Cerebral microemboli during cardiopulmonary bypass: Increased emboli during perfusionist interventions

被引:111
作者
Taylor, RL
Borger, MA
Weisel, RD
Fedorko, L
Feindel, CM
机构
[1] Toronto Hosp, Div Cardiovasc Surg, Toronto, ON M5G 2C4, Canada
[2] Toronto Hosp, Div Cardiac Anesthesia, Toronto, ON M5G 2C4, Canada
关键词
D O I
10.1016/S0003-4975(99)00475-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Microemboli to the cerebral circulation occur during cardiopulmonary bypass (CPB) and can contribute to postoperative neurologic dysfunction. Cerebral microemboli are known to occur during specific surgical interventions, but the source of a large proportion of emboli remains unexplained. We investigated whether interventions by the perfusionist could account for the appearance of cerebral microemboli. Methods. Transcranial Doppler ultrasonography was used to continuously monitor the middle cerebral artery of 18 patients undergoing coronary artery bypass grafting. The CPB circuit consisted of a softshell venous reservoir, a hollow-fiber membrane oxygenator, and a 32-mu m arterial filter. The mean embolic rate was calculated for three time periods: (1) during surgical interventions (aortic cannulation and decannulation, cross-clamp application and removal, CPB start and end, and start of cardiac ejection); (2) during perfusionist interventions (blood sampling and drug administration into the venous reservoir); and (3) during baseline (all other time periods during CPB). Results. Microemboli were detected in all patients (mean +/- standard deviation, 207 +/- 142 per patient, median, 132). The number of emboli per minute was significantly (p < 0.001) higher during perfusionist interventions (6.9 +/- 4.5) than during surgical interventions (1.5 +/- 1.5) or during baseline (0.4 +/- 0.5). Drug administration resulted in a higher embolic rate than blood sampling. Conclusions. Interventions by the perfusionist account for a large proportion of previously unexplained cerebral microemboli during CPB. These emboli likely represent air bubbles that are not eliminated by the arterial line filter. Although further studies of additional types of CPB circuits are required, we believe that air in the venous reservoir should be avoided whenever possible to minimize the risk of neurologic injury. (C) 1999 by The Society of Thoracic Surgeons.
引用
收藏
页码:89 / 93
页数:5
相关论文
共 24 条
[1]   Impact of embolization during coronary artery bypass grafting on outcome and length of stay [J].
Barbut, D ;
Lo, YW ;
Gold, JP ;
Trifiletti, RR ;
Yao, FSF ;
Hager, DN ;
Hinton, RB ;
Isom, OW .
ANNALS OF THORACIC SURGERY, 1997, 63 (04) :998-1002
[2]  
Barbut D, 1997, ANN THORAC SURG, V63, P1262
[3]   CEREBRAL EMBOLI DETECTED DURING BYPASS-SURGERY ARE ASSOCIATED WITH CLAMP REMOVAL [J].
BARBUT, D ;
HINTON, RB ;
SZATROWSKI, TP ;
HARTMAN, GS ;
BRUEFACH, M ;
WILLIAMSRUSSO, P ;
CHARLSON, ME ;
GOLD, JP .
STROKE, 1994, 25 (12) :2398-2402
[4]   MACROEMBOLI AND MICROEMBOLI DURING CARDIOPULMONARY BYPASS [J].
BLAUTH, CI .
ANNALS OF THORACIC SURGERY, 1995, 59 (05) :1300-1303
[5]  
Borger MA, 1998, CIRCULATION, V98, pII137
[6]   MICROEMBOLI DURING CORONARY-ARTERY BYPASS-GRAFTING - GENESIS AND EFFECT AN OUTCOME [J].
CLARK, RE ;
BRILLMAN, J ;
DAVIS, DA ;
LOVELL, MR ;
PRICE, TRP ;
MAGOVERN, GJ .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1995, 109 (02) :249-258
[7]   Bigated transcranial Doppler for the detection of clinically silent circulating emboli in normal persons and patients with prosthetic cardiac valves [J].
Droste, DW ;
Hagedorn, G ;
Notzold, A ;
Siemens, HJ ;
Sievers, HH ;
Kaps, M .
STROKE, 1997, 28 (03) :588-592
[8]   Automated intraoperative detection of Doppler microembolic signals using the Bigate approach [J].
Georgiadis, D ;
Wenzel, A ;
Zerkowski, HR ;
Zierz, S ;
Lindner, A .
STROKE, 1998, 29 (01) :137-139
[9]   A novel technique for identification of Doppler microembolic signals based on the coincidence method - In vitro and in vivo evaluation [J].
Georgiadis, D ;
Goeke, J ;
Hill, M ;
Konig, M ;
Nabavi, DG ;
Stogbauer, F ;
Zunker, P ;
Ringelstein, EB .
STROKE, 1996, 27 (04) :683-686
[10]   Risk factors and solutions for the development of neurobehavioral changes after coronary artery bypass grafting [J].
Hammon, JW ;
Stump, DA ;
Kon, ND ;
Cordell, AR ;
Hudspeth, AS ;
Oaks, TE ;
Brooker, RF ;
Rogers, AT ;
Hilbawi, R ;
Coker, LH ;
Troost, BT .
ANNALS OF THORACIC SURGERY, 1997, 63 (06) :1613-1618