A linear array silicon pixel detector: images of a mammographic test object and evaluation of delivered doses

被引:16
作者
Arfelli, F
Bonvicini, V
Bravin, A
Cantatore, G
Castelli, E
DallaPalma, L
DiMichiel, M
Longo, R
Olivo, A
Pani, S
Pontoni, D
Poropat, P
Prest, M
Rashevsky, A
Tromba, G
Vacchi, A
机构
[1] UNIV TRIESTE,DIPARTMENTO FIS,I-34127 TRIESTE,ITALY
[2] IST NAZL FIS NUCL,I-34127 TRIESTE,ITALY
[3] SOC SINCROTRONE,I-34012 TRIESTE,ITALY
[4] UNIV TRIESTE,OSPED CATTINARA,IST RADIOL,I-34100 TRIESTE,ITALY
关键词
D O I
10.1088/0031-9155/42/8/007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We present images of a mammographic test object obtained using a linear array silicon pixel detector capable of single-photon counting. The detector pixel size was 200 x 300 mu m(2) and images were acquired by scanning the test object between the laminar detector and the x-ray source with a scanning step of 100 mu m. A molybdenum anode tube was used with two different filtrations: 2 mm aluminium and 25 mu m molybdenum. Conventional film-screen images were also obtained in order to compare spatial and contrast resolution. In our digital images it is possible to recognize low-contrast details having dimensions smaller than or equal to the dimensions of details visible by means of a clinical mammographic unit. The detection of microcalcifications smaller than 150 mu m was possible only when using the Mo filtration. However a copper wire of 50 mu m diameter was detectable when embedded in a simulated tissue. We discuss in detail the mean glandular doses (MGDs) delivered during the image acquisition. The MGDs necessary to obtain good-quality images are always smaller than at a conventional mammographic unit. Since MGDs depend on the x-ray spectrum, the dose reduction becomes larger when the applied spectrum is harder than in film-screen acquisition (Al filtration and 35 kVp).
引用
收藏
页码:1565 / 1573
页数:9
相关论文
共 20 条
[1]   A REAL-TIME, FLAT-PANEL, AMORPHOUS-SILICON, DIGITAL X-RAY IMAGER [J].
ANTONUK, LE ;
YORKSTON, J ;
HUANG, WD ;
SIEWERDSEN, JH ;
BOUDRY, JM ;
ELMOHRI, Y ;
MARX, MV .
RADIOGRAPHICS, 1995, 15 (04) :993-1000
[2]   New developments in the field of silicon detectors for digital radiology [J].
Arfelli, F ;
Barbiellini, G ;
Bonvicini, V ;
Cantatore, G ;
Castelli, E ;
DiMichiel, M ;
Longo, R ;
Olivo, A ;
Poropat, P ;
Prest, M ;
Tomasini, F ;
Tromba, G ;
Vacchi, A ;
Zampa, N .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 377 (2-3) :508-513
[3]   SILICON X-RAY-DETECTOR - FOR SYNCHROTRON-RADIATION DIGITAL RADIOLOGY [J].
ARFELLI, F ;
BARBIELLINI, G ;
CANTATORE, G ;
CASTELLI, E ;
CRISTAUDO, P ;
DALLAPALMA, L ;
DIMICHIEL, M ;
LONGO, R ;
POROPAT, P ;
ROSEI, R ;
SESSA, M ;
TOMASINI, F ;
TROMBA, G ;
VACCHI, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 353 (1-3) :366-370
[4]   Silicon detectors for digital radiography [J].
Arfelli, F ;
Barbiellini, G ;
Bonvicini, V ;
Bravin, A ;
Cantatore, G ;
Castelli, E ;
dallaPalma, L ;
diMichiel, M ;
Longo, R ;
Olivo, A ;
Poropat, P ;
Prest, M ;
Rosei, R ;
Savoia, A ;
Sessa, M ;
Tomasini, F ;
Tromba, G ;
Vacchi, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 367 (1-3) :48-53
[5]   CASTOR a VLSI CMOS mixed analog-digital circuit for low noise multichannel counting applications [J].
Comes, G ;
Loddo, F ;
Hu, Y ;
Kaplon, J ;
Ly, F ;
Turchetta, R ;
Bonvicini, V ;
Vacchi, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 377 (2-3) :440-445
[6]   OPTIMIZATION OF SPECTRAL SHAPE IN DIGITAL MAMMOGRAPHY - DEPENDENCE ON ANODE MATERIAL, BREAST THICKNESS, AND LESION TYPE [J].
FAHRIG, R ;
YAFFE, MJ .
MEDICAL PHYSICS, 1994, 21 (09) :1473-1481
[7]   IMAGING PERFORMANCE OF A DIGITAL STORAGE PHOSPHOR SYSTEM [J].
HILLEN, W ;
SCHIEBEL, U ;
ZAENGEL, T .
MEDICAL PHYSICS, 1987, 14 (05) :744-751
[8]   IMAGING OF THE RADIOGRAPHICALLY DENSE BREAST [J].
JACKSON, VP ;
HENDRICK, RE ;
FEIG, SA ;
KOPANS, DB .
RADIOLOGY, 1993, 188 (02) :297-301
[9]  
JENNINGS RJ, 1993, SPIE P, V1896, P259
[10]  
KARELLAS A, 1992, MED PHYS, V19, P115