Low contrast 3D-reconstruction from C-arm data

被引:70
作者
Zellerhoff, M [1 ]
Scholz, B [1 ]
Rührnschopf, EP [1 ]
Brunner, T [1 ]
机构
[1] Siemens AG, Med Solut, Forchheim, Germany
来源
MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2 | 2005年 / 5745卷
关键词
3D-reconstruction; cone beam CT; flat panel detector; C-arm; low contrast imaging; scatter correction; beam hardening correction; ring corrections; quantization; ALGORITHM; RECONSTRUCTION; RESOLUTION; OBJECTS; NOISE;
D O I
10.1117/12.593433
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The integration of 3D-imaging functionality into C-arm. systems combines advantages of interventional X-ray systems, e.g good patient access and live fluoroscopy, with 3D imaging capabilities similar to those of a CT-scanner. To date 3D-imaging with a C-arm system has been mainly used to visualize high contrast objects. However, the advent of high quality flat panel detectors improves the low contrast imaging capabilities. We discuss the influence of scattered radiation, beam hardening, truncated projections, quantization and detector recording levels on the image quality. Subsequently, we present algorithms and methods to correct these effects in order to achieve low contrast resolution. The performance of our pre- and post-reconstructive correction procedures is demonstrated by first clinical cases.
引用
收藏
页码:646 / 655
页数:10
相关论文
共 21 条
  • [1] Barrett H.H., 1981, RADIOLOGICAL IMAGING, V2
  • [2] BAYESIAN IMAGE ESTIMATION OF DIGITAL CHEST RADIOGRAPHY - INTERDEPENDENCE OF NOISE, RESOLUTION, AND SCATTER FRACTION
    BAYDUSH, AH
    FLOYD, CE
    [J]. MEDICAL PHYSICS, 1995, 22 (08) : 1255 - 1261
  • [3] Comparison of contrast-to-noise ratios for Bayesian processing and grids in digital chest radiography
    Baydush, AH
    Gehm, WC
    Floyd, CE
    [J]. MEDICAL IMAGING 1999: IMAGE PROCESSING, PTS 1 AND 2, 1999, 3661 : 665 - 672
  • [4] Improved image quality with Bayesian image processing in digital mammography
    Baydush, AH
    Floyd, CE
    [J]. MEDICAL IMAGING 2000: IMAGE PROCESSING, PTS 1 AND 2, 2000, 3979 : 781 - 786
  • [5] PRACTICAL CONE-BEAM ALGORITHM
    FELDKAMP, LA
    DAVIS, LC
    KRESS, JW
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06): : 612 - 619
  • [6] RECONSTRUCTION OF OBJECTS FROM INCOMPLETE PROJECTIONS
    GORE, JC
    LEEMAN, S
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (01) : 129 - 136
  • [7] CORRECTION FOR BEAM HARDENING IN COMPUTED-TOMOGRAPHY
    HERMAN, GT
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (01) : 81 - 106
  • [8] A novel reconstruction algorithm to extend the CT scan field-of-view
    Hsieh, J
    Chao, E
    Thibault, J
    Grekowicz, B
    Horst, A
    McOlash, S
    Myers, TJ
    [J]. MEDICAL PHYSICS, 2004, 31 (09) : 2385 - 2391
  • [9] An iterative approach to the beam hardening correction in cone beam CT
    Hsieh, J
    Molthen, RC
    Dawson, CA
    Johnson, RH
    [J]. MEDICAL PHYSICS, 2000, 27 (01) : 23 - 29
  • [10] JOSEPH PM, 1997, MED PHYS, V24