Quantification of lactate in synovia by microchip with contactless conductivity detection

被引:22
作者
Song, Zhirui [1 ]
Xu, Yue [2 ]
Chen, Zuanguang [1 ]
Yang, Jianping [1 ]
Li, Xinchun [1 ]
Zhang, Zhiguang [2 ]
机构
[1] Sun Yat Sen Univ, Sch Pharmaceut Sci, Guangzhou 510006, Guangdong, Peoples R China
[2] Sun Yat Sen Univ, Guanghua Sch Stomatol, Guangzhou 510055, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Microchip; Capillary electrophoresis; Contactless conductivity detection; Synovia; Lactate; CAPILLARY-ELECTROPHORESIS; LACTIC-ACID; AMPEROMETRIC BIOSENSOR; DIAGNOSIS; OXIDASE; PLASMA; SENSOR; GLASS; CHIP; HPLC;
D O I
10.1016/j.ab.2012.11.006
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This article describes the determination of lactate in synovia by microchip capillary electrophoresis (MCE) integrated with contactless conductivity detection (CCD). The optimal running buffer consists of 10 mM tris(hydroxymethyl)aminomethane, 1 mM HCl, and 0.1 mM hexadecyltrimethylammonium bromide (pH 9.1). The quantitative measurement of lactate in dilute synovia samples can be finished in less than 40 s. The results indicated that the peak area had a good linear relationship with lactate concentration in the range of 20 to 1000 mu M, and the correlation coefficient was 0.9984. The average recovery was from 96.6% to 106.1%, and the interday relative standard deviation was less than 4.0% (n = 6). The limit of detection (signal/noise = 3) reached 6.5 mu M. To validate the assay results, we compared the current method with the high-performance liquid chromatography method by measuring lactate in synovia samples. The data analysis verified that there was no significant difference between the two methods. Due to significant features such as low cost, integration, and miniaturization, the MCE CCD method may have great potential in clinical diagnosis. (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:73 / 77
页数:5
相关论文
共 32 条
[21]   Quantification of plasma lactate concentrations using capillary electrophoresis with contactless conductivity detection [J].
Pormsila, Worapan ;
Morand, Rejane ;
Kraehenbuehl, Stephan ;
Hauser, Peter C. .
ELECTROPHORESIS, 2011, 32 (08) :884-889
[22]   Determination of lactate or oxalate using injected lactate oxidase and peroxidase by capillary electrophoresis with UV detection [J].
Qi, LN ;
Danielson, ND .
ELECTROPHORESIS, 2003, 24 (12-13) :2070-2075
[23]   Amperometric Biosensor for Direct Blood Lactate Detection [J].
Ricardo Romero, Marcelo ;
Ahumada, Facundo ;
Garay, Fernando ;
Baruzzi, Ana M. .
ANALYTICAL CHEMISTRY, 2010, 82 (13) :5568-5572
[24]   SYNOVIAL-FLUID LACTIC-ACID MEASUREMENT IN THE DIAGNOSIS AND MANAGEMENT OF SEPTIC ARTHRITIS [J].
RIORDAN, T ;
DOYLE, D ;
TABAQCHALI, S .
JOURNAL OF CLINICAL PATHOLOGY, 1982, 35 (04) :390-394
[25]   Determination of creatine and phosphocreatine in muscle biopsy samples by capillary electrophoresis with contactless conductivity detection [J].
See, Hong Heng ;
Schmidt-Marzinkowski, Julia ;
Pormsila, Worapan ;
Morand, Rejane ;
Kraehenbuehl, Stephan ;
Hauser, Peter C. .
ANALYTICA CHIMICA ACTA, 2012, 727 :78-82
[26]   α-MoO3 nanowire-based amperometric biosensor for l-lactate detection [J].
Shakir, Imran ;
Shahid, Muhammad ;
Yang, Hyoung Woo ;
Cherevko, Serhiy ;
Chung, Chan-Hwa ;
Kang, Dae Joon .
JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2012, 16 (06) :2197-2201
[27]   A NONENZYMATIC METHOD FOR THE DETERMINATION OF PICOMOLE AMOUNTS OF LACTATE USING HPLC - ITS APPLICATION TO SINGLE MUSCLE-FIBERS [J].
SIMONIDES, WS ;
ZAREMBA, R ;
VANHARDEVELD, C ;
VANDERLAARSE, WJ .
ANALYTICAL BIOCHEMISTRY, 1988, 169 (02) :268-273
[28]   Capillary and microchip electrophoresis of basic drugs with contactless conductivity detection [J].
Tanyanyiwa, J ;
Hauser, PC .
ELECTROPHORESIS, 2004, 25 (17) :3010-3016
[29]   An integrated microfluidic array system for evaluating toxicity and teratogenicity of drugs on embryonic zebrafish developmental dynamics [J].
Yang, Fan ;
Chen, Zuanguang ;
Pan, Jianbin ;
Li, Xinchun ;
Feng, Jun ;
Yang, Hui .
BIOMICROFLUIDICS, 2011, 5 (02)
[30]   A practical glucose biosensor based on Fe3O4 nanoparticles and chitosan/nafion composite film [J].
Yang, Liuqing ;
Ren, Xiangling ;
Tang, Fangqiong ;
Zhang, Lin .
BIOSENSORS & BIOELECTRONICS, 2009, 25 (04) :889-895