Determination of opiates and cocaine in hair using automated enzyme immunoassay screening methodologies followed by gas chromatographic-mass spectrometric (GC-MS) confirmation

被引:71
作者
Lachenmeier, Katrin [1 ]
Musshoff, Frank [1 ]
Madea, Burkhard [1 ]
机构
[1] Univ Bonn, Inst Legal Med, D-53111 Bonn, Germany
关键词
drugs-of-abuse; hair analysis; immunological screening; enzyme-linked immunosorbent assay; gas chromatography-mass spectrometry;
D O I
10.1016/j.forsciint.2005.08.009
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
The objective of this study was to develop a two-step strategy for analysis of opiates and cocaine in hair samples involving an immunological screening procedure followed by confirmation of results using gas chromatography-mass spectrometry (GCMS). A semi-quantitative automated competitive enzyme-linked immunosorbent assay (ELISA) methodology using Oral Fluid Micro-Plate Enzyme Immunoassays (Orasure Technologies, Inc.) was developed and validated. Applicability was proven by analysis of authentic head hair samples from drug users (n = 103) and from opiate associated fatalities (n = 21). The optimum cutoff values for the ELISA tests were 0.1 ng cocaine-equivalents/mg hair and 0.05 ng morphine-equivalents/mg hair using a 50 mg hair sample. Both ELISA tests had a sensitivity of 100%, the specificity was 66% for cocaine-equivalents and 42% for morphine-equivalents. The intruassay precision was 11% for the cocaine and 3% for the opiates ELISA, while interassay precision was 12% for the cocaine and 4% for the opiates ELISA test. The actual analyte concentrations in the hair samples were determined using GC-MS and were between 0.04 and 5.20 ng/mg for heroin (HER), between 0.04 and 30.01 ng/mg for 6-monoacetylomorphine (MAM), between 0.03 and 11.87 ng/mg for morphine (MOR), between 0:02 and 1.84 ng/mg for codeine (COD), between 0.02 and 2.48 ng/mg for acetylcodeine (AC), between 0.01 and 21.37 ng/mg for cocaine (COC), between 0.03 and 10.51 ng/mg for benzoylecgonine (BE) and between 0.05 and 1.26 ng/mg for cocaethylene (CE). The automated ELISA tests were proven to be valid screening procedures for the detection of cocaine and opiates in hair as confirmed by GC-MS. Screening methods provide rapid and inexpensive automated pre-test procedures to detect drugs in hair or other matrices. For forensic purposes screening therefore represents an ideal complement to routinely applied GC-MS procedures. (c) 2005 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:189 / 199
页数:11
相关论文
共 31 条
[21]  
SACHS H, 1989, J CLIN CHEM CLIN BIO, V27, P873
[22]  
SACHS H, P WORKSH 2002 SOC HA
[23]  
*SAMSHA, 2005, MAND GUID FED WORKPL
[24]  
Schmitt G., 2003, METHODENVALIDIERUNG
[25]   Immunological screening of drugs of abuse and gas chromatographic mass spectrometric confirmation of opiates and cocaine in hair [J].
Segura, D ;
Stramesi, C ;
Redón, A ;
Ventura, M ;
Sanchez, CJ ;
González, G ;
San, L ;
Montagna, M .
JOURNAL OF CHROMATOGRAPHY B, 1999, 724 (01) :9-21
[26]   Hair analysis by immunological methods from the beginning to 2000 [J].
Spiehler, V .
FORENSIC SCIENCE INTERNATIONAL, 2000, 107 (1-3) :249-259
[27]   Validation of an automated microplate enzyme immunoassay for screening of postmortem blood for drugs of abuse [J].
Spiehler, VR ;
Collison, IB ;
Sedgwick, PR ;
Perez, SL ;
Le, SD ;
Farnin, DA .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1998, 22 (07) :573-579
[28]   SEGMENTAL HAIR ANALYSIS FOR COCAINE AND HEROIN ABUSE DETERMINATION [J].
STRANOROSSI, S ;
BERMEJOBARRERA, A ;
CHIAROTTI, M .
FORENSIC SCIENCE INTERNATIONAL, 1995, 70 (1-3) :211-216
[29]   Amphetamines in hair by enzyme-linked immunosorbent assay [J].
Sweeney, SA ;
Kelly, RC ;
Bourland, JA ;
Johnson, T ;
Brown, WC ;
Lee, H ;
Lewis, E .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1998, 22 (06) :418-424
[30]   Hair analysis by using radioimmunoassay, high-performance liquid chromatography and capillary electrophoresis to investigate chronic exposure to heroin, cocaine and/or ecstasy in applicants for driving licences [J].
Tagliaro, F ;
Valentini, R ;
Manetto, G ;
Crivellente, F ;
Carli, G ;
Marigo, M .
FORENSIC SCIENCE INTERNATIONAL, 2000, 107 (1-3) :121-128