Comparison of femoral head penetration using RSA and the Martell method

被引:44
作者
Bragdon, Charles R.
Martell, John M.
Greene, Meridith E.
Estok, Daniel M., II
Thanner, Jonas
Karrholm, Johan
Harris, William H.
Malchau, Henrik
机构
[1] Massachusetts Gen Hosp, Dept Orthopaed Surg, Orthopaed Biomech & Biomat Lab, Boston, MA 02114 USA
[2] Massachusetts Gen Hosp, Dept Orthopaed Surg, Adult Reconstruct Unit, Boston, MA 02114 USA
[3] Harvard Univ, Sch Med, Boston, MA USA
[4] Univ Chicago, Sect Orthopaed, Chicago, IL 60637 USA
[5] Univ Gothenburg, Inst Surg Sci, Dept Orthoped, Gothenburg, Sweden
关键词
D O I
10.1097/01.blo.0000224018.88410.83
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Radiostereometry has high precision and accuracy measuring polyethylene wear in total hip arthroplasty but requires a specialized setup. The Martell method is simpler and can be used on larger populations. The hypothesis that the radiostereometry analysis and the Martell analysis would yield comparable wear data from the same group of patients having total hip arthroplasty was tested. A group of twenty-five total hip arthroplasty patients who had both radiostereometry and standard anterior-posterior pelvic and cross-table lateral radiographs of sufficient quality for analysis were identified. The films were taken at postoperative periods of 6 weeks, 1 year, 2 years, and 5 years. Femoral head penetration was measured by both methods at each time point. The median penetration rates measured by each method decreased over time. Penetration results were affected by method of analysis, time, and dimension, with greater penetration for Martell compared with radiostereometry at each time point, greater penetration with increasing time for each method, and larger three-dimensional magnitude compared with two-dimensional analysis.
引用
收藏
页码:52 / 57
页数:6
相关论文
共 26 条
[1]
[Anonymous], CLIN ORTHOPAEDICS
[2]
INSTABILITY AND WEAR OF TOTAL HIP PROSTHESES DETERMINED WITH ROENTGEN STEREOPHOTOGRAMMETRY [J].
BALDURSSON, H ;
EGUND, N ;
HANSSON, LI ;
SELVIK, G .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1979, 95 (04) :257-263
[3]
The precision of radiostereometric measurements.: Manual vs. digital measurements [J].
Börlin, N ;
Thien, T ;
Kärrholm, J .
JOURNAL OF BIOMECHANICS, 2002, 35 (01) :69-79
[4]
Comparison of two digital radio stereometric analysis methods in the determination of femoral head penetration in a total hip replacement phantom [J].
Bragdon, CR ;
Estok, DM ;
Malchau, H ;
Kärrholm, J ;
Yuan, XH ;
Bourne, R ;
Veldhoven, J ;
Harris, WH .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2004, 22 (03) :659-664
[5]
Callaghan John J, 2003, Iowa Orthop J, V23, P1
[6]
CLARKE IC, 1976, CLIN ORTHOP RELAT R, P126
[7]
Three-dimensional polyethylene wear of a press-fit titanium prosthesis - Factors influencing generation of polyethylene debris [J].
Devane, PA ;
Horne, JG ;
Martin, K ;
Coldham, G ;
Krause, B .
JOURNAL OF ARTHROPLASTY, 1997, 12 (03) :256-266
[8]
DEVANE PA, 1995, CLIN ORTHOP RELAT R, V319, P317
[9]
DEVANE PA, 1999, CLIN ORTHOP RELAT R, V369, P59
[10]
ROENTGEN STEREOPHOTOGRAMMETRIC SHORT-TERM ANALYSIS OF GROWTH-RATE IN CHILDREN OPERATED FOR CROHNS-DISEASE [J].
HILDEBRAND, H ;
ARONSON, S ;
KULLENDORFF, CM ;
SELVIK, G .
ACTA PAEDIATRICA SCANDINAVICA, 1991, 80 (10) :917-923