Flat-detector computed tomography (FD-CT)

被引:261
作者
Kalender, Willi A. [1 ]
Kyriakou, Yiannis [1 ]
机构
[1] Univ Erlangen Nurnberg, Inst Med Phys, D-91052 Erlangen, Germany
关键词
computed tomography; angiography; interventions; flat detectors; C-arm systems; ARM IMAGE INTENSIFIER; CONE-BEAM CT; PANEL DETECTOR; ACTIVE-MATRIX; VOLUME CT; PERFORMANCE; RADIATION; RECONSTRUCTION; CALIBRATION; QUALITY;
D O I
10.1007/s00330-007-0651-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Flat-panel detectors or, synonymously, flat detectors (FDs) have been developed for use in radiography and fluoroscopy with the defined goal to replace standard X-ray film, film-screen combinations and image intensifiers by an advanced sensor system. FD technology in comparison to X-ray film and image intensifiers offers higher dynamic range, dose reduction, fast digital readout and the possibility for dynamic acquisitions of image series, yet keeping to a compact design. It appeared logical to employ FD designs also for computed tomography (CT) imaging. Respective efforts date back a few years only, but FD-CT has meanwhile become widely accepted for interventional and intra-operative imaging using C-arm systems. FD-CT provides a very efficient way of combining two-dimensional (2D) radiographic or fluoroscopic and 3D CT imaging. In addition, FD technology made its way into a number of dedicated CT scanner developments, such as scanners for the maxillo-facial region or for micro-CT applications. This review focuses on technical and performance issues of FD technology and its full range of applications for CT imaging. A comparison with standard clinical CT is of primary interest. It reveals that FD-CT provides higher spatial resolution, but encompasses a number of disadvantages, such as lower dose efficiency, smaller field of view and lower temporal resolution. FD-CT is not aimed at challenging standard clinical CT as regards to the typical diagnostic examinations; but it has already proven unique for a number of dedicated CT applications, offering distinct practical advantages, above all the availability of immediate CT imaging in the interventional suite or the operating room.
引用
收藏
页码:2767 / 2779
页数:13
相关论文
共 58 条
[1]   Strategies to improve the signal and noise performance of active matrix, flat-panel imagers for diagnostic x-ray applications [J].
Antonuk, LE ;
Jee, KW ;
El-Mohri, Y ;
Maolinbay, M ;
Nassif, S ;
Rong, X ;
Zhao, Q ;
Siewerdsen, JH ;
Street, RA ;
Shah, KS .
MEDICAL PHYSICS, 2000, 27 (02) :289-306
[2]  
Benndorf G, 2005, AM J NEURORADIOL, V26, P1813
[3]   Lag and ghosting in a clinical flat-panel selenium digital mammography system [J].
Bloomquist, Aili K. ;
Yaffe, Martin J. ;
Mawdsley, Gordon E. ;
Hunter, David M. ;
Beideck, Daniel J. .
MEDICAL PHYSICS, 2006, 33 (08) :2998-3005
[4]   Technique factors and their relationship to radiation dose in pendant geometry breast CT [J].
Boone, JM ;
Kwan, ALC ;
Seibert, JA ;
Shah, N ;
Lindfors, KK ;
Nelson, TR .
MEDICAL PHYSICS, 2005, 32 (12) :3767-3776
[5]   Dedicated breast CT: Radiation dose and image quality evaluation [J].
Boone, JM ;
Nelson, TR ;
Lindfors, KK ;
Seibert, JA .
RADIOLOGY, 2001, 221 (03) :657-667
[6]  
CHANG CHJ, 1978, RADIOLOGY, V129, P209
[7]   Intraoperative cone-beam CT for guidance of head and neck surgery: Assessment of dose and image quality using a C-arm prototype [J].
Daly, M. J. ;
Siewerdsen, J. H. ;
Moseley, D. J. ;
Jaffray, D. A. ;
Irish, J. C. .
MEDICAL PHYSICS, 2006, 33 (10) :3767-3780
[8]   An improved analytical model for CT dose simulation with a new look at the theory of CT dose [J].
Dixon, RL ;
Munley, MT ;
Bayram, E .
MEDICAL PHYSICS, 2005, 32 (12) :3712-3728
[9]  
Dixon RL, 2003, MED PHYS, V30, P1272, DOI 10.1118/1.1576952
[10]  
Doerfler A, 2001, AM J NEURORADIOL, V22, P1825