Automated intraoperative detection of Doppler microembolic signals using the Bigate approach

被引:19
作者
Georgiadis, D
Wenzel, A
Zerkowski, HR
Zierz, S
Lindner, A
机构
[1] Univ Halle Wittenberg, Dept Neurol, D-06122 Halle, Germany
[2] Univ Halle Wittenberg, Dept Cardiothorac Surg, D-06122 Halle, Germany
关键词
cardiopulmonary bypass; embolism; ultrasonography; Doppler;
D O I
10.1161/01.STR.29.1.137
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose-We undertook this study to evaluate the performance of an automated detection software in the detection of Doppler microembolic signals (MES) during cardiac surgery. Methods-Intraoperative monitoring was performed over two spatially separated vessel segments of each middle cerebral artery in 18 patients undergoing coronary artery bypass surgery (n=16) or cardiac valve replacement (n=2). All monitoring sessions were saved on digital audiotape and subsequently played back to the same ultrasound machine, set up to automatically detect MES by evaluating the temporary delay in their appearance between the: two segments, in the presence of an experienced examiner. Software sensitivity and specificity in MES detection were then evaluated, with the results of the human observer considered the gold standard. Results-A total of 44 933 high-intensity signals (artifacts and MES) were evaluated. Overall sensitivity and specificity of the software, with the human observer considered the gold standard, were 64% and 78.5%, respectively, ranging from 54% to 96% and from 74% to 90% in individual patients. When the overall results of the software were compared with those of the human observer, kappa was 0.72. Conclusions-The tested software displayed a satisfactory specificity. Provided that the sensitivity is further improved, it could provide a valuable tool in intraoperative monitoring.
引用
收藏
页码:137 / 139
页数:3
相关论文
共 14 条
[1]   Impact of embolization during coronary artery bypass grafting on outcome and length of stay [J].
Barbut, D ;
Lo, YW ;
Gold, JP ;
Trifiletti, RR ;
Yao, FSF ;
Hager, DN ;
Hinton, RB ;
Isom, OW .
ANNALS OF THORACIC SURGERY, 1997, 63 (04) :998-1002
[2]   MICROEMBOLI DURING CORONARY-ARTERY BYPASS-GRAFTING - GENESIS AND EFFECT AN OUTCOME [J].
CLARK, RE ;
BRILLMAN, J ;
DAVIS, DA ;
LOVELL, MR ;
PRICE, TRP ;
MAGOVERN, GJ .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1995, 109 (02) :249-258
[3]   Bigated transcranial Doppler for the detection of clinically silent circulating emboli in normal persons and patients with prosthetic cardiac valves [J].
Droste, DW ;
Hagedorn, G ;
Notzold, A ;
Siemens, HJ ;
Sievers, HH ;
Kaps, M .
STROKE, 1997, 28 (03) :588-592
[4]  
Fleiss J. L., 1981, STAT METHODS RATES P, P598
[5]   A novel technique for identification of Doppler microembolic signals based on the coincidence method - In vitro and in vivo evaluation [J].
Georgiadis, D ;
Goeke, J ;
Hill, M ;
Konig, M ;
Nabavi, DG ;
Stogbauer, F ;
Zunker, P ;
Ringelstein, EB .
STROKE, 1996, 27 (04) :683-686
[6]   QUANTIFICATION OF ULTRASOUND EMBOLI SIGNALS IN PATIENTS WITH CARDIAC AND CAROTID DISEASE [J].
GROSSET, DG ;
GEORGIADIS, D ;
KELMAN, AW ;
LEES, KR .
STROKE, 1993, 24 (12) :1922-1924
[7]   DETECTION OF MIDDLE CEREBRAL EMBOLI DURING CORONARY-ARTERY BYPASS-SURGERY USING TRANSCRANIAL DOPPLER SONOGRAPHY [J].
HARRISON, MJG ;
PUGSLEY, W ;
NEWMAN, S ;
PASCHALIS, C ;
KLINGER, L ;
TREASURE, T ;
ASPEY, B .
STROKE, 1990, 21 (10) :1512-1512
[8]   Multigated Doppler ultrasound in the detection of emboli in a flow model and embolic signals in patients [J].
Molloy, J ;
Markus, HS .
STROKE, 1996, 27 (09) :1548-1552
[9]   THE DETECTION OF MICROEMBOLI IN THE MIDDLE CEREBRAL-ARTERY DURING CARDIOPULMONARY BYPASS - A TRANSCRANIAL DOPPLER ULTRASOUND INVESTIGATION USING MEMBRANE AND BUBBLE OXYGENATORS [J].
PADAYACHEE, TS ;
PARSONS, S ;
THEOBOLD, R ;
LINLEY, J ;
GOSLING, RG ;
DEVERALL, PB .
ANNALS OF THORACIC SURGERY, 1987, 44 (03) :298-302
[10]   THE IMPACT OF MICROEMBOLI DURING CARDIOPULMONARY BYPASS ON NEUROPSYCHOLOGICAL FUNCTIONING [J].
PUGSLEY, W ;
KLINGER, L ;
PASCHALIS, C ;
TREASURE, T ;
HARRISON, M ;
NEWMAN, S .
STROKE, 1994, 25 (07) :1393-1399