artefacts in the region close to the skull base. The r value for the degree of interobserver agreement for the number of slices was 0.95 for MSCT and 0.94 for FD-CT. Measurements of the area and the calculated volume of the ICH showed high inter- and intraobserver agreement. Our results indicate that FD-CT is a helpful tool in the daily emergency management of ICH patients as detection of ICH was found to be nearly as reliable as in MSCT. Limitations of this technology are motion and beam-hardening artefacts that may mask small haematomas located in the posterior fossa or the skull base.
引用
收藏
页码:619 / 625
页数:7
相关论文
共 14 条
[1]   Experimental study of intracranial hematoma detection with flat panel detector C-arm CT [J].
Arakawa, H. ;
Marks, M. P. ;
Do, H. M. ;
Bouley, D. M. ;
Strobel, N. ;
Moore, T. ;
Fahrig, R. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (04) :766-772
[2]  
Brisman JL, 2005, NEUROSURGERY, V57, P1103, DOI 10.1227/01.NEU.0000185631.20246.1A
[3]   Severe intracranial bleedings during endovascular procedures:: outcome of surgically treated patients [J].
Carvi y Nievas, Mario ;
Haas, Eberhard ;
Hoellerhage, Hans-Georg .
NEUROLOGICAL RESEARCH, 2007, 29 (01) :81-90
[4]   Flat-panel detector volumetric CT for visualization of subarachnoid hemorrhage and ventricles: preliminary results compared to conventional CT [J].
Doelken, M. ;
Struffert, T. ;
Richter, G. ;
Engelhorn, T. ;
Nimsky, C. ;
Ganslandt, O. ;
Hammen, T. ;
Doerfler, A. .
NEURORADIOLOGY, 2008, 50 (06) :517-523
[5]   Myelography using flat panel volumetric computed tomography - A comparative study in patients with lumbar spinal stenosis [J].
Engelhorn, Tobias ;
Rennert, Janine ;
Richter, Gregor ;
Struffert, Tobias ;
Ganslandt, Oliver ;
Doerfler, Arnd .
SPINE, 2007, 32 (18) :E523-E527
[6]   Spontaneous intracerebral haemorrhage in adults:: a literature overview [J].
Haenggi, D. ;
Steiger, H. -J. .
ACTA NEUROCHIRURGICA, 2008, 150 (04) :371-379
[7]  
Heran NS, 2006, AM J NEURORADIOL, V27, P330
[8]  
Kalender WA, 2003, RADIOLOGE, V43, P379, DOI 10.1007/s00117-003-0897-4
[9]   Flat-detector computed tomography (FD-CT) [J].
Kalender, Willi A. ;
Kyriakou, Yiannis .
EUROPEAN RADIOLOGY, 2007, 17 (11) :2767-2779
[10]   FACTORS AFFECTING THE PROGNOSIS IN THALAMIC HEMORRHAGE [J].
KWAK, R ;
KADOYA, S ;
SUZUKI, T .
STROKE, 1983, 14 (04) :493-500