Ultrahigh resolution optical coherence tomography using a superluminescent light source

被引:70
作者
Kowalevicz, AM [1 ]
Ko, T
Hartl, I
Fujimoto, JG
Pollnau, M
Salathé, RP
机构
[1] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
[2] MIT, Elect Res Lab, Cambridge, MA 02139 USA
[3] Swiss Fed Inst Technol, Inst Appl Opt, Dept Microtech, CH-1015 Lausanne, Switzerland
[4] Harvard Univ, Div Engn & Appl Sci, Cambridge, MA 02138 USA
来源
OPTICS EXPRESS | 2002年 / 10卷 / 07期
关键词
D O I
10.1364/OE.10.000349
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A superluminescent Ti: Al2O3 crystal is demonstrated as a light source for ultrahigh resolution optical coherence tomography (OCT). Single spatial mode, fiber coupled output powers of similar to40 muW can be generated with 138 nm bandwidth using a 5 W frequency doubled, diode pumped laser, pumping a thin Ti: Al2O3 crystal. Ultrahigh resolution OCT imaging is demonstrated with 2.2 mum axial resolution in air, or 1.7 mum in tissue, with >86 dB sensitivity. This light source provides a simple and robust alternative to femtosecond lasers for ultrahigh resolution OCT imaging. (C) 2002 Optical Society of America.
引用
收藏
页码:349 / 353
页数:5
相关论文
共 12 条
[1]   Ti:sapphire planar waveguide laser grown by pulsed laser deposition [J].
Anderson, AA ;
Eason, RW ;
Hickey, LMB ;
Jelinek, M ;
Grivas, C ;
Gill, DS ;
Vainos, NA .
OPTICS LETTERS, 1997, 22 (20) :1556-1558
[2]   In vivo cellular optical coherence tomography imaging [J].
Boppart, SA ;
Bouma, BE ;
Pitris, C ;
Southern, JF ;
Brezinski, ME ;
Fujimoto, JG .
NATURE MEDICINE, 1998, 4 (07) :861-865
[3]   HIGH-RESOLUTION OPTICAL COHERENCE TOMOGRAPHIC IMAGING USING A MODE-LOCKED TI-AL2O3 LASER SOURCE [J].
BOUMA, B ;
TEARNEY, GJ ;
BOPPART, SA ;
HEE, MR ;
BREZINSKI, ME ;
FUJIMOTO, JG .
OPTICS LETTERS, 1995, 20 (13) :1486-1488
[4]   Self-phase-modulated Kerr-lens mode-locked Cr:forsterite laser source for optical coherence tomography [J].
Bouma, BE ;
Tearney, GJ ;
Bilinsky, IP ;
Golubovic, B ;
Fujimoto, JG .
OPTICS LETTERS, 1996, 21 (22) :1839-1841
[5]   OPTICAL LOW COHERENCE REFLECTOMETRY WITH 1-BULLET-9 MU-M SPATIAL-RESOLUTION [J].
CLIVAZ, X ;
MARQUISWEIBLE, F ;
SALATHE, RP .
ELECTRONICS LETTERS, 1992, 28 (16) :1553-1555
[6]   In vivo ultrahigh-resolution optical coherence tomography [J].
Drexler, W ;
Morgner, U ;
Kärtner, FX ;
Pitris, C ;
Boppart, SA ;
Li, XD ;
Ippen, EP ;
Fujimoto, JG .
OPTICS LETTERS, 1999, 24 (17) :1221-1223
[7]   Ultrahigh-resolution ophthalmic optical coherence tomography [J].
Drexler, W ;
Morgner, U ;
Ghanta, RK ;
Kärtner, FX ;
Schuman, JS ;
Fujimoto, JG .
NATURE MEDICINE, 2001, 7 (04) :502-507
[8]   Ultrahigh-resolution optical coherence tomography using continuum generation in an air-silica microstructure optical fiber [J].
Hartl, I ;
Li, XD ;
Chudoba, C ;
Ghanta, RK ;
Ko, TH ;
Fujimoto, JG ;
Ranka, JK ;
Windeler, RS .
OPTICS LETTERS, 2001, 26 (09) :608-610
[9]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[10]   SPATIALLY COHERENT WHITE-LIGHT INTERFEROMETER BASED ON A POINT FLUORESCENT SOURCE [J].
LIU, HH ;
CHENG, PH ;
WANG, JP .
OPTICS LETTERS, 1993, 18 (09) :678-680