Flat-detector computed tomography (FD-CT)

被引:261
作者
Kalender, Willi A. [1 ]
Kyriakou, Yiannis [1 ]
机构
[1] Univ Erlangen Nurnberg, Inst Med Phys, D-91052 Erlangen, Germany
关键词
computed tomography; angiography; interventions; flat detectors; C-arm systems; ARM IMAGE INTENSIFIER; CONE-BEAM CT; PANEL DETECTOR; ACTIVE-MATRIX; VOLUME CT; PERFORMANCE; RADIATION; RECONSTRUCTION; CALIBRATION; QUALITY;
D O I
10.1007/s00330-007-0651-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Flat-panel detectors or, synonymously, flat detectors (FDs) have been developed for use in radiography and fluoroscopy with the defined goal to replace standard X-ray film, film-screen combinations and image intensifiers by an advanced sensor system. FD technology in comparison to X-ray film and image intensifiers offers higher dynamic range, dose reduction, fast digital readout and the possibility for dynamic acquisitions of image series, yet keeping to a compact design. It appeared logical to employ FD designs also for computed tomography (CT) imaging. Respective efforts date back a few years only, but FD-CT has meanwhile become widely accepted for interventional and intra-operative imaging using C-arm systems. FD-CT provides a very efficient way of combining two-dimensional (2D) radiographic or fluoroscopic and 3D CT imaging. In addition, FD technology made its way into a number of dedicated CT scanner developments, such as scanners for the maxillo-facial region or for micro-CT applications. This review focuses on technical and performance issues of FD technology and its full range of applications for CT imaging. A comparison with standard clinical CT is of primary interest. It reveals that FD-CT provides higher spatial resolution, but encompasses a number of disadvantages, such as lower dose efficiency, smaller field of view and lower temporal resolution. FD-CT is not aimed at challenging standard clinical CT as regards to the typical diagnostic examinations; but it has already proven unique for a number of dedicated CT applications, offering distinct practical advantages, above all the availability of immediate CT imaging in the interventional suite or the operating room.
引用
收藏
页码:2767 / 2779
页数:13
相关论文
共 58 条
[51]   Cone-beam computed tomography with a flat-panel imager: Magnitude and effects of x-ray scatter [J].
Siewerdsen, JH ;
Jaffray, DA .
MEDICAL PHYSICS, 2001, 28 (02) :220-231
[52]   Reconstruction from truncated projections in CT using adaptive detruncation [J].
Sourbelle, K ;
Kachelriess, M ;
Kalender, WA .
EUROPEAN RADIOLOGY, 2005, 15 (05) :1008-1014
[53]  
VOLLMAR S, 2007, IN PRESS EUR RADIO S
[54]   Geometric misalignment and calibration in cone-beam tomography [J].
von Smekal, L ;
Kachelriess, M ;
Stepina, E ;
Kalender, WA .
MEDICAL PHYSICS, 2004, 31 (12) :3242-3266
[55]   Feasibility of real time dual-energy imaging based on a flat panel detector for coronary artery calcium quantification [J].
Xu, Tong ;
Ducote, Justin L. ;
Wong, Jerry T. ;
Molloi, Sabee .
MEDICAL PHYSICS, 2006, 33 (06) :1612-1622
[56]   Low contrast 3D-reconstruction from C-arm data [J].
Zellerhoff, M ;
Scholz, B ;
Rührnschopf, EP ;
Brunner, T .
MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 :646-655
[57]   Large area mercuric iodide and lead iodide X-ray detectors for medical and non-destructive industrial imaging [J].
Zentai, G. ;
Schieber, M. ;
Partain, L. ;
Pavlyuchkova, R. ;
Proano, C. .
JOURNAL OF CRYSTAL GROWTH, 2005, 275 (1-2) :E1327-E1331
[58]   Ghosting caused by bulk charge trapping in direct conversion flat-panel detectors using amorphous selenium [J].
Zhao, W ;
DeCrescenzo, G ;
Kasap, SO ;
Rowlands, JA .
MEDICAL PHYSICS, 2005, 32 (02) :488-500