Low Wear of a Second-generation Highly Crosslinked Polyethylene Liner: A 5-year Radiostereometric Analysis Study

被引:36
作者
Callary, Stuart A. [1 ,2 ]
Field, John R. [2 ]
Campbell, David G. [3 ]
机构
[1] Univ Adelaide, Ctr Orthopaed & Trauma Res, Adelaide, SA 5000, Australia
[2] Royal Adelaide Hosp, Adelaide, SA 5000, Australia
[3] Wakefield Orthopaed Clin, Adelaide, SA, Australia
关键词
TOTAL HIP-ARTHROPLASTY; RSA; REPLACEMENTS; RADIOGRAPHS; OSTEOLYSIS; ACCURACY;
D O I
10.1007/s11999-013-3188-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
A sequentially irradiated and annealed, second-generation highly crosslinked polyethylene (XLPE) liner was introduced clinically in 2005 to reduce in vivo oxidation. This liner design has also been shown to reduce wear in vitro when compared with conventional and first-generation crosslinked liners. To date, there is only one study reporting an in vivo wear rate of this liner at 5 years' followup. However, that study used measurements made from plain radiographs, which have limited sensitivity, particularly when monitoring very low amounts of wear. What is the amount and direction of wear at 5 years using radiostereometric analysis (RSA) in patients who had THAs that included second-generation XLPE? We prospectively reviewed 21 patients who underwent primary cementless THA with the same design of XLPE acetabular liner and 32-mm articulation. Tantalum markers were inserted during surgery and all patients had RSA radiographs at 1 week, 6 months, and 1, 2, and 5 years postoperatively. Femoral head penetration within the acetabular component was measured with UmRSA(A (R)) software. One patient died and two had incomplete radiographs leaving 18 radiographic series for analysis. The mean amounts of proximal, two-dimensional, and three-dimensional head penetration between 1 week and 5 years were 0.018, 0.071, and 0.149 mm, respectively. The mean proximal, two-dimensional, and three-dimensional wear rates calculated between 1 year and 5 years were all less than 0.001 mm/year with no patient recording a wear rate of more than 0.040 mm/year. The head penetration of a second-generation XLPE liner remained low at 5 years and the wear rate calculated after the first year was low in all directions. This low level of wear remains encouraging for the future clinical performance of this material.
引用
收藏
页码:3596 / 3600
页数:5
相关论文
共 17 条
[1]
RSA wear measurements with or without markers in total hip arthroplasty [J].
Börlin, N ;
Röhrl, SM ;
Bragdon, CR .
JOURNAL OF BIOMECHANICS, 2006, 39 (09) :1641-1650
[2]
Comparison of femoral head penetration using RSA and the Martell method [J].
Bragdon, Charles R. ;
Martell, John M. ;
Greene, Meridith E. ;
Estok, Daniel M., II ;
Thanner, Jonas ;
Karrholm, Johan ;
Harris, William H. ;
Malchau, Henrik .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (448) :52-57
[3]
Experimental assessment of precision and accuracy of radio stereometric analysis for the determination of polyethylene wear in a total hip replacement model [J].
Bragdon, CR ;
Malchau, H ;
Yuan, XH ;
Perinchief, R ;
Kärrholm, J ;
Börlin, N ;
Estok, DM ;
Harris, WH .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2002, 20 (04) :688-695
[4]
Wear of a 5 Megarad Cross-linked Polyethylene Liner: A 6-year RSA Study [J].
Callary, Stuart A. ;
Campbell, David G. ;
Mercer, Graham ;
Nilsson, Kjell G. ;
Field, John R. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2013, 471 (07) :2238-2244
[5]
Second-generation Highly Cross-linked X3™ Polyethylene Wear: A Preliminary Radiostereometric Analysis Study [J].
Campbell, David G. ;
Field, John R. ;
Callary, Stuart A. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (10) :2704-2709
[6]
Second-generation Annealed Highly Cross-linked Polyethylene Exhibits Low Wear [J].
D'Antonio, James A. ;
Capello, William N. ;
Ramakrishnan, Rama .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (06) :1696-1704
[7]
5-year experience of highly cross-linked polyethylene in cemented and uncemented sockets -: Two randomized studies using radiostereometric analysis [J].
Digas, Georgios ;
Karrholm, Johan ;
Thanner, Jonas ;
Herberts, Peter .
ACTA ORTHOPAEDICA, 2007, 78 (06) :746-754
[8]
A literature review of the association between wear rate and osteolysis in total hip arthroplasty [J].
Dumbleton, JH ;
Manley, MT ;
Edidin, AA .
JOURNAL OF ARTHROPLASTY, 2002, 17 (05) :649-661
[9]
The basis for a second-generation highly cross-linked UHMWPE [J].
Dumbleton, John H. ;
D'Antonio, James A. ;
Manley, Michael T. ;
Capello, William N. ;
Wang, Aiguo .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (453) :265-271
[10]
Accuracy of measurement of polyethylene wear with use of radiographs of total hip replacements [J].
Ebramzadeh, E ;
Sangiorgio, SN ;
Lattuada, F ;
Kang, JS ;
Chiesa, R ;
McKellop, HA ;
Dorr, LD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (12) :2378-2384