Quality assessment of defibrillation and advanced life support using data from the medical control module of the defibrillator

被引:77
作者
Sunde, K [1 ]
Eftestol, T [1 ]
Askenberg, C [1 ]
Steen, PA [1 ]
机构
[1] Norwegian Air Ambulance, Dept Res & Educ Acute Med, N-1441 Drobak, Norway
关键词
out-of-hospital CPR; advanced life support; utstein style; emergency medical services; shock; quality; outcome;
D O I
10.1016/S0300-9572(99)00059-3
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
What actually occurred during the two last links in the 'chain of survival: defibrillation and advanced life support (ALS), was studied in 156 patients with cardiac arrest of cardiac aetiology using the computer recording of the defibrillator and the Utstein-style data record. Ten patients (6%) survived. The ECG artefacts caused by chest compressions enabled a detailed analysis of compression rates (median 108 min(-1)) and duration of important compression free periods. The time from initiation of monitoring during asystole until chest compressions were initiated was median 29 s, significantly shorter than during electromechanical dissociation (EMD, 109 s; P < 0.001). These times were both significantly longer than the median time from initiation of monitoring until the first shock was given in cases with VF (19 s; P < 0.001), A total of 883 shocks (median six shocks) were administered to 110 patients with a significant difference in number of shocks between survivors and non-survivors, one versus seven, respectively. The success rate for the first shock and all shocks defined as non-VT/VF 5 s after the shock, was 75 and 63%, respectively. However, just 10% of all shocks resulted in a rhythm with a pulse and only 4% resulted in sustained return of spontaneous circulation (ROSC). An isoelectric period followed 38% of the shocks, and in 27% this lasted more than 20 s, with five patients obtaining electrical activity with a pulse after more than 30 s of isoelectric EGG. Thoracic impedance did not affect the shuck efficacy. The method of analysing resuscitation we describe may be useful for quality improvement. (C) 1999 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:237 / 247
页数:11
相关论文
共 34 条
[21]   The 1998 European Resuscitation Council guidelines for adult advanced life support - A statement from the Working Group on Advanced Life Support, and approved by the executive committee of the European Resuscitation Council [J].
Robertson, C ;
Steen, P ;
Adgey, J ;
Bossaert, L ;
Carli, P ;
Chamberlain, D ;
Dick, W ;
Ekstrom, L ;
Hapnes, SA ;
Holmberg, S ;
Juchems, R ;
Kette, F ;
Koster, R ;
de Latorre, FJ ;
Lindner, K ;
Perales, N .
RESUSCITATION, 1998, 37 (02) :81-90
[22]   IMPORTANCE OF THE DURATION OF INADEQUATE CORONARY PERFUSION-PRESSURE ON RESUSCITATION FROM CARDIAC-ARREST [J].
SANDERS, AB ;
KERN, KB ;
ATLAS, M ;
BRAGG, S ;
EWY, GA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 6 (01) :113-118
[23]   Adverse effects of interrupting precordial compression during cardiopulmonary resuscitation [J].
Sato, Y ;
Weil, MH ;
Sun, SJ ;
Tang, WC ;
Xie, JL ;
Noc, M ;
Bisera, J .
CRITICAL CARE MEDICINE, 1997, 25 (05) :733-736
[24]   QUALITY OF ON-SITE PERFORMANCE IN PREHOSPITAL ADVANCED CARDIAC LIFE-SUPPORT (ACLS) [J].
SCHNEIDER, T ;
MAUER, D ;
DIEHL, P ;
EBERLE, B ;
DICK, W .
RESUSCITATION, 1994, 27 (03) :207-213
[25]   PERFORMANCE OF AN ESTABLISHED SYSTEM OF 1ST RESPONDER OUT-OF-HOSPITAL DEFIBRILLATION - THE RESULTS OF THE 2ND YEAR OF THE HEARTSTART SCOTLAND PROJECT IN THE UTSTEIN STYLE [J].
SEDGWICK, ML ;
DALZIEL, K ;
WATSON, J ;
CARRINGTON, DJ ;
COBBE, SM .
RESUSCITATION, 1993, 26 (01) :75-88
[26]   EFFICACY OF OUT OF HOSPITAL DEFIBRILLATION BY AMBULANCE TECHNICIANS USING AUTOMATED EXTERNAL DEFIBRILLATORS - THE HEARTSTART-SCOTLAND PROJECT [J].
SEDGWICK, ML ;
WATSON, J ;
DALZIEL, K ;
CARRINGTON, DJ ;
COBBE, SM .
RESUSCITATION, 1992, 24 (01) :73-87
[27]   PROSPECTIVE VALIDATION OF A NEW MODEL FOR EVALUATING EMERGENCY MEDICAL-SERVICES SYSTEMS BY IN-FIELD OBSERVATION OF SPECIFIC TIME INTERVALS IN PREHOSPITAL CARE [J].
SPAITE, DW ;
VALENZUELA, TD ;
MEISLIN, HW ;
CRISS, EA ;
HINSBERG, P .
ANNALS OF EMERGENCY MEDICINE, 1993, 22 (04) :638-645
[28]   Quality of mechanical, manual standard and active compression-decompression CPR on the arrest site and during transport in a manikin model [J].
Sunde, K ;
Wik, L ;
Steen, PA .
RESUSCITATION, 1997, 34 (03) :235-242
[29]   SURVEY OF 3765 CARDIOPULMONARY RESUSCITATIONS IN BRITISH HOSPITALS (THE BRESUS STUDY) - METHODS AND OVERALL RESULTS [J].
TUNSTALLPEDOE, H ;
BAILEY, L ;
CHAMBERLAIN, DA ;
MARSDEN, AK ;
WARD, ME ;
ZIDEMAN, DA .
BRITISH MEDICAL JOURNAL, 1992, 304 (6838) :1347-1351
[30]  
VERSCHUEREN H, 1998, RESUSCITATION, V37, pS15